Pelco DX3009-060, DX3016-060, DX3016-120 manual Menu Tree, DX3009 Models Pelco Manual C681M-D 2/02

Page 20

SET UP

MAIN MENU

<MENU SETTING> TIME DATE DISPLAY MPX DISPLAY TIMER PROGRAM NORMAL REC SETTING

A-REC/M-DET SETTING DATA CLEAR SELECTION COMMUNICATION SETTING REAR TERMINAL SERVICE

INITIAL SET UP

SUB MENU (1)

<A-REC/M-DET SETTING>

 

 

 

IMAGE QUALITY

HIGH

 

 

MAX REC FIELDS

15F

 

 

DEFINE GROUP SETTING

 

 

 

A-REC DURATIOM

1M

 

 

RECORD ALARM

SEP

 

 

PRE A-REC

OFF

 

 

M-DET SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<DATA CLEAR SELECTION>

 

 

 

#1

COPY DATA CLEAR

OFF

 

 

 

 

ARCHIVE DATA CLEAR

OFF

 

 

#2

 

 

HDD DATA CLEAR

OFF

 

 

 

 

 

 

 

SUB MENU (2)

<DEFINE ALARM GROUP>

CH

PRI FILD

CH

PRI FILD

1

1

6

1

2

1

7

1

3

1

8

1

4

1

9

1

51

<MOTION>

 

 

 

 

SELECTION CAMERA NO.

1

 

 

 

CH.MOTION DETECTION

OFF

 

 

SET DETECTION MASK

 

 

 

 

 

SENSITIVITY

MED

 

 

MOTION THRESHOLD

2

 

 

 

TEST MODE

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUB MENU (3)

: MOVE

< < : EXIT

 

 

< < : EXIT

<COMMUNICATION SETTING>

 

 

 

<RS-232C SETTING>

 

RS-232C SETTING

 

 

 

 

TRANSMISSION RATE

1200

 

 

 

 

 

DATA BIT LENGTH

8BIT

 

 

 

 

 

PARITY BIT

NONE

 

 

 

 

 

STOP BIT LENGTH

1BIT

 

 

 

 

 

DELIMITER

CR

 

 

 

 

 

 

 

 

 

 

 

<REAR TERMINAL>

 

 

 

<CALL OUT>

 

 

 

 

MODE OUT

REC

 

 

HDD(ID:0-3)

FULL

 

 

CAPACITY REMAIN

HDD-10%

 

 

ARCHIVE(ID:4)

NONE

 

 

#2

 

 

 

 

CALL OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BUZZER

KEY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<SERVICE>

 

 

 

<POWER FAILURE>

 

 

POWER FAILURE

 

 

 

 

No.

DATE

TIME

INFO.

ARCHIVE POINT RESET

OFF

 

 

01

01-23-00

20:00

PW-LOS

MENU INITIALIZE

OFF

 

 

02

01-24-00

12:00

PW-LOS

IM-CHECK MODE

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<INITIAL SET UP>

 

 

 

 

 

<TIME DATE ADJUST>

 

TIME DATE ADJUST

 

 

 

 

 

 

DAYLIGHT SAVING

OUT

HDD FULL

STOP

 

 

 

MONTH

01

HDD PB REPEAT

STOP

 

#2

 

DATE

01

ARCHIVE OVERWRITE

OFF

 

 

 

YEAR

2000

 

 

 

AUTO EJECT

ON

 

 

#2

 

TIME

00:00:00

 

 

 

ARCHIVE DATA

ALL

 

 

#2

 

 

 

 

 

 

 

 

MOTION DETECTION

OFF

 

 

 

TURN THE SHUTTLE RING

 

AUDIO RECORDING

OFF

 

 

 

<< TO EXECUTE.

 

 

 

 

 

 

 

 

 

 

#1 - This is displayed only when a copying device is connected to ID5.

 

#2 - This is displayed only when an ARCHIVE device is connected to ID4.

01134

Figure 13. Menu Tree, DX3009 Models (Continued)

Pelco Manual C681M-D (2/02)

19

Image 20
Contents Entering Initial Password Changing PasswordPassword Error Turning Password Lock On and OffUL Listed Contents Using the Copy Button Changing Playback Interval Fast FORWARD/REWIND SearchingList of Illustrations Important Safeguards and Warnings GB PER Unit OverviewDescription Power button Timer REC buttonModels Front Panel ControlsRecording indicators Timer REC indicator DET indicatorPRE Alarm REC indicator Multiplexer buttons Camera number buttonsMode indicators Access indicator Lock indicatorSET UP button Copy indicatorRear Panel Connectors AC power socket RS-232C connectorAlarm in terminals Power on terminalInstallation Camera #1Schematics for Alarm Input and Output Terminals Schematics for Input and Output Terminals Iomega Z250S DVD-RAMHDD Adding or Removing a Copy or Archive Device Adding a Hard DrivesConfirming That a Device is Connected BOOT-UP DelayRemoving a Hard Drives SET UP ProgrammingMenu Tree, DX3009 Models Pelco Manual C681M-D 2/02 Menu Tree, DX3016 Models Menu Tree, DX3016 Models Pelco Manual C681M-D 2/02 BASIC, STANDARD, MEDIUM, HIGH, Superior Alarms Image QualityMaximum Recording Fields Define Group Setting Alarm Recording Duration Record AlarmOFF, SHORT, MEDIUM, Long PRE-ALARM RecordingALL, SEP Archive Data DET SettingArchive Pointer Reset Overwrite Audio Recording Auto EjectBuzzer KEY, WRNG, REMAIN, OFFCall OUT Capacity RemainingData Clear Erase Selection HDD, ARC, NoneFIFO/OVERWRITE Mode DX3016 Models Only Backup Following a Power FailureHard Disk Drive HDD Full IM-CHECK Mode Hard Disk Drive HDD Repeat PlaybackMode OUT Initialize MenusREC, PLAY, POWER, Remain Motion DetectionLOW, LOWER, HIGHER, HIGH, MED Multiplexer Display Four-Camera Split 4 Setting Screen Switch Pattern DX3016 Models OnlySplit 4 Screen Setting DX3016 Models Only Split 9 Screen Setting DX3016 Models OnlySplit 16 Screen Setting DX3016 Models Only Sequence Channel Title Displaying Camera Title and/or NumberAlarm Display NONE, TITLE, CH. noRecord Image Quality Power FailureCamera Title Maximum Recording Fields Select Recording Mode Define GroupRS-232C Communication Restoring Menu Data Saving Menu SettingsSaving Menu Data TCP/IP Setting DX3016 Models Only Time and Date Display Display ModeCharacter Size Title Time and Date SettingClock Location Timer Recording C, SKIP, ARC, Power Repeat steps 8-10 for the ending timeSetting for the prioritized Program #2 Motion Detection During a Timer Recording DX3016 Models Only Estimating Recording Time Operation SATViewing Cameras SPLIT/SEQUENCE ButtonDX3009 Models DX3009 Models Nine camerasRecording Basic Recording Zoom ButtonsRemote Viewing Alarm Recording Timer Recording in the Programming section Playback Basic PlaybackAdjusting Playback Speed Regular Playback ModeFRAME-BY-FRAME Still Frame Playback Pause PlaybackSearching Changing Playback IntervalFast FORWARD/REWIND Index Search Skip Search Alarm List Search Jump to Starting PointBacking UP Data Using the Archive ButtonPlayback on Another Device Auto-Eject at the Completion of Backup Using the Copy ButtonDX3016 Models Still-Frame Playback Copy ModeSimultaneous Recording and Backup Restoring Data from a Backup Device Power Failure List Information Elapsed Time DisplayScsi Devices Connected ResetRecorded Period DX3009 Recording Time Tables Audio recording time tableWithout Audio recording Audio recordingDX3009 Recording Time Tables Audio recording, Pre-Alarm Recording duration is set to Long DX3016 Recording Time Tables BasicWithout Audio recording, recording duration is set to Short Audio recording, recording duration is set to LongAudio recording, recording duration is set to Medium Audio recording, recording duration is set to ShortCall OUT Troubleshooting Description of problem Please consult the followingIs the Lock function or the Password Lock function PCM SpecificationsJpeg Power on Power OFFAlarm OUT Power ON, Power OFF, Alarm IN, Clock ADJ, RECWarranty and Return Information Regulatory Notices