REAR PANEL
WARNING: The included power cord is used for 120 VAC, 60 Hz. Never connect the power cord to any output or power supply having a dif- ferent voltage or frequency.
Make sure the power cord is unplugged before making any rear panel terminal connections.
1 |
| 2 |
|
|
| 3 |
|
|
|
|
|
| BATTERY | OPEN |
|
ALM RST REC GND | MODE | CLK CALL |
|
|
|
| |
IN |
| OUT |
|
|
|
|
|
REMOTE MIC | IN | OUT | IN | OUT | RESET |
|
|
|
| AUDIO | VIDEO |
|
|
| |
5 |
| 7 | 8 | 9 | 10 | 11 |
|
4 | 6 |
| 00442 |
Figure 11. Rear Panel
1.AC power socket
The power cord plugs into this socket. Insert the cord firmly.
2.Terminals
•Input Terminals
ALM (alarm) IN
Use for alarm recording. Connect the alarm sensor here.
RST (reset) IN
Connect the alarm reset switch here to stop alarm recording when ALARM REC DURATION in the Recording Set Up menu is set to MAN1. You can also use this terminal to set the
REC (recording) IN
Use to start and stop recording or for series recording (refer to the Series Recording section).
•GND (ground)
Connect the ground lead here when a lead connected to other terminals requires a ground.
•Output Terminals
ALM (alarm) OUT
Use to indicate to an external device that an alarm is being recorded.
MODE OUT
Use to indicate the VCR’s mode of operation. When MODE OUT in the Rear Terminal menu is set to CLOCK ADJ, the clocks of all connected VCRs can be adjusted.
CLK (clock) OUT
Use to control an external camera switcher, such as the MX4000 Series Genex Multiplexer.
CALL OUT
Use to indicate when the tape finishes recording or that there was a problem during recording.
3.Battery box
The battery is stored here. (NOTE: This is a special battery. Consult your dealer to replace it.)
4.REMOTE jack
Jack for connecting a remote control unit.