Page 30

REAR TERMINAL MENU

<REAR TERMINAL>

CALL OUT

WRNG•TAPE END

CLOCK OUT

REC-1

MODE OUT

REC

REC IN

SERIES

00450

Figure 19. Rear Terminal Menu

Table B. Call Out/Tape End

CALL OUT

 

 

 

setting

WRNG•TAPE END

WRNG•REMAIN

WRNG

TAPE END

 

 

 

setting

 

 

 

STOP

Outputs a call

Outputs a low

When a

 

signal at the end of

active signal

malfunction

 

the tape.

three minutes

occurs in the

 

 

before the tape

VCR during

 

 

ends.

recording, a call

 

 

 

signal is output.

REWIND

Outputs a call

Same as above

Same as above

 

signal at the end of

 

 

 

the tape for two

 

 

 

seconds.

 

 

REPEAT

When there are alarm recordings during

ALARM recording

•PROT When there are no alarm recordings during recording

Same as above

Same as above

Same as above

Outputs a call

Same as above

Same as above

signal at the end of

 

 

the tape.

 

 

Outputs a call signal

Same as above

Same as above

at the end of the

 

 

tape for two

 

 

seconds. Tape

 

 

rewinds and

 

 

recording continues.

 

 

CALL OUT

Sets the call signal output at the end of the tape. Turns on or off the

 

signal coming from the CALL terminal when the end of the tape is

 

reached during recording. If a problem occurs during recording, a call

 

signal is output from the CALL terminal on the rear panel regardless of

 

the CALL OUT setting.

 

WRNG•TAPE END – The VCR outputs a call signal at the end of

 

 

the tape when recording or when a malfunction occurs when

 

 

recording. What the VCR does when the tape ends depends on

 

 

the setting for TAPE END in the First Time Set Up menu.

 

WRNG•REMAIN – The VCR outputs a call signal when the tape

 

 

has about nine minutes left (in 6H mode) during recording or

 

 

when a malfunction occurs during recording.

 

WRNG – The VCR outputs a call signal only when a malfunction

 

 

occurs during recording.

CLOCK OUT

Sets, at the CLOCK OUT terminal, the number of frames or fields

 

being recorded (depending on the recording mode).

 

1.

First, set the recording mode for the CLOCK OUT pulse output in

 

 

the Rear Terminal menu.

 

 

REC – When recording in any mode

 

 

T/L REC - When recording in time-lapse mode (L18H – 224H

 

 

 

or 0H)

 

2.

Second, select the frequency interval by turning the JOG dial,

 

 

switching the display in the following order: 1, 2, 3, 4, 5, 10, 15,

 

 

20, 25, 30, 50, 60, F (field), 1. The numbers from 1 to 60 indicate

 

 

the number of frames at 6H recording mode and the number of

 

 

fields at time-lapse recording modes. (One frame consists of two

 

 

fields.) One field is selected when set to F (field).

30

Pelco Manual C673M (2/01)

Image 30
Contents TLR3168 Time-Lapse VCR Installation C673M 2/01 Contents Pelco Manual C673M 2/01 List of Illustrations List of TablesGeneral AvertissementSAFEGUARDS, WARNINGS, CAUTIONS, and Care Lightning/Power Surges CleaningAccessories When Not In UseUnpacking Instructions Introduction to TIME-LAPSE RecordersTLR3168 Features and Functions Quick Start Basic StartAdditional Items Securing the VCR Controls InstallationPRE-INSTALLATION Cautions Monitor TipsInstallation Typical System SetupConnecting the VCR to a Multiplexer Connecting a VCR to a MultiplexerAlarm Recording Connection Connecting for Series RecordingConnecting for Remote Recording Connecting for Synchronous Recording Connecting for External Time Clock AdjustmentConnecting the VCR to a PC Connecting to a PC for Remote ControlTable A. RS-232C Protocol Cable Connections Controls Front PanelPLAY/REC Check Eject button POSITION/VERTICAL Adjust buttons +Timer REC button Search buttonFluorescent Display Emgcy emergency recording indicator Timer Recording indicatorTape Remaining indicator LOCK/LOCK a indicatorMode OUT Rear PanelCall OUT Using the Shuttle Ring Adjusting the Clock and Using the JOG and Shuttle ControlsUsing the JOG Dial JOG and Shuttle ControlsAdjusting the Clock Adjusting to the Exact SecondLanguage Selection Menu ProgrammingGeneral Programming Instructions MenuProgram to Record Holiday SET UP Quick Guide to the Menu StructureTIME/DATE Size Display Menu Display ModeMain Menu Blue BackTimer Program START/ENDRecording SET UP Menu Wrngtape END Wrngremain Tape END SettingRear Terminal Menu Clock OUTREC Maintenance Menu First Time SET UP MenuRS-232C Menu Additional Material DAY and Time Display ModesSET the DAY and Time Main Menu DisplayLOADING, UNLOADING, Protecting the Tape Cassette LoadingUnloading When to Replace a TapeTable C. Tape Replacement by Use Preventing Accidental ErasureRecording Manual RecordingAudio RECORDING/PLAYBACK Recording ModeRecording Check Function Repeat RecordingTable E. Action When Tape End Is Reached by Setting Stop Rewind Repeat AlarmprotSeries Recording Remote Recording ONE-SHOT/INTERVAL RecordingSynchronous Recording Synchronous Recording SequenceTimer Recording Programming ProcedureWhat if the Timer Recording Indicator Starts FLASHING? Holiday SET UPSpecial DW Setting Overlapping ProgramsAlarm Recording Table G. Minimum Interval Between RecordingsProgramming for Alarm Recording Power Loss List MaintenanceRecording After a Power Failure Viewing the Power Loss ListClearing the Alarm List Alarm ListViewing the Alarm List ALL Menu Initialize ResetElapsed Time and Repeat Recording Times Display Elapsed TimeRepeat REC Times Playback Procedure PlaybackEND of Tape Playback ModeAudio Playback Special Effects PlaybackShuttle Ring Direct Shuttle RingAdjusting the Picture During Playback Tracking Adjustment Adjusting Picture QualityVertical Vibration Adjustment Search Techniques Counter Memory StopSkip Search HOW to Count the Index Number Index SearchTime and Date Search Additional Functions and Features Using with a PC Assigning the RS-S32C SettingsCommands from a PC When Controlling only ONE VCRSending Commands Status or Error Code from Meaning When Controlling Multiple Vcrs Commands When Controlling Multiple VCRsVCR01, RC CR Commands and Responses Chart Commands Functions Status After Normal Explanation of StatusOn next SKP Small =WRNG, 1=WRNGTAPE END =OFF, 1=ON Initial System Testing TestingError Codes Regular System TestingTable J. Warning Display and Actions TroubleshootingSELF-DIAGNOSTIC Function and Warning Display Fluorescent Monitor Cause Remedy To Turn Off DisplayBefore Calling for Service Symptom RemedyRecording Problems Video and Audio SpecificationsElectrical MechanicalVideo Audio Tape Mode 120/T-160 Mm/s Field Fields/s Table K. Tape Speed and Recording TimeIndex Pelco Manual C673M 2/01 Regulatory Notices Revision History