Toshiba VF-MB1/S15 instruction manual ZSW Status Word Data, Bit Valure Name

Page 13

E6581738

3.3.ZSW Status Word Data

Bit

Valure

Name

Note

 

 

 

 

0

1

Ready To Switch-on

Power supply is switched on

0

Not Ready To Switch-on

-

 

 

 

 

 

1

1

Ready To Operate

Refer to control word, bit 1.

0

Not Ready To Operate

-

 

 

 

 

 

 

1

Operation Enabled

Drive follows setpoint.

2

(Refer to control word 1, bit 3)

 

 

0

Operation Disabled

-

 

 

 

 

 

3

1

Fault Present

VF-MB1/S15 tripped.

0

No Fault

VF-MB1/S15 is not tripped.

 

 

 

 

 

4

1

Coast Stop Not Activated

-

0

Coast Stop Activated (OFF 2)

"Coast Stop (OFF 2)" command is present.

 

 

 

 

 

5

1

Quick Stop Not Activated

-

0

Quick Stop Activated (OFF 3)

"Quick Stop (OFF 3)" command is present

 

 

 

 

 

 

1

Switching On Inhibited

Control word bit1 or 2 is set to 0

6

or fault trip has been acknowledged.

 

 

0

Switching On Not Inhibited

-

 

 

 

 

 

 

1

Warning Present

Drive still operational: Alarm in service parameter: No

7

acknowledgement.

 

 

0

No Warning

Alarm not present or alarm has disappeared again

 

 

 

 

 

 

1

Speed Error

Refer to section 3.3.1.

8

Within Tolerance Range

 

0

Speed Error

 

 

 

 

Out Of Tolerance Range

 

 

 

 

9

1

Control Requested

VF-MB1/S15 is controlled by PROFIBUS master.

0

No Control Requested

VF-MB1/S15 is controlled by another interface.

 

 

 

 

 

10

1

f Or n Reached Or Exceeded

Actual value ≥ Comparison value (setpoint)

0

f Or n Not Reached

-

 

 

 

 

 

11

----

Device-specification

(Reserved.)

 

 

 

 

12

----

Device-specification

(Reserved.)

 

 

 

 

13

----

Device-specification

(Reserved.)

 

 

 

 

14

----

Device-specification

(Reserved.)

 

 

 

 

15

----

Device-specification

(Reserved.)

 

 

 

 

- 11 -

Image 13
Contents Tosvert VF-MB1/S15 Contents Introduction Safety precautions E6581738 E6581738 E6581738 Connection Information Exterior featuresDX Data exchange Green LED Status indicatorVF-MB1/S15 Communication parameters Telegram ProfileSTW Control Word Data PDP003Z supports only speed control mode Bit Value NameBit Valure Name ZSW Status Word Data15s 20s 25s 30s Setpoint Actual valueTmax ZSW BitState Machine Example 1 Hz Forward running and Deceleration stop AK Request from Master to PDP003Z) Access to the Profibus parameterProfibus parameter PNU Value Mode13 9A Example 1. Reading the PNU 922 TelegramAccess to VF-MB1/S15 parameter Response Value 0x03E8 = 1000 10.00Hz Vendor Spec. Profile Profibus Master How to useBit Function Overview of the VF-MB1/S15 parameter2. fa23 Communication command Specified data output ST=ON ST=OFF E6581738 RES RY-RC Diagnostic Master DP-V1 functionProfibs DP-V1 Communication VF-MB1/S15Example1. Read the PROFIdrive parameter 0x02 Example 2. Change the PROFIdrive parameter0x9F 0x820xE8 Example 3. Read the VF-MB1/S15 parameter0xFD 0x310x30 Example 4. Change the VF-MB1/S15 parameter0x07 GSD file Profibus Local/Remote OperationFunction number Appendix