Toshiba instruction manual Example 3. Read the VF-MB1/S15 parameter, 0xE8, 0xFD, 0x31, 0xEC

Page 35

E6581738

6.3.Example 3. Read the VF-MB1/S15 parameter

When access to VF-MB1/S15 parameter, set “1000” to the PNU.

6.3.1.Write Request data table (Read fd04 (Input voltage))

Field

Description

Value

Header DU0

Function number

0x5F

Header DU1

Slot number (0)

0x00

Header DU2

Index (47)

0x2F

Header DU3

Length

0x0A

Request Header (Byte 1)

Request Reference

0x01

Request Header (Byte 2)

Request ID (0x01: Request) *

0x01

Request Header (Byte 3)

Axis

0x01

Request Header (Byte 4)

Number of Parameters

0x01

Parameter Address (Byte 1)

Attribute

0x10

Parameter Address (Byte 2)

Number of Elements

0x01

Parameter Address (Byte 3)

Parameter number, High byte **

0x03

Parameter Address (Byte 4)

Parameter number, Low byte **

0xE8

Parameter Address (Byte 5)

VF-MB1/S15 Parameter number, High byte

0xFD

Parameter Address (Byte 6)

VF-MB1/S15 Parameter number, Low byte

0x04

*Refer to Appendix.

**Parameter number is fixed to 0x03E8 (1000) for accessing to VF-MB1/S15 parameter.

6.3.2.Read Response data table (positive)

Field

Description

Value

Header DU0

Function number

0x5E

Header DU1

Slot number (0)

0x00

Header DU2

Index (47)

0x2F

Header DU3

Length

0x08

Request Header (Byte 1)

Request Reference (mirrored)

0x01

Request Header (Byte 2)

Response ID *

0x01

Request Header (Byte 3)

Axis (mirrored)

0x01

Request Header (Byte 4)

Number of Parameters

0x01

Parameter Value (Byte 1)

Format *

0x42

Parameter Value (Byte 2)

Number of Values

0x01

Parameter Value (Byte 3)

Values, High byte

0x31 **

Parameter Value (Byte 4)

Values, High byte

0xEC **

*Refer to Appendix.

**Value 0x31EC is "12780" in decimal. This means "127.80 (%)".

- 33 -

Image 35
Contents Tosvert VF-MB1/S15 Contents Introduction Safety precautions E6581738 E6581738 E6581738 Connection Information Exterior featuresDX Data exchange Green LED Status indicatorVF-MB1/S15 Communication parameters Telegram ProfileSTW Control Word Data PDP003Z supports only speed control mode Bit Value NameBit Valure Name ZSW Status Word DataZSW Bit Setpoint Actual value15s 20s 25s 30s TmaxState Machine Example 1 Hz Forward running and Deceleration stop AK Request from Master to PDP003Z) Access to the Profibus parameterProfibus parameter PNU Value Mode13 9A Example 1. Reading the PNU 922 TelegramAccess to VF-MB1/S15 parameter Response Value 0x03E8 = 1000 10.00Hz Vendor Spec. Profile Profibus Master How to useBit Function Overview of the VF-MB1/S15 parameter2. fa23 Communication command Specified data output ST=ON ST=OFF E6581738 RES RY-RC Diagnostic VF-MB1/S15 DP-V1 functionMaster Profibs DP-V1 CommunicationExample1. Read the PROFIdrive parameter 0x82 Example 2. Change the PROFIdrive parameter0x02 0x9F0x31 Example 3. Read the VF-MB1/S15 parameter0xE8 0xFD0x07 Example 4. Change the VF-MB1/S15 parameter0x30 GSD file Profibus Local/Remote OperationFunction number Appendix