4.Turn the JOG dial to select the option, and then turn the SHUTTLE ring to the right. The option stops flashing.
Turning the JOG dial switches the mode out options as follows:
REC, PLAY, POWER, REMAIN
REC: The signal is output during recording.
PLAY: The signal is output during playback.
POWER: The signal is output when the recorder’s power switch is on.
REMAIN: The signal is output when the remaining storage capacity of main hard drive, archive device, or copy device reaches the rate which is set in the CAPACITY REMAIN field of the Rear Terminal menu.
Select REMAIN if the MODE OUT terminal is wired to the record (REC) input of an- other recorder.
5.Do one of the following:
•Turn the JOG dial to go to another item in this menu.
•Turn the SHUTTLE ring to the left to return to the Menu Setting menu to go to an- other menu.
•Press the SET UP button to exit the programming mode.
MOTION DETECTION
NOTE: To set up motion detection to operate during a specified time period (DX3016 models only), refer to the section on Motion Detection During a Timer Recording.
These settings are used to initiate alarm recording when movement is detected within the images captured by the cameras.
Skip steps 1 and 2 if they have already been done.
1.Press the SET UP button to display the Menu Setting menu.
2.Turn the JOG dial to move the cursor to INITIAL SET UP, and then turn the SHUTTLE ring to the right. The Initial Set Up menu appears.
3.Turn the JOG dial to select MOTION DETECTION, and then turn the SHUTTLE ring to the right. The option starts flashing.
NOTE: If the PRE
4.Turn the JOG dial to select ON or OFF, and then turn the SHUTTLE ring to the right. The option stops flashing.
If you selected ON, proceed to step 5.
If you selected OFF, turn the SHUTTLE ring to the left to return to the Menu Setting menu to go to another menu, or press the SET UP button to exit the programming mode.
5.Turn the SHUTTLE ring to the left to return to the Menu Setting menu.
6.Turn the JOG dial to select
NOTE: The image quality, maximum recording fields, and alarm recording dura- tion in the