Pelco DX3016-060, DX3016-120, DX3009-060 Zoom Buttons, Remote Viewing, Recording Basic Recording

Page 60

ZOOM BUTTONS

NOTE: You cannot operate the ZOOM buttons when a menu is displayed on the screen. The buttons do not work when the recorder is accessing a peripheral recording device or the ARCHIVE, COPY, or PLAY button is flashing.

1.Display the Zoom Pointer (X) by pressing the ZOOM button.

2.Move the pointer to the desired position by pressing the camera number buttons 6 to 9. The picture will be enlarged/reduced from the center of the pointer.

3.Press the 4 button once to make the picture twice as large as the original picture size. Press the button a second time to make the picture four times as large. The zoom ratio appears in the top left-hand corner of the screen. As the zoom function is digital, details of the image appear pixelized when enlarged. After enlarging the picture, you can move the whole picture by pressing the 6-9 buttons.

4.After enlarging the picture, press the 5 button to reduce it.

The zoom pointer’s position does not change when the display screen changes or when power is turned off. This is convenient for situations where the desired viewing areas, such as a counter or cash register, are determined in advance. In addition, the zoom pointer can be used during playback of recorded images.

When playing back images from multiple cameras on a single screen, if the zoom control is used during the pause mode, there is a possibility that a black screen will be displayed. In this case, the desired enlarged image can be obtained by moving through frames using the JOG dial.

The zoom function is deactivated if the ALARM IN terminal is triggered.

REMOTE VIEWING

Camera images can be viewed from a remote site using a PelcoNet Transmission System.

To view images remotely, refer to separate documentation that accompanies PelcoNet.

RECORDING

BASIC RECORDING

1.Press a camera number button and verify that there is video.

2.Press the REC button. The REC button lights and recording starts.

If you press the PAUSE button during recording, recording will pause. To resume re- cording, press the PAUSE button again. (The PAUSE button only works when MAIN is selected as a playback device. Press the PLAY DEVICE button to select MAIN.)

A warning appears during recording if there is no input signal from the selected cam- era channel (refer to the Warnings section.) In addition, select “ - ” in the Define Group menu for those cameras with no input (refer to Record, Define Group in the Program- ming section). If the unit is operated without this “ - ” setting, there may be occasions during split-screen viewing when an image from another screen will appear in a chan- nel without an input signal.

The HDD FULL setting determines the operation of the recorder when the hard disk is full. Refer to HDD (Hard Disk Drive) Repeat Recording in the Programming section.

If multiple recorders are connected in series, when the storage capacity of the one unit’s memory reaches a pre-specified level, the next unit begins recording. Through this exchange, recording continues uninterrupted.

3.Press the STOP button to stop recording. The REC button light goes out.

Pelco Manual C681M-D (2/02)

59

Image 60
Contents Entering Initial Password Changing PasswordPassword Error Turning Password Lock On and OffUL Listed Contents Using the Copy Button Changing Playback Interval Fast FORWARD/REWIND SearchingList of Illustrations Important Safeguards and Warnings Overview DescriptionGB PER Unit Power button Timer REC buttonModels Front Panel ControlsRecording indicators Timer REC indicator DET indicatorPRE Alarm REC indicator Multiplexer buttons Camera number buttonsMode indicators Access indicator Lock indicatorSET UP button Copy indicatorRear Panel Connectors AC power socket RS-232C connectorAlarm in terminals Power on terminalInstallation Camera #1Schematics for Alarm Input and Output Terminals Schematics for Input and Output Terminals DVD-RAM HDDIomega Z250S Adding or Removing a Copy or Archive Device Adding a Hard DrivesBOOT-UP Delay Removing a Hard DrivesConfirming That a Device is Connected SET UP ProgrammingMenu Tree, DX3009 Models Pelco Manual C681M-D 2/02 Menu Tree, DX3016 Models Menu Tree, DX3016 Models Pelco Manual C681M-D 2/02 Alarms Image Quality Maximum Recording FieldsBASIC, STANDARD, MEDIUM, HIGH, Superior Define Group Setting Alarm Recording Duration Record AlarmPRE-ALARM Recording ALL, SEPOFF, SHORT, MEDIUM, Long DET Setting Archive Pointer ResetArchive Data Overwrite Audio Recording Auto EjectBuzzer KEY, WRNG, REMAIN, OFFCall OUT Capacity RemainingData Clear Erase Selection HDD, ARC, NoneFIFO/OVERWRITE Mode DX3016 Models Only Backup Following a Power FailureHard Disk Drive HDD Full IM-CHECK Mode Hard Disk Drive HDD Repeat PlaybackMode OUT Initialize MenusREC, PLAY, POWER, Remain Motion DetectionLOW, LOWER, HIGHER, HIGH, MED Multiplexer Display Four-Camera Split 4 Setting Screen Switch Pattern DX3016 Models OnlySplit 4 Screen Setting DX3016 Models Only Split 9 Screen Setting DX3016 Models OnlySplit 16 Screen Setting DX3016 Models Only Sequence Channel Title Displaying Camera Title and/or NumberAlarm Display NONE, TITLE, CH. noPower Failure Camera TitleRecord Image Quality Maximum Recording Fields Select Recording Mode Define GroupRS-232C Communication Saving Menu Settings Saving Menu DataRestoring Menu Data TCP/IP Setting DX3016 Models Only Time and Date Display Display ModeCharacter Size Time and Date Setting Clock LocationTitle Timer Recording C, SKIP, ARC, Power Repeat steps 8-10 for the ending timeSetting for the prioritized Program #2 Motion Detection During a Timer Recording DX3016 Models Only Estimating Recording Time Operation SATViewing Cameras SPLIT/SEQUENCE ButtonDX3009 Models DX3009 Models Nine camerasZoom Buttons Remote ViewingRecording Basic Recording Alarm Recording Timer Recording in the Programming section Playback Basic PlaybackAdjusting Playback Speed Regular Playback ModeFRAME-BY-FRAME Still Frame Playback Pause PlaybackChanging Playback Interval Fast FORWARD/REWINDSearching Index Search Skip Search Alarm List Search Jump to Starting PointUsing the Archive Button Playback on Another DeviceBacking UP Data Auto-Eject at the Completion of Backup Using the Copy ButtonStill-Frame Playback Copy Mode Simultaneous Recording and BackupDX3016 Models Restoring Data from a Backup Device Power Failure List Information Elapsed Time DisplayReset Recorded PeriodScsi Devices Connected DX3009 Recording Time Tables Audio recording time tableWithout Audio recording Audio recordingDX3009 Recording Time Tables Audio recording, Pre-Alarm Recording duration is set to Long DX3016 Recording Time Tables BasicWithout Audio recording, recording duration is set to Short Audio recording, recording duration is set to LongAudio recording, recording duration is set to Medium Audio recording, recording duration is set to ShortCall OUT Troubleshooting Description of problem Please consult the followingIs the Lock function or the Password Lock function Specifications JpegPCM Power on Power OFFAlarm OUT Power ON, Power OFF, Alarm IN, Clock ADJ, RECWarranty and Return Information Regulatory Notices