TROUBLESHOOTING

SELF-DIAGNOSTIC FUNCTION AND WARNING DISPLAY

The VCR uses self-diagnostics to detect internal malfunctions during recording. If one occurs, the VCR indicates it on the fluorescent display and/or the monitor. Table J shows the type of malfunction corresponding to the warning display and the action to take.

Table J. Warning Display and Actions

Fluorescent

Monitor

Cause

Remedy

 

To Turn Off

Display

 

 

 

 

Indicator

 

 

 

 

 

 

End

TAPE END

Tape ends

Rewind tape or

 

Rewind tape or

 

 

during recording.

press EJECT.

 

press EJECT.

 

 

 

 

 

 

noSIg

NO SIGNAL

No video signal

Check for loose

 

Restore video

 

 

input during

connections.

 

signal or clear

 

 

recording.

 

 

recording mode.

 

 

 

 

 

(display

CHECK

Tape or deck

Check cassette. If nothing is wrong,

starts

 

trouble during

try recording again. If “CHECK” still

flashing)

 

recording.

appears, insert a new cassette and

 

 

 

retry recording. If “CHECK” stays on,

 

 

 

unplug the power cord and contact

 

 

 

the dealer.

 

 

 

 

 

 

 

CLog

---

Clogged head

Eject and

 

Clear the

 

 

during recording

reinsert the

 

recording mode.

 

 

at 120H-224H

cassette. Wait

 

 

 

 

or 0H (except

more than 5

 

 

 

 

for 128H) mode.

seconds. Repeat

 

 

 

 

 

4 or 5 times. Try

 

 

 

 

 

recording again.

 

 

 

 

 

If “CLog” remains,

 

 

 

 

 

consult your

 

 

 

 

 

dealer.

 

 

 

 

 

 

 

 

When the tape ends:

When the tape reaches its end during recording, “End” appears on the fluorescent display and “TAPE END” appears on the monitor. They will not appear if TAPE END in the First Time Set Up menu is set to REPEAT, ALARM•PROT (when no alarm recording is made), or REWIND.

Lack of video signal:

“NO SIGNAL” appears on the monitor and “noSIg” flashes on the fluorescent display when the VCR cannot get any video signal during recording. Check that the cable from the camera is not broken and the camera has power.

Clogged head:

When CLOG DETECT in the Recording Set Up menu is set to ON, the VCR automati- cally removes particles that have accumulated on the heads during recording at 120H- 224H or 0H modes (except for 128H mode). If they cannot be removed entirely, “CLog” flashes on the fluorescent display. If this happens, follow the remedy in Table J.

Pelco Manual C673M (2/01)

69

Image 69
Contents TLR3168 Time-Lapse VCR Installation C673M 2/01 Contents Pelco Manual C673M 2/01 List of Tables List of IllustrationsAvertissement GeneralSAFEGUARDS, WARNINGS, CAUTIONS, and Care Accessories CleaningLightning/Power Surges When Not In UseIntroduction to TIME-LAPSE Recorders Unpacking InstructionsTLR3168 Features and Functions Quick Start Basic StartAdditional Items PRE-INSTALLATION Cautions InstallationSecuring the VCR Controls Monitor TipsTypical System Setup InstallationConnecting a VCR to a Multiplexer Connecting the VCR to a MultiplexerAlarm Recording Connection Connecting for Series RecordingConnecting for Remote Recording Connecting for External Time Clock Adjustment Connecting for Synchronous RecordingConnecting the VCR to a PC Connecting to a PC for Remote ControlTable A. RS-232C Protocol Cable Connections Controls Front PanelPLAY/REC Check Timer REC button POSITION/VERTICAL Adjust buttons +Eject button Search buttonFluorescent Display Tape Remaining indicator Timer Recording indicatorEmgcy emergency recording indicator LOCK/LOCK a indicatorMode OUT Rear PanelCall OUT Using the JOG Dial Adjusting the Clock and Using the JOG and Shuttle ControlsUsing the Shuttle Ring JOG and Shuttle ControlsAdjusting to the Exact Second Adjusting the ClockGeneral Programming Instructions ProgrammingLanguage Selection Menu MenuQuick Guide to the Menu Structure Program to Record Holiday SET UPMain Menu Display Menu Display ModeTIME/DATE Size Blue BackSTART/END Timer ProgramRecording SET UP Menu Rear Terminal Menu SettingWrngtape END Wrngremain Tape END Clock OUTREC First Time SET UP Menu Maintenance MenuAdditional Material DAY and Time Display Modes RS-232C MenuMain Menu Display SET the DAY and TimeLoading LOADING, UNLOADING, Protecting the Tape CassetteTable C. Tape Replacement by Use When to Replace a TapeUnloading Preventing Accidental ErasureManual Recording RecordingRecording Check Function Recording ModeAudio RECORDING/PLAYBACK Repeat RecordingTable E. Action When Tape End Is Reached by Setting Stop Rewind Repeat AlarmprotSeries Recording ONE-SHOT/INTERVAL Recording Remote RecordingSynchronous Recording Sequence Synchronous RecordingProgramming Procedure Timer RecordingSpecial DW Setting Holiday SET UPWhat if the Timer Recording Indicator Starts FLASHING? Overlapping ProgramsTable G. Minimum Interval Between Recordings Alarm RecordingProgramming for Alarm Recording Recording After a Power Failure MaintenancePower Loss List Viewing the Power Loss ListViewing the Alarm List Alarm ListClearing the Alarm List ALL Menu Initialize ResetElapsed Time and Repeat Recording Times Display Elapsed TimeRepeat REC Times Playback Playback ProcedureAudio Playback Playback ModeEND of Tape Special Effects PlaybackDirect Shuttle Ring Shuttle RingAdjusting Picture Quality Adjusting the Picture During Playback Tracking AdjustmentVertical Vibration Adjustment Search Techniques Counter Memory StopSkip Search Index Search HOW to Count the Index NumberTime and Date Search Additional Functions and Features Assigning the RS-S32C Settings Using with a PCCommands from a PC When Controlling only ONE VCRSending Commands Status or Error Code from Meaning Commands When Controlling Multiple VCRs When Controlling Multiple VcrsVCR01, RC CR Commands Functions Status After Normal Explanation of Status Commands and Responses ChartOn next SKP Small =WRNG, 1=WRNGTAPE END =OFF, 1=ON Error Codes TestingInitial System Testing Regular System TestingSELF-DIAGNOSTIC Function and Warning Display TroubleshootingTable J. Warning Display and Actions Fluorescent Monitor Cause Remedy To Turn Off DisplaySymptom Remedy Before Calling for ServiceRecording Problems Electrical SpecificationsVideo and Audio MechanicalTable K. Tape Speed and Recording Time Video Audio Tape Mode 120/T-160 Mm/s Field Fields/sIndex Pelco Manual C673M 2/01 Revision History Regulatory Notices