4.2.12.fc91 (Alarm code)

bit

Function

0

1

Remarks

(Code displayed on

the panel)

0

Over-current alarm

Normal

Alarming

c flicking

1

Inverter over load alarm

Normal

Alarming

l flicking

2

Motor over load alarm

Normal

Alarming

l flicking

3

Over heat alarm

Normal

Alarming

h flicking

4

Over voltage alarm

Normal

Alarming

p flicking

5

Main circuit undervoltage alarm

Normal

Alarming

-

6

main device overheat alarm

Normal

Alarming

l flicking

7

Under current alarm

Normal

Alarming

-

8

Over-torque alarm

Normal

Alarming

-

9

Braking resistor overload alarm

Normal

Alarming

-

10

Cumulative operation hours alarm

Normal

Alarming

-

11

Option communication alarm

Normal

Alarming

-

12

Serial communication alarm

Normal

Alarming

-

13

MOFFMS (MSrelay off or MOFF)

Normal

Alarming

-

14

Stop after instantaneous power off

-

Dec., Under

Refer to f302

stop

value

 

 

 

15

Stop after LL continuance time

-

Dec., Under

Refer to f256

stop

value

 

 

 

4.2.13.fd06 (Input TB Status)

bit

TB Name

Function (Parameter)

0

1

0F Input terminal function selection 1 (f111)

1R Input terminal function selection 2 (f112)

2

RES

Input terminal function selection 3 (f113)

 

 

3

S1

Input terminal function selection 4 (f114)

OFF

ON

4

S2

Input terminal function selection 5 (f115)

 

 

5

S3

Input terminal function selection 6 (f116)

 

 

6

VIB*1

Input terminal function selection 7 (f117)

 

 

7

VIA*1

Input terminal function selection 8 (f118)

 

 

5 to 15

(Undefined)

-

-

-

Note: The bit described "Undefined" is unstable. Do not use the bit for the judgment.

*1: VIA/ VIB are input terminal function when f109 is logic input. *The input terminal function is selected by each parameter.

- 27 -

Image 29
Contents Tosvert VF-MB1/S15 Contents Introduction Safety precautions E6581738 E6581738 E6581738 Connection Information Exterior featuresDX Data exchange Green LED Status indicatorVF-MB1/S15 Communication parameters Telegram ProfileSTW Control Word Data PDP003Z supports only speed control mode Bit Value NameBit Valure Name ZSW Status Word Data15s 20s 25s 30s Setpoint Actual valueTmax ZSW BitState Machine Example 1 Hz Forward running and Deceleration stop AK Request from Master to PDP003Z) Access to the Profibus parameterProfibus parameter PNU Value Mode13 9A Example 1. Reading the PNU 922 TelegramAccess to VF-MB1/S15 parameter Response Value 0x03E8 = 1000 10.00Hz Vendor Spec. Profile Profibus Master How to useBit Function Overview of the VF-MB1/S15 parameter2. fa23 Communication command Specified data output ST=ON ST=OFF E6581738 RES RY-RC Diagnostic Master DP-V1 functionProfibs DP-V1 Communication VF-MB1/S15Example1. Read the PROFIdrive parameter 0x02 Example 2. Change the PROFIdrive parameter0x9F 0x820xE8 Example 3. Read the VF-MB1/S15 parameter0xFD 0x310x07 Example 4. Change the VF-MB1/S15 parameter0x30 GSD file Profibus Local/Remote OperationFunction number Appendix