Pelco TLR3168 operation manual Before Calling for Service, Symptom Remedy

Page 70

BEFORE CALLING FOR SERVICE

If you cannot solve your problem after checking the following list, stop using the VCR, unplug it from the outlet, and contact your dealer.

SYMPTOM

 

REMEDY

 

 

 

 

 

INSTALLATION PROBLEMS

 

 

 

 

No power at the VCR.

 

Is the power cord disconnected at the AC outlet?

 

 

Is the lock or lock all indicator lit? Refer to the

 

 

 

separate Caution sheet. See your supervisor if the

 

 

 

sheet is not attached to this manual.

 

 

Is the timer recording indicator lit? Press the TIMER

 

 

 

REC button on the front panel to cancel timer recording.

 

 

 

 

The VCR power is on

 

Is the lock or lock all indicator lit? Refer to the

but the unit does not

 

 

separate Caution sheet. See your supervisor if the

operate.

 

 

sheet is not attached to this manual.

 

 

Safety devices are operating. Press the RESET button

 

 

 

on the rear panel using a ballpoint pen or pencil. Turn

 

 

 

power on again.

 

 

 

 

No picture on the

 

Are the monitor and camera connected properly.

monitor.

 

 

Check the connection.

 

 

Is the video cable connected properly? Is the cable

 

 

 

defective? Check the connection and for a snapped

 

 

 

wire in the cable.

 

 

 

Picture on the monitor

 

Is the camera focused? Refer to your camera’s user

is not clear.

 

manual and focus the camera properly.

 

 

 

 

FUNCTION/OPERATION PROBLEMS

 

 

 

 

No operation when

 

Is the lock or lock all indicator lit? Refer to the

any tape operation

 

 

separate Caution sheet. See your supervisor if the

button is pressed.

 

 

sheet is not attached to this manual.

 

 

Is a cassette inserted?

 

 

 

The time is wrong

 

Make sure the VCR has AC power supplied continuously

even though the VCR

 

for at least 40 hours per week.

is used every day.

 

 

 

 

 

 

 

The power cord was

 

Make sure the VCR has AC power supplied

disconnected for less

 

 

continuously for at least 40 hours per week.

than 31 days but the

 

 

 

time has been reset.

 

Contents stored in memory may be erased before

 

 

 

the 31 days depending on the charge time of the

 

 

 

power failure compensation circuit. Set the time again.

 

 

 

A tape cannot be

 

Is the lock all indicator lit? Refer to the separate Caution

loaded.

 

sheet. See your supervisor if the sheet is not attached to

 

 

this manual.

 

 

 

 

70

Pelco Manual C673M (2/01)

Image 70
Contents TLR3168 Time-Lapse VCR Installation C673M 2/01 Contents Pelco Manual C673M 2/01 List of Illustrations List of TablesGeneral AvertissementSAFEGUARDS, WARNINGS, CAUTIONS, and Care Lightning/Power Surges CleaningAccessories When Not In UseUnpacking Instructions Introduction to TIME-LAPSE RecordersTLR3168 Features and Functions Basic Start Quick StartAdditional Items Securing the VCR Controls InstallationPRE-INSTALLATION Cautions Monitor TipsInstallation Typical System SetupConnecting the VCR to a Multiplexer Connecting a VCR to a MultiplexerConnecting for Series Recording Alarm Recording ConnectionConnecting for Remote Recording Connecting for Synchronous Recording Connecting for External Time Clock AdjustmentConnecting to a PC for Remote Control Connecting the VCR to a PCTable A. RS-232C Protocol Cable Connections Front Panel ControlsPLAY/REC Check Eject button POSITION/VERTICAL Adjust buttons +Timer REC button Search buttonFluorescent Display Emgcy emergency recording indicator Timer Recording indicatorTape Remaining indicator LOCK/LOCK a indicatorRear Panel Mode OUTCall OUT Using the Shuttle Ring Adjusting the Clock and Using the JOG and Shuttle ControlsUsing the JOG Dial JOG and Shuttle ControlsAdjusting the Clock Adjusting to the Exact SecondLanguage Selection Menu ProgrammingGeneral Programming Instructions MenuProgram to Record Holiday SET UP Quick Guide to the Menu StructureTIME/DATE Size Display Menu Display ModeMain Menu Blue BackTimer Program START/ENDRecording SET UP Menu Wrngtape END Wrngremain Tape END SettingRear Terminal Menu Clock OUTREC Maintenance Menu First Time SET UP MenuRS-232C Menu Additional Material DAY and Time Display ModesSET the DAY and Time Main Menu DisplayLOADING, UNLOADING, Protecting the Tape Cassette LoadingUnloading When to Replace a TapeTable C. Tape Replacement by Use Preventing Accidental ErasureRecording Manual RecordingAudio RECORDING/PLAYBACK Recording ModeRecording Check Function Repeat RecordingStop Rewind Repeat Alarmprot Table E. Action When Tape End Is Reached by SettingSeries Recording Remote Recording ONE-SHOT/INTERVAL RecordingSynchronous Recording Synchronous Recording SequenceTimer Recording Programming ProcedureWhat if the Timer Recording Indicator Starts FLASHING? Holiday SET UPSpecial DW Setting Overlapping ProgramsAlarm Recording Table G. Minimum Interval Between RecordingsProgramming for Alarm Recording Power Loss List MaintenanceRecording After a Power Failure Viewing the Power Loss ListClearing the Alarm List Alarm ListViewing the Alarm List ALL Menu Initialize ResetElapsed Time Elapsed Time and Repeat Recording Times DisplayRepeat REC Times Playback Procedure PlaybackEND of Tape Playback ModeAudio Playback Special Effects PlaybackShuttle Ring Direct Shuttle RingAdjusting the Picture During Playback Tracking Adjustment Adjusting Picture QualityVertical Vibration Adjustment Counter Memory Stop Search TechniquesSkip Search HOW to Count the Index Number Index SearchTime and Date Search Additional Functions and Features Using with a PC Assigning the RS-S32C SettingsWhen Controlling only ONE VCR Commands from a PCSending Commands Status or Error Code from Meaning When Controlling Multiple Vcrs Commands When Controlling Multiple VCRsVCR01, RC CR Commands and Responses Chart Commands Functions Status After Normal Explanation of StatusOn next SKP Small =WRNG, 1=WRNGTAPE END =OFF, 1=ON Initial System Testing TestingError Codes Regular System TestingTable J. Warning Display and Actions TroubleshootingSELF-DIAGNOSTIC Function and Warning Display Fluorescent Monitor Cause Remedy To Turn Off DisplayBefore Calling for Service Symptom RemedyRecording Problems Video and Audio SpecificationsElectrical MechanicalVideo Audio Tape Mode 120/T-160 Mm/s Field Fields/s Table K. Tape Speed and Recording TimeIndex Pelco Manual C673M 2/01 Regulatory Notices Revision History