4.2.6.fd01 (Inverter operating status 1 (real time))

bit

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Function

0

1

Note

Failure FL

No output

Under in

-

progress

 

 

Trip status includes rtry and

 

 

 

Failure

Not tripped

Tripped

the trip retention status are also

 

 

 

regarded as tripped statuses.

Alarm

No alarm

Alarm issued

-

Under voltage (moff)

Normal

Under voltage

-

Motor selection (1 or 2)

 

 

THR1: pt = setting value, vl,

Motor 1 (THR1)

Motor 2 (THR2)

vlv, vb, thr

(THR 2 selection)

 

 

THR2: pt = 0, f170, f171,

 

PID control

PID control

f172, f173

PID control off

-

permitted

prohibits

Acceleration/deceleratio

 

Acceleration/dec

Acceleration/dec

AD1: acc, dec

n pattern selection (1 or

eleration pattern

eleration pattern

2)

1 (AD1)

2 (AD2)

AD2: f500, f501

 

DC braking

OFF

Forced DC

-

braking

 

 

 

Jog run

OFF

Jog run

-

Forward / reverse run

Forward run

Reverse run

-

Run/stop

Stop

Run

-

Coast stop (ST = OFF)

ST=ON

ST=OFF

-

Emergency stop

No emergency

Emergency

-

stop status

stop status

 

Standby: Initialization

 

 

 

Standby ST=ON

Start-up process

Standby

completed, not failure stop

status, not alarm stop status

 

 

 

(moff, ll forced stop),

 

 

 

ST=ON, and RUN=ON

 

 

 

Standby: Initialization completed,

Standby

Start-up process

Standby

not failure stop status and not

alarm stop status (moff, ll

 

 

 

 

 

 

forced stop)

(Undefined)

-

-

-

Note: The bit described "Undefined" is unstable. Don't use the bit for the judgment.

4.2.7.fd00 (Output frequency (real time))

The current output frequency is read into 0.01Hz of units and by the hexadecimal number. For example, when the output frequency is 80Hz, 0x1F40 (hexadecimal number) are read.

Since the minimum unit is 0.01%,

0x1F40 (Hex.) = 8000(Dec.) * 0.01 = 80 (Hz)

 

Also about the following parameters, these are the same as this.

 

- fd22 (Feedback value of PID (real time))

Unit: 0.01Hz

- fd16 (Estimated speed (real time))

Unit: 0.01Hz

- fd29 (Input power (real time))

Unit: 0.01kW

- fd30 (Output power (real time))

Unit: 0.01kW

- 25 -

Image 27
Contents Tosvert VF-MB1/S15 Contents Introduction Safety precautions E6581738 E6581738 E6581738 Connection Information Exterior featuresDX Data exchange Green LED Status indicatorVF-MB1/S15 Communication parameters Telegram ProfileSTW Control Word Data PDP003Z supports only speed control mode Bit Value NameBit Valure Name ZSW Status Word DataZSW Bit Setpoint Actual value15s 20s 25s 30s TmaxState Machine Example 1 Hz Forward running and Deceleration stop AK Request from Master to PDP003Z) Access to the Profibus parameterProfibus parameter PNU Value Mode13 9A Example 1. Reading the PNU 922 TelegramAccess to VF-MB1/S15 parameter Response Value 0x03E8 = 1000 10.00Hz Vendor Spec. Profile Profibus Master How to useBit Function Overview of the VF-MB1/S15 parameter2. fa23 Communication command Specified data output ST=ON ST=OFF E6581738 RES RY-RC Diagnostic VF-MB1/S15 DP-V1 functionMaster Profibs DP-V1 CommunicationExample1. Read the PROFIdrive parameter 0x82 Example 2. Change the PROFIdrive parameter0x02 0x9F0x31 Example 3. Read the VF-MB1/S15 parameter0xE8 0xFDExample 4. Change the VF-MB1/S15 parameter 0x300x07 GSD file Profibus Local/Remote OperationFunction number Appendix