Pelco DX3016-120, DX3016-060, DX3009-060 manual Hard Disk Drive HDD Full

Page 34

HARD DISK DRIVE (HDD) FULL

When the end of the hard disk drive (HDD) is reached during recording, this function deter- mines what the recorder will do.

Skip steps 1 and 2 if they have already been done.

1.Press the SET UP button to display the Menu Setting menu.

2.Turn the JOG dial to move the cursor to INITIAL SET UP, and then turn the SHUTTLE ring to the right. The Initial Set Up menu appears.

3.Turn the JOG dial until the cursor is next to HDD FULL, and then turn the SHUTTLE ring to the right. The option starts flashing.

NOTE: If the PRE A-REC field in the A-Rec/M-Det Setting menu has been set to SHORT, MEDIUM, or LONG, the option does not flash because it cannot be changed.

4.Turn the JOG dial to select the option, and then turn the SHUTTLE ring to the right. The option stops flashing.

Turning the JOG dial switches the hard drive options as follows:

REC•STANDBY (Recording standby): The unit stops recording when the hard disk is full. The unit overwrites the hard disk when the unit receives an alarm signal, a REC terminal signal, or when the REC button is pushed.

Select this option if the REC terminal is wired to the MODE OUT terminal of another recorder.

REPEAT: When the disk reaches the end during recording, the recording starts again from the beginning of the disk.

ALARM•PROT (Alarm protection): If there is any alarm recording, the unit stops re- cording when the hard disk is full and displays the HDD FULL message on the monitor. When WRNG is entered as the BUZZER value (found in the Rear Terminal menu), the buzzer is also activated. A signal is sent from the CALL OUT terminal when the CALL OUT value (found in the Rear Terminal menu) is reached. If there are no alarm record- ings, the unit continues recording by automatically overwriting the hard disk.

If the CALL OUT terminal is wired to the REC input of another recorder, the other re- corder begins recording when the call out signal is sent.

STOP: The unit stops recording when the hard disk is full and displays the HDD FULL message on the monitor. When WRNG is entered as the BUZZER value (found in the Rear Terminal menu), the buzzer is also activated. The unit stops recording when there is no more storage space in memory. A signal is sent from the CALL OUT terminal when the CALL OUT value (found in the Rear Terminal menu) is reached. To restart overwriting on the hard disk, press the WARNING RESET button to cancel HDD FULL, and then press the REC button.

If the CALL OUT terminal is wired to the REC input of another recorder, the other re- corder begins recording when the call out signal is sent.

5.Do one of the following:

Turn the JOG dial to go to another item in this menu.

Turn the SHUTTLE ring to the left to return to the Menu Setting menu to go to an- other menu.

Press the SET UP button to exit the programming mode.

Pelco Manual C681M-D (2/02)

33

Image 34
Contents Password Error Entering Initial PasswordChanging Password Turning Password Lock On and OffUL Listed Contents Using the Copy Button Changing Playback Interval Fast FORWARD/REWIND SearchingList of Illustrations Important Safeguards and Warnings Description OverviewGB PER Unit Models Power buttonTimer REC button Front Panel ControlsPRE Alarm REC indicator Recording indicators Timer REC indicatorDET indicator Multiplexer buttons Camera number buttonsSET UP button Mode indicators Access indicatorLock indicator Copy indicatorRear Panel Connectors Alarm in terminals AC power socketRS-232C connector Power on terminalInstallation Camera #1Schematics for Alarm Input and Output Terminals Schematics for Input and Output Terminals HDD DVD-RAMIomega Z250S Adding or Removing a Copy or Archive Device Adding a Hard DrivesRemoving a Hard Drives BOOT-UP DelayConfirming That a Device is Connected SET UP ProgrammingMenu Tree, DX3009 Models Pelco Manual C681M-D 2/02 Menu Tree, DX3016 Models Menu Tree, DX3016 Models Pelco Manual C681M-D 2/02 Maximum Recording Fields Alarms Image QualityBASIC, STANDARD, MEDIUM, HIGH, Superior Define Group Setting Alarm Recording Duration Record AlarmALL, SEP PRE-ALARM RecordingOFF, SHORT, MEDIUM, Long Archive Pointer Reset DET SettingArchive Data Overwrite Audio Recording Auto EjectBuzzer KEY, WRNG, REMAIN, OFFCall OUT Capacity RemainingData Clear Erase Selection HDD, ARC, NoneFIFO/OVERWRITE Mode DX3016 Models Only Backup Following a Power FailureHard Disk Drive HDD Full IM-CHECK Mode Hard Disk Drive HDD Repeat PlaybackMode OUT Initialize MenusREC, PLAY, POWER, Remain Motion DetectionLOW, LOWER, HIGHER, HIGH, MED Multiplexer Display Four-Camera Split 4 Setting Screen Switch Pattern DX3016 Models OnlySplit 4 Screen Setting DX3016 Models Only Split 9 Screen Setting DX3016 Models OnlySplit 16 Screen Setting DX3016 Models Only Sequence Channel Title Displaying Camera Title and/or NumberAlarm Display NONE, TITLE, CH. noCamera Title Power FailureRecord Image Quality Maximum Recording Fields Select Recording Mode Define GroupRS-232C Communication Saving Menu Data Saving Menu SettingsRestoring Menu Data TCP/IP Setting DX3016 Models Only Time and Date Display Display ModeCharacter Size Clock Location Time and Date SettingTitle Timer Recording C, SKIP, ARC, Power Repeat steps 8-10 for the ending timeSetting for the prioritized Program #2 Motion Detection During a Timer Recording DX3016 Models Only Estimating Recording Time Operation SATDX3009 Models Viewing CamerasSPLIT/SEQUENCE Button DX3009 Models Nine camerasRemote Viewing Zoom ButtonsRecording Basic Recording Alarm Recording Timer Recording in the Programming section Playback Basic PlaybackFRAME-BY-FRAME Still Frame Playback Adjusting Playback SpeedRegular Playback Mode Pause PlaybackFast FORWARD/REWIND Changing Playback IntervalSearching Index Search Skip Search Alarm List Search Jump to Starting PointPlayback on Another Device Using the Archive ButtonBacking UP Data Auto-Eject at the Completion of Backup Using the Copy ButtonSimultaneous Recording and Backup Still-Frame Playback Copy ModeDX3016 Models Restoring Data from a Backup Device Power Failure List Information Elapsed Time DisplayRecorded Period ResetScsi Devices Connected Without Audio recording DX3009 Recording Time TablesAudio recording time table Audio recordingDX3009 Recording Time Tables Audio recording, Pre-Alarm Recording duration is set to Long DX3016 Recording Time Tables BasicWithout Audio recording, recording duration is set to Short Audio recording, recording duration is set to LongAudio recording, recording duration is set to Medium Audio recording, recording duration is set to ShortCall OUT Troubleshooting Description of problem Please consult the followingIs the Lock function or the Password Lock function Jpeg SpecificationsPCM Alarm OUT Power onPower OFF Power ON, Power OFF, Alarm IN, Clock ADJ, RECWarranty and Return Information Regulatory Notices