3.2.STW Control Word Data
PDP003Z supports only speed control mode.
Bit | Value | Name | Note | |
|
|
|
| |
0 | 1 | ON | “Switched on” condition | |
0 | OFF | Normal stop. | ||
| ||||
|
|
|
| |
1 | 1 | No Coast Stop | All "Coast Stop (OFF2)" commands are withdrawn | |
0 | Coast Stop (OFF 2) | Coast stop. | ||
| ||||
|
|
|
| |
2 | 1 | No Quick Stop | All "Quick Stop (OFF3)" commands are withdrawn. | |
0 | Quick Stop (OFF 3) | Quick Stop | ||
| ||||
|
|
|
| |
3 | 1 | Enable Operation | The drive then | |
0 | Disable Operation | Normal stop. | ||
| ||||
|
|
|
| |
4 | 1 | Enable Ramp Generator | - | |
0 | Reset Ramp Generator | Output of the RFG is set to 0. | ||
| ||||
|
|
|
| |
5 | 1 | Unfreeze Ramp Generator | - | |
0 | Freeze Ramp Generator | Freeze the actual setpoint entered by the RFG *. | ||
| ||||
|
|
|
| |
6 | 1 | Enable Setpoint | The value selected at the input of the RFG is | |
0 | Disable Setpoint | The value selected at the input of the RFG is set to 0. | ||
| ||||
|
|
|
| |
7 | 1 | Fault Acknowledge | Fault reset (0 | |
0 | No meaning | - | ||
| ||||
|
|
|
| |
8 | 1 | JOG 1 ON ** | ||
0 | JOG 1 OFF | Jogging stop, if "JOG 1" was previously ON. Stop drive | ||
| ||||
| according to | |||
|
|
| ||
9 | 1 | JOG 2 ON ** | ||
0 | JOG 2 OFF | Jogging stop, if "JOG 2" was previously ON. Stop drive | ||
| ||||
| according to | |||
|
|
| ||
10 | 1 | Control By PLC | The control word and main setpoint are activated. | |
0 | No Control By PLC | The control word and main setpoint are inactivated. | ||
| ||||
|
|
|
| |
11 | (Reserved.) | |||
|
|
|
| |
12 | 1 | Net Control | PDP003Z control is enabled. | |
|
|
| ||
| 0 | Local Control | PDP003Z control is disabled. | |
|
|
|
| |
13 | 1 | Net Reference | PDP003Z reference is enabled. | |
0 | Local Reference | PDP003Z reference is disabled. | ||
| ||||
|
|
|
| |
14 | (Reserved.) | |||
|
|
|
| |
15 | (Reserved.) | |||
|
|
|
|
*RFG: Ramp Function Generator
**Operation is enabled, drive is in standstill and STW1 bit 4, 5, 6 = 0.