HARD DISK DRIVE (HDD) FULL
When the end of the hard disk drive (HDD) is reached during recording, this function deter- mines what the recorder will do.
Skip steps 1 and 2 if they have already been done.
1.Press the SET UP button to display the Menu Setting menu.
2.Turn the JOG dial to move the cursor to INITIAL SET UP, and then turn the SHUTTLE ring to the right. The Initial Set Up menu appears.
3.Turn the JOG dial until the cursor is next to HDD FULL, and then turn the SHUTTLE ring to the right. The option starts flashing.
NOTE: If the PRE
4.Turn the JOG dial to select the option, and then turn the SHUTTLE ring to the right. The option stops flashing.
Turning the JOG dial switches the hard drive options as follows:
REC•STANDBY (Recording standby): The unit stops recording when the hard disk is full. The unit overwrites the hard disk when the unit receives an alarm signal, a REC terminal signal, or when the REC button is pushed.
Select this option if the REC terminal is wired to the MODE OUT terminal of another recorder.
REPEAT: When the disk reaches the end during recording, the recording starts again from the beginning of the disk.
ALARM•PROT (Alarm protection): If there is any alarm recording, the unit stops re- cording when the hard disk is full and displays the HDD FULL message on the monitor. When WRNG is entered as the BUZZER value (found in the Rear Terminal menu), the buzzer is also activated. A signal is sent from the CALL OUT terminal when the CALL OUT value (found in the Rear Terminal menu) is reached. If there are no alarm record- ings, the unit continues recording by automatically overwriting the hard disk.
If the CALL OUT terminal is wired to the REC input of another recorder, the other re- corder begins recording when the call out signal is sent.
STOP: The unit stops recording when the hard disk is full and displays the HDD FULL message on the monitor. When WRNG is entered as the BUZZER value (found in the Rear Terminal menu), the buzzer is also activated. The unit stops recording when there is no more storage space in memory. A signal is sent from the CALL OUT terminal when the CALL OUT value (found in the Rear Terminal menu) is reached. To restart overwriting on the hard disk, press the WARNING RESET button to cancel HDD FULL, and then press the REC button.
If the CALL OUT terminal is wired to the REC input of another recorder, the other re- corder begins recording when the call out signal is sent.
5.Do one of the following:
•Turn the JOG dial to go to another item in this menu.
•Turn the SHUTTLE ring to the left to return to the Menu Setting menu to go to an- other menu.
•Press the SET UP button to exit the programming mode.