The REC input terminal is used to start recording. Refer to Series Recording in this step for more information. The input is active when a ground or low voltage signal is applied. The in- put is non-active when the terminal is open.

The MODE OUT output terminal is used to indicate the status of the recorder (refer to Mode Out in the Programming section for more information). It can also be used to turn on an- other recorder (refer to Series Recording in this step for more information). The output is active when the terminal is at a low voltage level and non-active when the terminal is open. Maximum current drive is 7 mA DC, and the maximum voltage is +24 VDC.

The CALL OUT output terminal is used for warnings (refer to the Warnings section for more information). It can also be used to turn on another recorder (refer to Series Recording in this step for more information). The output is active when the optical coupler is turned on and non-active when the optical coupler is turned off. Maximum current drive is 7 mA DC, and the maximum voltage is +24 VDC.

POWER ON/POWER OFF/￿ ALARM IN/REC/CLOCK ADJ￿

Input terminal ￿ 5V

• Input Circuit

10k￿ 5V

Input￿ 22k￿ terminal

0.047µF￿

￿

GND

<Interface circuit inside the unit>

ALARM OUT/MODE OUT Output terminal ￿

CALL OUT output terminal ￿

• Output Circuit

• Output Circuit

Output terminal

CALL OUT terminal

 

GND terminal

CALL OUT GND terminal

 

<Interface circuit inside the unit>

 

 

<Interface circuit inside the unit>

Figure 10. Schematics for Input and Output Terminals

SERIES RECORDING

By connecting multiple units in series as shown in Figure 11, when the one unit’s hard disk is full, the next unit automatically begins recording.

In this example, when the first unit’s hard disk is full, the second unit begins recording; when the second unit’s hard disk is full, the first unit begins overwriting its hard disk. If you do not want the first unit to overwrite its hard disk, do not connect MODE OUT from the second unit to REC of the first unit. The series recording function can also be activated by connecting the CALL OUT terminal in place of the MODE OUT terminal; the disk storage capacity setting is made in the Call Out menu. When the CALL OUT terminal is used, if the first unit reaches the preset capacity, experiences a malfunction, or otherwise cannot con- tinue recording, the second unit begins recording.

First Unit

REC POWER ON POWER OFF

ALARM-OUT MODE-OUT CALL OUT

CALL OUT GND GND

GND

MAX 30mA

DC 5V OUT

Second Unit

GNDCLOCKRECPOWERPOWERALARMMODECALLOUTCALL ADJUSTONOFFOUTOUTOUTGND

GND

GND

Figure 11. Connecting Recorders in Series

14

Pelco Manual C681M-D (2/02)

Image 15
Contents Turning Password Lock On and Off Entering Initial PasswordChanging Password Password ErrorUL Listed Contents Changing Playback Interval Fast FORWARD/REWIND Searching Using the Copy ButtonList of Illustrations Important Safeguards and Warnings Overview DescriptionGB PER Unit Front Panel Controls Power buttonTimer REC button ModelsMultiplexer buttons Camera number buttons Recording indicators Timer REC indicatorDET indicator PRE Alarm REC indicatorCopy indicator Mode indicators Access indicatorLock indicator SET UP buttonRear Panel Connectors Power on terminal AC power socket RS-232C connector Alarm in terminalsCamera #1 InstallationSchematics for Alarm Input and Output Terminals Schematics for Input and Output Terminals DVD-RAM HDDIomega Z250S Adding a Hard Drives Adding or Removing a Copy or Archive DeviceBOOT-UP Delay Removing a Hard DrivesConfirming That a Device is Connected Programming SET UPMenu Tree, DX3009 Models Pelco Manual C681M-D 2/02 Menu Tree, DX3016 Models Menu Tree, DX3016 Models Pelco Manual C681M-D 2/02 Alarms Image Quality Maximum Recording FieldsBASIC, STANDARD, MEDIUM, HIGH, Superior Define Group Setting Record Alarm Alarm Recording DurationPRE-ALARM Recording ALL, SEPOFF, SHORT, MEDIUM, Long DET Setting Archive Pointer ResetArchive Data Overwrite Auto Eject Audio RecordingKEY, WRNG, REMAIN, OFF BuzzerCapacity Remaining Call OUTHDD, ARC, None Data Clear Erase SelectionBackup Following a Power Failure FIFO/OVERWRITE Mode DX3016 Models OnlyHard Disk Drive HDD Full Hard Disk Drive HDD Repeat Playback IM-CHECK ModeInitialize Menus Mode OUTMotion Detection REC, PLAY, POWER, RemainLOW, LOWER, HIGHER, HIGH, MED Multiplexer Display Screen Switch Pattern DX3016 Models Only Four-Camera Split 4 SettingSplit 9 Screen Setting DX3016 Models Only Split 4 Screen Setting DX3016 Models OnlySplit 16 Screen Setting DX3016 Models Only Channel Title Displaying Camera Title and/or Number SequenceNONE, TITLE, CH. no Alarm DisplayPower Failure Camera TitleRecord Image Quality Maximum Recording Fields Define Group Select Recording ModeRS-232C Communication Saving Menu Settings Saving Menu DataRestoring Menu Data Time and Date Display Display Mode TCP/IP Setting DX3016 Models OnlyCharacter Size Time and Date Setting Clock LocationTitle Timer Recording Repeat steps 8-10 for the ending time C, SKIP, ARC, PowerSetting for the prioritized Program #2 Motion Detection During a Timer Recording DX3016 Models Only Estimating Recording Time SAT OperationDX3009 Models Nine cameras Viewing CamerasSPLIT/SEQUENCE Button DX3009 ModelsZoom Buttons Remote ViewingRecording Basic Recording Alarm Recording Playback Basic Playback Timer Recording in the Programming sectionPause Playback Adjusting Playback SpeedRegular Playback Mode FRAME-BY-FRAME Still Frame PlaybackChanging Playback Interval Fast FORWARD/REWINDSearching Index Search Skip Search Jump to Starting Point Alarm List SearchUsing the Archive Button Playback on Another DeviceBacking UP Data Using the Copy Button Auto-Eject at the Completion of BackupStill-Frame Playback Copy Mode Simultaneous Recording and BackupDX3016 Models Restoring Data from a Backup Device Information Elapsed Time Display Power Failure ListReset Recorded PeriodScsi Devices Connected Audio recording DX3009 Recording Time TablesAudio recording time table Without Audio recordingDX3009 Recording Time Tables Audio recording, Pre-Alarm Recording duration is set to Long Basic DX3016 Recording Time TablesAudio recording, recording duration is set to Long Without Audio recording, recording duration is set to ShortAudio recording, recording duration is set to Short Audio recording, recording duration is set to MediumCall OUT Description of problem Please consult the following TroubleshootingIs the Lock function or the Password Lock function Specifications JpegPCM Power ON, Power OFF, Alarm IN, Clock ADJ, REC Power onPower OFF Alarm OUTRegulatory Notices Warranty and Return Information