Pelco DX3016-120, DX3016-060, DX3009-060 manual Alarm List Search, Jump to Starting Point

Page 67

Alarm List Search

The Alarm List search retrieves alarm video at the time an alarm occurred. It does not re- trieve pre-alarm recording if the pre-alarm recording option was turned on (PRE A-REC field in the A-Rec/M-Det Setting menu).

Up to 500 alarm times (DX3009 models) or 800 alarm times (DX3016 models) can be stored in the alarm list. After the 500th time (DX3009 models) or 801st time (DX3016 models), the first alarm time is erased and the 501st (or 801st) alarm time is added to the list.

1.Press the SEARCH button to display the Search Selection menu.

2.Make sure the cursor is next to SELECTION CAMERA NO., and then turn the SHUTTLE ring to the right. The option starts flashing.

3.Turn the JOG dial to select the option, and then turn the SHUTTLE ring to the right. The option stops flashing.

Turning the JOG dial switches the options as follows:

DX3009 Models – ALL, 1, 2, 3, 4, 5, 6, 7, 8, 9

DX3016 Models – ALL, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16

4.Turn the JOG dial to move the cursor to ALARM LIST SEARCH, and then turn the SHUTTLE ring to the right to display the Alarm List Search menu.

5.Turn the JOG dial until the cursor is at the desired alarm list number. When the cursor reaches either the top or the bottom of the list, the Alarm List Search menu scrolls to the next page. To move through the pages, place the cursor over “No.”, and then turn the SHUTTLE ring.

6.Turn the SHUTTLE ring to the right. The unit begins the alarm list search and retrieves the image associated with the selected time.

NOTE: If the PRE A-REC field in the A-Rec/M-Det Setting menu has been set to SHORT, MEDIUM, or LONG, the search cannot be done.

Images appear in a 9-camera display (DX3009 models) or 16-camera display (DX3016 models) if ALL was selected or on a single screen if an individual camera was selected. The PLAY and PAUSE buttons light.

7.Press the SEARCH button to clear the Alarm List from the screen.

8.To change the 9-camera display (DX3009 models) or 16-camera display (DX3016 models) to a single-camera display, press the CAMERA number button on the front of the recorder. The display for the single camera appears.

9.Press the PLAY or PAUSE button to play back the searched image.

10.Press the STOP button to stop playback and exit the search function.

Jump to Starting Point

Select this option to play back the oldest recorded data.

1.Press the SEARCH button to display the Search Selection menu.

2.Turn the JOG dial to move the cursor to JUMP TO START POINT, and then turn the SHUTTLE ring to the right. The Jump to Start Point screen appears.

3.Turn the SHUTTLE ring to the right. The recorder displays the oldest recordings on a

9-camera screen (DX3009 models) or 16-camera screen (DX3016 models). The PLAY and PAUSE buttons light.

4.To change the 9-camera display (DX3009 models) or 16-camera display (DX3016 models) to a single-camera display, press the CAMERA number button on the front of the recorder. The display for the single camera appears.

66

Pelco Manual C681M-D (2/02)

Image 67
Contents Turning Password Lock On and Off Entering Initial PasswordChanging Password Password ErrorUL Listed Contents Changing Playback Interval Fast FORWARD/REWIND Searching Using the Copy ButtonList of Illustrations Important Safeguards and Warnings Description OverviewGB PER Unit Front Panel Controls Power buttonTimer REC button ModelsMultiplexer buttons Camera number buttons Recording indicators Timer REC indicatorDET indicator PRE Alarm REC indicatorCopy indicator Mode indicators Access indicatorLock indicator SET UP buttonRear Panel Connectors Power on terminal AC power socketRS-232C connector Alarm in terminalsCamera #1 InstallationSchematics for Alarm Input and Output Terminals Schematics for Input and Output Terminals HDD DVD-RAMIomega Z250S Adding a Hard Drives Adding or Removing a Copy or Archive DeviceRemoving a Hard Drives BOOT-UP DelayConfirming That a Device is Connected Programming SET UPMenu Tree, DX3009 Models Pelco Manual C681M-D 2/02 Menu Tree, DX3016 Models Menu Tree, DX3016 Models Pelco Manual C681M-D 2/02 Maximum Recording Fields Alarms Image QualityBASIC, STANDARD, MEDIUM, HIGH, Superior Define Group Setting Record Alarm Alarm Recording DurationALL, SEP PRE-ALARM RecordingOFF, SHORT, MEDIUM, Long Archive Pointer Reset DET SettingArchive Data Overwrite Auto Eject Audio RecordingKEY, WRNG, REMAIN, OFF BuzzerCapacity Remaining Call OUTHDD, ARC, None Data Clear Erase SelectionBackup Following a Power Failure FIFO/OVERWRITE Mode DX3016 Models OnlyHard Disk Drive HDD Full Hard Disk Drive HDD Repeat Playback IM-CHECK ModeInitialize Menus Mode OUTMotion Detection REC, PLAY, POWER, RemainLOW, LOWER, HIGHER, HIGH, MED Multiplexer Display Screen Switch Pattern DX3016 Models Only Four-Camera Split 4 SettingSplit 9 Screen Setting DX3016 Models Only Split 4 Screen Setting DX3016 Models OnlySplit 16 Screen Setting DX3016 Models Only Channel Title Displaying Camera Title and/or Number SequenceNONE, TITLE, CH. no Alarm DisplayCamera Title Power FailureRecord Image Quality Maximum Recording Fields Define Group Select Recording ModeRS-232C Communication Saving Menu Data Saving Menu SettingsRestoring Menu Data Time and Date Display Display Mode TCP/IP Setting DX3016 Models OnlyCharacter Size Clock Location Time and Date SettingTitle Timer Recording Repeat steps 8-10 for the ending time C, SKIP, ARC, PowerSetting for the prioritized Program #2 Motion Detection During a Timer Recording DX3016 Models Only Estimating Recording Time SAT OperationDX3009 Models Nine cameras Viewing CamerasSPLIT/SEQUENCE Button DX3009 ModelsRemote Viewing Zoom ButtonsRecording Basic Recording Alarm Recording Playback Basic Playback Timer Recording in the Programming sectionPause Playback Adjusting Playback SpeedRegular Playback Mode FRAME-BY-FRAME Still Frame PlaybackFast FORWARD/REWIND Changing Playback IntervalSearching Index Search Skip Search Jump to Starting Point Alarm List SearchPlayback on Another Device Using the Archive ButtonBacking UP Data Using the Copy Button Auto-Eject at the Completion of BackupSimultaneous Recording and Backup Still-Frame Playback Copy ModeDX3016 Models Restoring Data from a Backup Device Information Elapsed Time Display Power Failure ListRecorded Period ResetScsi Devices Connected Audio recording DX3009 Recording Time TablesAudio recording time table Without Audio recordingDX3009 Recording Time Tables Audio recording, Pre-Alarm Recording duration is set to Long Basic DX3016 Recording Time TablesAudio recording, recording duration is set to Long Without Audio recording, recording duration is set to ShortAudio recording, recording duration is set to Short Audio recording, recording duration is set to MediumCall OUT Description of problem Please consult the following TroubleshootingIs the Lock function or the Password Lock function Jpeg SpecificationsPCM Power ON, Power OFF, Alarm IN, Clock ADJ, REC Power onPower OFF Alarm OUTRegulatory Notices Warranty and Return Information