Sterling 882.00249.00 manual HI VAC Vent DELAY? NO/YES, HV Vent DLY 10.000s Setting for Pump n

Page 63

Setting the Hi Vacuum Vent Delay

Hi vacuum vent delay is the vent time initiated by a high vacuum condition. This delay defaults to 10.0 seconds and should not be altered unless you are instructed to do so by the Service Department.

HI VAC VENT DELAY?

NO/YES

At the above message prompt:

1. Press the YES key to enter the Hi Vacuum Vent Delay Time menu.

SELECT PUMP 1 OR 2

USE KEYPAD TO ENTER

At the above screen prompt:

2.Select the pump for altering vacuum vent delay. The following screen displays.

HV VENT DLY: 10.000s

SETTING FOR PUMP n

Using the keypad:

3. Enter the new time and press the ENTER key to save the new setting.

2–Pump 12-Station Controllers

Chapter 8: Service Only Information

62

Image 63
Contents Write Down Your Serial Numbers Here For Future Reference SCC 2-Pump 12-Station ControllersParts and Service Department If the Shipment is Not Complete Shipping InformationUnpacking and Inspection Event of Shipping DamageWarranty Returns ReturnsCredit Returns Table of Contents Maintenance Safety How to Use This ManualSafety Symbols Used in this Manual Wear Safety Glasses and Work Gloves Controller Safety TagsGeneral Responsibility ResponsibilityMaintenance Responsibility Reporting a Safety DefectOperator Responsibility Functional Description Models Covered in This ManualGeneral Description Electrical Features Standard FeaturesOptional Features Mechanical FeaturesFail Safe Operation Safety Devices and InterlocksSafety Circuit Standards Safety Device Lock-OutsPump 12-Station Controllers Functional Description Mounting the Control Panel InstallationMaking Control Panel Power Drop Wiring Connections UncratingConnecting the Control Panel to the Pump Package Connecting the Control Panel to Vacuum HoppersTypical 24-Volt Junction Box Wiring Diagram Inputs SetupMain Power DC Controller Power SourcesMenu Tree Structure Gaining Access to the Menu SystemOperation MODE? NO/YES Station SETTINGS? NO/YESStation Settings Menu Operation Mode, Station Settings MenuALL Normal MODE? NO/YES ALL Sightglass MODE? NO/YESStation 1 Normal =NORMAL N=SIGHTGLS To Select a Station Press Station SET Dump DELAY? NO/YESDump Delay 11 15.0s Set Dump Delay, Station Settings MenuSet Input Delay, Station Settings Menu SET Input DELAY? NO/YESSET Station ALARMS? NO/YES Set Station Alarms, Station Settings MenuInput DLY 11 0.250s Alarm 11 Enabled =ENABLE N=DISABLE Assigning a Pump to a Station Alarm After 3 Loads Press Enter to SaveAssign PUMPSTATION? NO/YES To Select a Station Press HopperStation 10 Pump Select Pump 1 or Pump MODE? NO/YES Pump SETTINGS? NO/YESPump Settings Menu Setting the Pump ModeSET Active Pump Select Pump 1 or Select Pump 1 or USE Keypad to Enter Blowback SETTINGS? NO/YESEnable BLOWBACK? NO/YES Changing Blowback Settings, Pump Settings MenuBlowback Pulses Setting for Pump On Time 0.500 sOFF Time 0.500 s Blbk After 12 Loads Setting for Pump Idle Delay TIME? NO/YESIdle Delay Time Settings, Pump Settings Menu Idle Time 10.000 s System Settings MenuSaving Controller Settings to Flash Memory Service Settings MenuLoad Time 10 63sec OperationSection Controller Description and OperationText Area P1S----- Offline P2S----- Offline Pump Modes Single Pump ModeDual Pump Mode STATION-- Offline Time --- LogoStation Icon Segments Label Description Station IconsStatus Indicator Icons Label Description Status IndicatorsController Keypad Key DescriptionsLabel Description Operation States OperationRuns but no station loads Shut-Down Updating Bios Software MaintenanceBios Connection, Electrical Diagram Drawing A0560970LEGEND General Troubleshooting TroubleshootingSee -5 on Page 75 for Controller Recovery using Flash Memory Technology Writing Parameters To FLASH-PLEASE Wait Saving BackupAppendix WarrantyWarranty Specifications Warranty RestrictionsCustomer Responsibilities Warranty LiabilitiesPump 12 station Controller Control Panel Drawings and DiagramsPlaces A0560974 Power cord A0560954 Spare Parts ListENCL, CARLON, Mount FLNG, MNK10L A0560974 RECT, BRIDGE, 25 AMPS, GBPC2510 Technical Assistance Contact Information Controller Identification Serial Number TagSetting the Ramp Up Time Service Only InformationRamp UP DLY 1.500s Setting for Pump n Service Settings MenuRamp DN DLY 8.000s Setting for Pump n Setting the Ramp Down TimeSET Ramp Down TIME? NO/YES Stage Delay 3.000s Setting the Pump Stage Time SET Pump Stage TIME? NO/YES SET LCD Blink DELAY? NO/YES Blink Delay .500sSetting the LCD Blink Delay HI VAC Sensor DELAY? NO/YES Hivac Delay 3.000s Setting for Pump nSetting the Hi Vacuum Sensor Delay HI VAC Vent DELAY? NO/YES HV Vent DLY 10.000s Setting for Pump nSetting the Hi Vacuum Vent Delay Setting the Hi Vacuum Load Count HI VAC Load COUNT? NO/YESHV Load CNT Input Monitor Screen Using the Installation Aids MenusInput MONITOR? NO/YES BNK0 BNK1Output CONTROL? NO/YES Automatic or MANUAL? =AUTO Y=MANUALOutput Control Menu OUTBNK0 OUTBNK1 Other Controller Restricted Areas OEM Menu Access Is NOW AvailableOEM SETTINGS? NO/YES Using the OEM Service MenuPWL11111 PWL22222 PWL33333 PWL44444 Recovering PasswordsVerifying Software Checksums Restoring the Controller to Factory DefaultsROM Checksum Press YES to Resume