Pelco DX3016-060 manual AC power socket, RS-232C connector, Alarm in terminals, GND terminals

Page 12

6.AC power socket

This socket is for a 100-240 VAC power cord.

7.RS-232C connector

This is where a PelcoNet™ Transmission System can be connected for remote view- ing and control of cameras.

8.ALARM IN terminals

These are input terminals for alarm signals.

GND terminals

These are earth ground terminals for the ALARM IN terminals. Use only the terminal screws provided with this unit; otherwise, the recorder could be damaged or connec- tions may be poor.

9.I/O terminals

GND terminals

These are ground terminals for the input/output terminals.

CLOCK ADJ terminal

This is an input terminal to set the time display. The time display is adjusted to the nearest hour (00 minutes, 00 seconds) when this terminal receives the clock adjust signal.

REC terminal

This is an input terminal to start recording.

POWER ON terminal

This is an input terminal to turn on the recorder through a peripheral device.

POWER OFF terminal

This is an input terminal to turn off the recorder through a peripheral device.

ALARM OUT terminal

This is an output terminal to indicate that an alarm recording is being made.

MODE OUT terminal

This is an output terminal to indicate the recorder’s current mode. Select the mode in the Rear Terminal menu.

CALL OUT terminal / CALL OUT GND terminal

This is an isolated (optically coupled) output to indicate information such as the hard disk drive is full. Refer to the Warnings section.

DC 5V OUT terminal

This terminal is for direct current voltage output. The maximum current is 30 mA.

10.SCSI connector

This connector is for peripheral recording devices.

11.RESET button

When pressed, the present time is erased, the system is reset, and the power is turned off.

SCSI TERMINATION switch

When set to ON, the termination function is enabled; when set to OFF, the termination function is disabled. Set the switch ON when nothing is connected to the SCSI connector.

12.Ethernet connector (DX3016 Models Only)

Not used.

Pelco Manual C681M-D (2/02)

11

Image 12
Contents Entering Initial Password Changing PasswordPassword Error Turning Password Lock On and OffUL Listed Contents Using the Copy Button Changing Playback Interval Fast FORWARD/REWIND SearchingList of Illustrations Important Safeguards and Warnings Overview DescriptionGB PER Unit Power button Timer REC buttonModels Front Panel Controls Recording indicators Timer REC indicator DET indicator PRE Alarm REC indicator Multiplexer buttons Camera number buttonsMode indicators Access indicator Lock indicatorSET UP button Copy indicatorRear Panel Connectors AC power socket RS-232C connectorAlarm in terminals Power on terminalInstallation Camera #1Schematics for Alarm Input and Output Terminals Schematics for Input and Output Terminals DVD-RAM HDDIomega Z250S Adding or Removing a Copy or Archive Device Adding a Hard DrivesBOOT-UP Delay Removing a Hard DrivesConfirming That a Device is Connected SET UP ProgrammingMenu Tree, DX3009 Models Pelco Manual C681M-D 2/02 Menu Tree, DX3016 Models Menu Tree, DX3016 Models Pelco Manual C681M-D 2/02 Alarms Image Quality Maximum Recording FieldsBASIC, STANDARD, MEDIUM, HIGH, Superior Define Group Setting Alarm Recording Duration Record AlarmPRE-ALARM Recording ALL, SEPOFF, SHORT, MEDIUM, Long DET Setting Archive Pointer ResetArchive Data Overwrite Audio Recording Auto EjectBuzzer KEY, WRNG, REMAIN, OFFCall OUT Capacity RemainingData Clear Erase Selection HDD, ARC, NoneFIFO/OVERWRITE Mode DX3016 Models Only Backup Following a Power FailureHard Disk Drive HDD Full IM-CHECK Mode Hard Disk Drive HDD Repeat PlaybackMode OUT Initialize MenusREC, PLAY, POWER, Remain Motion DetectionLOW, LOWER, HIGHER, HIGH, MED Multiplexer Display Four-Camera Split 4 Setting Screen Switch Pattern DX3016 Models OnlySplit 4 Screen Setting DX3016 Models Only Split 9 Screen Setting DX3016 Models OnlySplit 16 Screen Setting DX3016 Models Only Sequence Channel Title Displaying Camera Title and/or NumberAlarm Display NONE, TITLE, CH. noPower Failure Camera TitleRecord Image Quality Maximum Recording Fields Select Recording Mode Define GroupRS-232C Communication Saving Menu Settings Saving Menu DataRestoring Menu Data TCP/IP Setting DX3016 Models Only Time and Date Display Display ModeCharacter Size Time and Date Setting Clock LocationTitle Timer Recording C, SKIP, ARC, Power Repeat steps 8-10 for the ending timeSetting for the prioritized Program #2 Motion Detection During a Timer Recording DX3016 Models Only Estimating Recording Time Operation SATViewing Cameras SPLIT/SEQUENCE ButtonDX3009 Models DX3009 Models Nine camerasZoom Buttons Remote ViewingRecording Basic Recording Alarm Recording Timer Recording in the Programming section Playback Basic PlaybackAdjusting Playback Speed Regular Playback ModeFRAME-BY-FRAME Still Frame Playback Pause PlaybackChanging Playback Interval Fast FORWARD/REWINDSearching Index Search Skip Search Alarm List Search Jump to Starting PointUsing the Archive Button Playback on Another DeviceBacking UP Data Auto-Eject at the Completion of Backup Using the Copy ButtonStill-Frame Playback Copy Mode Simultaneous Recording and BackupDX3016 Models Restoring Data from a Backup Device Power Failure List Information Elapsed Time DisplayReset Recorded PeriodScsi Devices Connected DX3009 Recording Time Tables Audio recording time tableWithout Audio recording Audio recordingDX3009 Recording Time Tables Audio recording, Pre-Alarm Recording duration is set to Long DX3016 Recording Time Tables BasicWithout Audio recording, recording duration is set to Short Audio recording, recording duration is set to LongAudio recording, recording duration is set to Medium Audio recording, recording duration is set to ShortCall OUT Troubleshooting Description of problem Please consult the followingIs the Lock function or the Password Lock function Specifications JpegPCM Power on Power OFFAlarm OUT Power ON, Power OFF, Alarm IN, Clock ADJ, RECWarranty and Return Information Regulatory Notices