INSTALLATION

1. Connect cameras, monitor, and audio equipment to the recorder as shown in Figure 5.

 

MONITOR

 

To S(Y/C) IN

To peripheral loudspeaker or monitor

terminal

through AUDIO IN terminal

 

CAMERA #1

Up to 9 cameras

To CAMERA IN 1 terminal

MICROPHONE To MIC terminal

AUDIO MIC

IN

OUT

To AUDIO OUT terminal

Either cable can be connected.

To

VIDEO OUT

• • • or

S(Y/C) OUT

terminal

CAMERA IN

1

2

3

4

5

6

7

8

9

 

 

 

 

CAMERA OUT

 

 

 

 

1

2

3

4

5

6

7

8

9

VIDEO

OUT

Y/C

RS-232C

1 2 3 4 5 6 7 8 9

GND

CLOCKADJ

REC

POWERON

POWEROFF

ALARMOUT

MODEOUT

OUTCALL

OUTCALLGND

GND

GND

5VDCOUT

30mAMAX

 

 

 

GND

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

OFF

 

 

ALARM IN

 

 

 

 

 

 

 

 

 

 

 

 

RESET

 

SCSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TERMINATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCSI

To GND

To ALARM IN terminal

terminal

corresponding to the

SENSOR #1

CAMERA #

 

POWER CORD

Figure 5. Equipment Connections (DX3009 Model Shown)

2.Connect alarm inputs and alarm output as shown in Figures 5 and 6. Figure 7 shows schematics for the alarm circuits.

An alarm input is active when a ground or low voltage signal is applied. An input is non-active when the terminal is open.

The alarm output is active when the terminal is at a low voltage level and non-active when the terminal is open. Maximum drive current is 7 mA DC, and the maximum volt- age is +24 VDC.

peripheral alarm lamp or buzzer

GNDGND

ALARM IN

1 2 3 4 5 6 7 8 9

GND CLOCK ADJ

REC

POWER ON

POWER OFF

ALARM OUT

MODE OUT

CALL OUT

CALL OUT GND

GND GND

DC 5V OUT MAX 30mA

alarm switch

Figure 6. Alarm Input and Output Connections

12

Pelco Manual C681M-D (2/02)

Image 13
Contents Changing Password Entering Initial PasswordPassword Error Turning Password Lock On and OffUL Listed Contents Changing Playback Interval Fast FORWARD/REWIND Searching Using the Copy ButtonList of Illustrations Important Safeguards and Warnings Description OverviewGB PER Unit Timer REC button Power buttonModels Front Panel ControlsDET indicator Recording indicators Timer REC indicatorPRE Alarm REC indicator Multiplexer buttons Camera number buttons Lock indicator Mode indicators Access indicator SET UP button Copy indicatorRear Panel Connectors RS-232C connector AC power socketAlarm in terminals Power on terminalCamera #1 InstallationSchematics for Alarm Input and Output Terminals Schematics for Input and Output Terminals HDD DVD-RAMIomega Z250S Adding a Hard Drives Adding or Removing a Copy or Archive DeviceRemoving a Hard Drives BOOT-UP DelayConfirming That a Device is Connected Programming SET UPMenu Tree, DX3009 Models Pelco Manual C681M-D 2/02 Menu Tree, DX3016 Models Menu Tree, DX3016 Models Pelco Manual C681M-D 2/02 Maximum Recording Fields Alarms Image QualityBASIC, STANDARD, MEDIUM, HIGH, Superior Define Group Setting Record Alarm Alarm Recording DurationALL, SEP PRE-ALARM RecordingOFF, SHORT, MEDIUM, Long Archive Pointer Reset DET SettingArchive Data Overwrite Auto Eject Audio RecordingKEY, WRNG, REMAIN, OFF BuzzerCapacity Remaining Call OUTHDD, ARC, None Data Clear Erase SelectionBackup Following a Power Failure FIFO/OVERWRITE Mode DX3016 Models OnlyHard Disk Drive HDD Full Hard Disk Drive HDD Repeat Playback IM-CHECK ModeInitialize Menus Mode OUTMotion Detection REC, PLAY, POWER, RemainLOW, LOWER, HIGHER, HIGH, MED Multiplexer Display Screen Switch Pattern DX3016 Models Only Four-Camera Split 4 SettingSplit 9 Screen Setting DX3016 Models Only Split 4 Screen Setting DX3016 Models OnlySplit 16 Screen Setting DX3016 Models Only Channel Title Displaying Camera Title and/or Number SequenceNONE, TITLE, CH. no Alarm DisplayCamera Title Power FailureRecord Image Quality Maximum Recording Fields Define Group Select Recording ModeRS-232C Communication Saving Menu Data Saving Menu SettingsRestoring Menu Data Time and Date Display Display Mode TCP/IP Setting DX3016 Models OnlyCharacter Size Clock Location Time and Date SettingTitle Timer Recording Repeat steps 8-10 for the ending time C, SKIP, ARC, PowerSetting for the prioritized Program #2 Motion Detection During a Timer Recording DX3016 Models Only Estimating Recording Time SAT OperationSPLIT/SEQUENCE Button Viewing CamerasDX3009 Models DX3009 Models Nine camerasRemote Viewing Zoom ButtonsRecording Basic Recording Alarm Recording Playback Basic Playback Timer Recording in the Programming sectionRegular Playback Mode Adjusting Playback SpeedFRAME-BY-FRAME Still Frame Playback Pause PlaybackFast FORWARD/REWIND Changing Playback IntervalSearching Index Search Skip Search Jump to Starting Point Alarm List SearchPlayback on Another Device Using the Archive ButtonBacking UP Data Using the Copy Button Auto-Eject at the Completion of BackupSimultaneous Recording and Backup Still-Frame Playback Copy ModeDX3016 Models Restoring Data from a Backup Device Information Elapsed Time Display Power Failure ListRecorded Period ResetScsi Devices Connected Audio recording time table DX3009 Recording Time TablesWithout Audio recording Audio recordingDX3009 Recording Time Tables Audio recording, Pre-Alarm Recording duration is set to Long Basic DX3016 Recording Time TablesAudio recording, recording duration is set to Long Without Audio recording, recording duration is set to ShortAudio recording, recording duration is set to Short Audio recording, recording duration is set to MediumCall OUT Description of problem Please consult the following TroubleshootingIs the Lock function or the Password Lock function Jpeg SpecificationsPCM Power OFF Power onAlarm OUT Power ON, Power OFF, Alarm IN, Clock ADJ, RECRegulatory Notices Warranty and Return Information