Wiring

Warning

Mandatory

Shut off power when installing and wiring this option.

Wait at least 15 minutes and check to make sure that the charge lamp (VF- MB1/S15) is no longer lit.

Electrical construction work must be done by a qualified expert.

Installation or connection of input power by someone who does not have that expert knowledge may result in fire or electric shock.

Operations

Warning

Prohibited

Do not touch switches when the hands are wet and do not try to clean the drive with a damp cloth.

Doing so could result in electric shock.

Do not pull on any cable it self.

Doing so could result in damage or malfunction.

Cautions for the communication

Warning

Do not set the value that exceeds an effective range as data.

Prohibited

The motor may suddenly restart or stop and that could result in injury.

 

 

 

 

▼ Check PROFIBUS state (using below status word bit) when the option unit is

Mandatory

deactivated by an unusual event such as an operating error, power outage, failure, etc.

- ZSW Status Word Bit 3 (Fault), Bt 7 (Warning)

 

 

(The communication error occurs when "1" as value or this value cannot be read.)

 

Deactivated option unit may cause an accident, if the PROFIBUS state is not checked.

Make sure that the operation signals are STOP before clearing the drive’s fault. The motor may suddenly start and that may result in injuries.

Disposal

Caution

Mandatory

For safety's sake, do not dispose of the disused drive yourself but ask an industrial waste disposal agent (*).

If the collection, transport and disposal of industrial waste is done by someone who is not licensed for that job, it is a punishable violation of the law. (Laws in regard to cleaning and processing of waste materials)

(*) Persons who specialize in the processing of waste and known as “industrial waste product collectors and transporters” or “industrial waste disposal persons.”

- 4 -

Image 6
Contents Tosvert VF-MB1/S15 Contents Introduction Safety precautions E6581738 E6581738 E6581738 Exterior features Connection InformationStatus indicator DX Data exchange Green LEDVF-MB1/S15 Communication parameters Profile TelegramPDP003Z supports only speed control mode Bit Value Name STW Control Word DataZSW Status Word Data Bit Valure NameTmax Setpoint Actual value15s 20s 25s 30s ZSW BitState Machine Example 1 Hz Forward running and Deceleration stop Access to the Profibus parameter AK Request from Master to PDP003Z)Value Mode Profibus parameter PNUExample 1. Reading the PNU 922 Telegram 13 9AAccess to VF-MB1/S15 parameter Response Value 0x03E8 = 1000 10.00Hz Vendor Spec. Profile How to use Profibus MasterOverview of the VF-MB1/S15 parameter Bit Function2. fa23 Communication command Specified data output ST=ON ST=OFF E6581738 RES RY-RC Diagnostic Profibs DP-V1 Communication DP-V1 functionMaster VF-MB1/S15Example1. Read the PROFIdrive parameter 0x9F Example 2. Change the PROFIdrive parameter0x02 0x820xFD Example 3. Read the VF-MB1/S15 parameter0xE8 0x31Example 4. Change the VF-MB1/S15 parameter 0x300x07 Profibus Local/Remote Operation GSD fileAppendix Function number