Pelco DX3016-060 Power on, Power OFF, Clock ADJ, Rec, Gnd, Alarm OUT, DC 5V OUT, Call OUT Ground

Page 84

Inputs/Outputs

 

POWER ON:

Input for power ON. Low input state is power off; high input

 

state is power on.

POWER OFF:

Input for power OFF. Low input state is power off.

ALARM IN (1-9):

Inputs for starting alarm recording. Active: When terminals

 

are short-circuited or “Low” Level voltage is applied.

 

Non active: Open.

CLOCK ADJ:

Input for adjusting clock. Active: When terminals are short-

 

circuited or “Low” Level voltage is applied. Non active: Open.

REC:

Input to start recording. Active: When terminals are short-

 

circuited or “Low” Level voltage is applied. Non active: Open.

GND:

Ground.

ALARM OUT:

Output for use while alarm recording is under way.

 

Active: “Low” Level. Maximum drive current: 7 mA DC.

MODE OUT:

Output for indication of selected recording mode.

 

Non-active: Open. Maximum voltage: +24V DC.

DC 5V OUT:

Output for DC 5V OUT.

CALL OUT:

Output for external warning device. Active: ON. Maximum

 

drive current: 7 mA DC.

CALL OUT GROUND:

Ground for external warning device. Non active: Open.

 

Maximum voltage: +24VDC.

GENERAL

 

Operating Temperature:

41° to 104°F (5° to 40°C).

Relative Humidity:

Maximum 80%

Dimensions:

16.7 (W) x 15.0 (D) x 4.45 (H) inches

 

(42.5 x 38.0 x 11.3 cm)

Unit Weight

 

DX3009 models:

15.7 lb (7.1 kg)

DX3016 models:

17.9 lb (8.1 kg)

Connectors

 

Push-in terminal:

POWER ON, POWER OFF, ALARM IN, CLOCK ADJ, REC

 

inputs

 

Ground, CALL OUT ground

 

ALARM OUT, MODE OUT, DC 5V OUT, CALL OUT outputs

BNC:

Video input/output

SVHS:

Video output

DB9:

RS-232C for connection with personal computer

50-pin D-type:

SCSI

(Design and product specifications subject to change without notice.)

Pelco Manual C681M-D (2/02)

83

Image 84
Contents Entering Initial Password Changing PasswordPassword Error Turning Password Lock On and OffUL Listed Contents Using the Copy Button Changing Playback Interval Fast FORWARD/REWIND SearchingList of Illustrations Important Safeguards and Warnings Overview DescriptionGB PER Unit Power button Timer REC buttonModels Front Panel ControlsRecording indicators Timer REC indicator DET indicatorPRE Alarm REC indicator Multiplexer buttons Camera number buttonsMode indicators Access indicator Lock indicatorSET UP button Copy indicatorRear Panel Connectors AC power socket RS-232C connectorAlarm in terminals Power on terminalInstallation Camera #1Schematics for Alarm Input and Output Terminals Schematics for Input and Output Terminals DVD-RAM HDDIomega Z250S Adding or Removing a Copy or Archive Device Adding a Hard DrivesBOOT-UP Delay Removing a Hard DrivesConfirming That a Device is Connected SET UP ProgrammingMenu Tree, DX3009 Models Pelco Manual C681M-D 2/02 Menu Tree, DX3016 Models Menu Tree, DX3016 Models Pelco Manual C681M-D 2/02 Alarms Image Quality Maximum Recording FieldsBASIC, STANDARD, MEDIUM, HIGH, Superior Define Group Setting Alarm Recording Duration Record AlarmPRE-ALARM Recording ALL, SEPOFF, SHORT, MEDIUM, Long DET Setting Archive Pointer ResetArchive Data Overwrite Audio Recording Auto EjectBuzzer KEY, WRNG, REMAIN, OFFCall OUT Capacity RemainingData Clear Erase Selection HDD, ARC, NoneFIFO/OVERWRITE Mode DX3016 Models Only Backup Following a Power FailureHard Disk Drive HDD Full IM-CHECK Mode Hard Disk Drive HDD Repeat PlaybackMode OUT Initialize MenusREC, PLAY, POWER, Remain Motion DetectionLOW, LOWER, HIGHER, HIGH, MED Multiplexer Display Four-Camera Split 4 Setting Screen Switch Pattern DX3016 Models OnlySplit 4 Screen Setting DX3016 Models Only Split 9 Screen Setting DX3016 Models OnlySplit 16 Screen Setting DX3016 Models Only Sequence Channel Title Displaying Camera Title and/or NumberAlarm Display NONE, TITLE, CH. noPower Failure Camera TitleRecord Image Quality Maximum Recording Fields Select Recording Mode Define GroupRS-232C Communication Saving Menu Settings Saving Menu DataRestoring Menu Data TCP/IP Setting DX3016 Models Only Time and Date Display Display ModeCharacter Size Time and Date Setting Clock LocationTitle Timer Recording C, SKIP, ARC, Power Repeat steps 8-10 for the ending timeSetting for the prioritized Program #2 Motion Detection During a Timer Recording DX3016 Models Only Estimating Recording Time Operation SATViewing Cameras SPLIT/SEQUENCE ButtonDX3009 Models DX3009 Models Nine camerasZoom Buttons Remote ViewingRecording Basic Recording Alarm Recording Timer Recording in the Programming section Playback Basic PlaybackAdjusting Playback Speed Regular Playback ModeFRAME-BY-FRAME Still Frame Playback Pause PlaybackChanging Playback Interval Fast FORWARD/REWINDSearching Index Search Skip Search Alarm List Search Jump to Starting PointUsing the Archive Button Playback on Another DeviceBacking UP Data Auto-Eject at the Completion of Backup Using the Copy ButtonStill-Frame Playback Copy Mode Simultaneous Recording and BackupDX3016 Models Restoring Data from a Backup Device Power Failure List Information Elapsed Time DisplayReset Recorded PeriodScsi Devices Connected DX3009 Recording Time Tables Audio recording time tableWithout Audio recording Audio recordingDX3009 Recording Time Tables Audio recording, Pre-Alarm Recording duration is set to Long DX3016 Recording Time Tables BasicWithout Audio recording, recording duration is set to Short Audio recording, recording duration is set to LongAudio recording, recording duration is set to Medium Audio recording, recording duration is set to ShortCall OUT Troubleshooting Description of problem Please consult the followingIs the Lock function or the Password Lock function Specifications JpegPCM Power on Power OFFAlarm OUT Power ON, Power OFF, Alarm IN, Clock ADJ, RECWarranty and Return Information Regulatory Notices