Sterling 882.00249.00 manual Appendix, Warranty Specifications, Warranty Restrictions

Page 50

Chapter 7: Appendix

7-1 Warranty

Unless otherwise specified, this product includes a Standard ONE YEAR PARTS AND LABOR WARRANTY.

Warranty Specifications

The manufacturer hereby expressly warrants all equipment manufactured by it to be free from defects in workmanship and material when used under recommended conditions, as set forth in the operating manuals for such equipment. THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, GUARANTIEES, AGREEMENTS, AND SIMILAR OBLIGATIONS OF THE COMPANY AND/OR MANUFACTURER (UNLESS OTHERWISE SPECIFIED IN THE SPECIFIC PRICE PAGE OR LIMITED BY THE MANUFACTURERS’ WARRANTY FOR PARTS). The Company’s obligation is limited to repair or replace FOB the factory any parts that are returned, prepaid, within one year of equipment shipment to the original purchaser, and which in the Company’s opinion, are defective. Any replacement part assumes the unused portion of this warranty.

Warranty Restrictions

This parts warranty does not cover any labor charges for replacement of parts, adjustment repairs, or any other work. This warranty does not apply to any equipment which, in the Company’s opinion, has been subjected to misuse, negligence, or operation in excess of recommended limits, including freezing or which has been repaired or altered without the Company’s express authorization. If the serial number has been defaced or removed from the component, the warranty on that component is void. Defective parts become the property of the warrantor and are to be returned immediately, without any further use or handling.

2–Pump 12-Station Controllers

Chapter 7: Appendix

49

Image 50
Contents SCC 2-Pump 12-Station Controllers Write Down Your Serial Numbers Here For Future ReferenceParts and Service Department Event of Shipping Damage Shipping InformationUnpacking and Inspection If the Shipment is Not CompleteCredit Returns Warranty ReturnsReturns Table of Contents Maintenance Safety Symbols Used in this Manual SafetyHow to Use This Manual Controller Safety Tags Wear Safety Glasses and Work GlovesResponsibility General ResponsibilityOperator Responsibility Maintenance ResponsibilityReporting a Safety Defect General Description Functional DescriptionModels Covered in This Manual Mechanical Features Standard FeaturesOptional Features Electrical FeaturesSafety Device Lock-Outs Safety Devices and InterlocksSafety Circuit Standards Fail Safe OperationPump 12-Station Controllers Functional Description Uncrating InstallationMaking Control Panel Power Drop Wiring Connections Mounting the Control PanelConnecting the Control Panel to Vacuum Hoppers Connecting the Control Panel to the Pump PackageTypical 24-Volt Junction Box Wiring Diagram DC Controller Power Sources SetupMain Power InputsGaining Access to the Menu System Menu Tree StructureOperation Mode, Station Settings Menu Station SETTINGS? NO/YESStation Settings Menu Operation MODE? NO/YESStation 1 Normal =NORMAL N=SIGHTGLS ALL Normal MODE? NO/YESALL Sightglass MODE? NO/YES Set Dump Delay, Station Settings Menu SET Dump DELAY? NO/YESDump Delay 11 15.0s To Select a Station Press StationSET Input DELAY? NO/YES Set Input Delay, Station Settings MenuInput DLY 11 0.250s SET Station ALARMS? NO/YESSet Station Alarms, Station Settings Menu Alarm 11 Enabled =ENABLE N=DISABLE To Select a Station Press Hopper Alarm After 3 Loads Press Enter to SaveAssign PUMPSTATION? NO/YES Assigning a Pump to a StationStation 10 Pump Select Pump 1 or Setting the Pump Mode Pump SETTINGS? NO/YESPump Settings Menu Pump MODE? NO/YESSET Active Pump Select Pump 1 or Changing Blowback Settings, Pump Settings Menu Blowback SETTINGS? NO/YESEnable BLOWBACK? NO/YES Select Pump 1 or USE Keypad to EnterOFF Time 0.500 s Blowback Pulses Setting for PumpOn Time 0.500 s Idle Delay Time Settings, Pump Settings Menu Blbk After 12 Loads Setting for PumpIdle Delay TIME? NO/YES System Settings Menu Idle Time 10.000 sService Settings Menu Saving Controller Settings to Flash MemoryOperation Load Time 10 63secText Area SectionController Description and Operation STATION-- Offline Time --- Logo Pump Modes Single Pump ModeDual Pump Mode P1S----- Offline P2S----- OfflineStation Icons Station Icon Segments Label DescriptionStatus Indicators Status Indicator Icons Label DescriptionLabel Description Controller KeypadKey Descriptions Operation Operation StatesRuns but no station loads Shut-Down Maintenance Updating Bios SoftwareBios Connection, Electrical Diagram Drawing A0560970LEGEND Troubleshooting General TroubleshootingSee -5 on Page 75 for Writing Parameters To FLASH-PLEASE Wait Saving Backup Controller Recovery using Flash Memory TechnologyWarranty Restrictions WarrantyWarranty Specifications AppendixWarranty Liabilities Customer ResponsibilitiesDrawings and Diagrams Pump 12 station Controller Control PanelSpare Parts List Places A0560974 Power cord A0560954ENCL, CARLON, Mount FLNG, MNK10L A0560974 RECT, BRIDGE, 25 AMPS, GBPC2510 Controller Identification Serial Number Tag Technical Assistance Contact InformationService Settings Menu Service Only InformationRamp UP DLY 1.500s Setting for Pump n Setting the Ramp Up TimeSET Ramp Down TIME? NO/YES Ramp DN DLY 8.000s Setting for Pump nSetting the Ramp Down Time SET Pump Stage TIME? NO/YES Stage Delay 3.000sSetting the Pump Stage Time Setting the LCD Blink Delay SET LCD Blink DELAY? NO/YESBlink Delay .500s Setting the Hi Vacuum Sensor Delay HI VAC Sensor DELAY? NO/YESHivac Delay 3.000s Setting for Pump n Setting the Hi Vacuum Vent Delay HI VAC Vent DELAY? NO/YESHV Vent DLY 10.000s Setting for Pump n HV Load CNT Setting the Hi Vacuum Load CountHI VAC Load COUNT? NO/YES BNK0 BNK1 Using the Installation Aids MenusInput MONITOR? NO/YES Input Monitor ScreenOutput Control Menu Output CONTROL? NO/YESAutomatic or MANUAL? =AUTO Y=MANUAL OUTBNK0 OUTBNK1 Using the OEM Service Menu OEM Menu Access Is NOW AvailableOEM SETTINGS? NO/YES Other Controller Restricted AreasRecovering Passwords PWL11111 PWL22222 PWL33333 PWL44444Press YES to Resume Restoring the Controller to Factory DefaultsROM Checksum Verifying Software Checksums