FujiFilm HHT145 Set-Up, Install HEPA-TYPE Filters, Operation, Powering Up Fig

Page 3

HHT-145_OM.qxd 11/21/06 5:42 PM Page 3

SET-UP

Select a firm, level and flat location. For proper airflow, locate the unit at least 3 feet (1 M) from any wall or furniture.

When operating, large volumes of air are drawn toward the air purifier. Surrounding areas should be cleaned and/or vacuumed frequently to prevent build-up of dust and other contaminates. This may also help prolong the life of the filter. If the unit is placed on a light colored carpet, a small mat or rug should be used underneath to prevent permanent staining. This is especially important in homes with contamination from smoking, fireplaces or where candles are burned.

Ensure the exit grille (front of the unit) faces away from the closest wall or furniture.

Ensure no grilles are blocked.

INSTALL HEPA-TYPE FILTERS

The HEPA-Type Filters are supplied within the air purifier. They are wrapped to ensure purity.

Make sure the air purifier is turn off and unplugged.

Remove the rear grille by pressing the notch on the top of the rear grille and pulling the grille towards you (Fig. 2).

Remove the filters by gently pushing along the edge of the filter frame and pulling it forward. Repeat for the second filter.

Remove the protective wrap from the filters.

Place the filters back into the air purifier housing and snap the rear grille back into place.

Note that the pre-filter needs to be in position along the rear grille before snapping the grille back into place.

The Top filter must be in place in order for the unit to operate.

Fig. 2

OPERATION

Powering Up: (Fig. 3)

Plug the air purifier into a grounded, working outlet. Once the unit is plugged in, the back-lit Power Button icon ( ) will blink for 12 seconds indicating the unit is ready for operation.

When the Power Button is pressed the following will take place:

°The LCD display and buttons will light up. The Oscillation, on/ off, Timer, and Timer +/– button lights will turn off after 3 seconds. The LCD light will turn off after 8 seconds if no buttons are pressed.

°The UV feature turns on.

°The Ionizer feature turns on.

°The air purifier will operate at a medium cleaning power level for a few seconds and then automatically change to a low level.

°The continuous Run display turns on and rotates.

Fig. 3

UV on/off button

Ionization

on/off buttonOscillation button

Filter reset

UV bulb reset

button

button

 

LCD display

 

Timer

 

+/– button

Cleaning power

 

+/- button

Timer

 

on/off

 

button

 

Power button

Image 3
Contents Read all instructions before operating the air purifier Important Safety InstructionsUnit Fig Your AIR PurifierOdor Control HOW Your AIR Purifier WorksOperation Install HEPA-TYPE FiltersPowering Up Fig SET-UPIonizer, UV and Oscillation Options Changing the Cleaning Power SettingTimer Operation Filter Clean IndicatorDual UV Lamp Operation Oscillation FeatureCleaning the HEPA-TYPE Filters To Clean Your HEPA-Type FilterMaintaining Your Stage 1 Washable Particle PRE-FILTER Optional Changing the Odor Control FilterReplacing the Ultraviolet UV Bulbs Can I wash my HEPA-Type filter? When do the UV bulbs need to be replaced?My unit will not turn on How long should I run my Air Purifier?Consumer Relations Replacement Filters / UV BulbsAccessories and Replacement Filters Hepa Filter N.0101 Note that two 2 filters are requiredCanada Year Limited WarrantySend to U.S.AHHT-145OM.qxd 11/21/06 542 PM Ne pas utiliser le purificateur d’air en plein air Importantes Instructions DE SécuritéLE Purificateur D’AIR Élimination DES OdeursFonctionnement DU Purificateur D’AIR Mise sous tension Fig InstallationInstallation DES Filtres DE Type Hepa FonctionnementFonctionnement de la minuterie Fonctionnement SuiteChangement du réglage de l’intensité de purification Fonctions d’ionisation, de lumière UV et d’oscillationLe bouton UV s’illumine sur le panneau de commande Fonction D’OSCILLATIONFonctionnement DES Deux Ampoules UV Nettoyage DES Filtres DE Type Hepa Pour nettoyer les filtres de type HepaRemarque Les filtres de type Hepa ne sont pas lavables Remarque Le filtre CZ n’est pas lavable Optionnel Remplacement du filtre éliminant les odeursRemplacement DES Ampoules Ultraviolettes UV Entretien DU Préfiltre DE Particules LavableMon appareil ne se met pas en marche Quel moment les ampoules UV doivent-elles être remplacées?Est-ce que je peux laver les filtres de type HEPA? Comment l’indicateur des ampoules UV fonctionne-t-il? Accessoires ET Filtres DE RechangeService À LA Clientèle Foire AUX Questions SuiteGarantie Limitée DE 5 ANS Envoyer àAu Canada Desenchufe el aparato antes de efectuar su mantenimiento Importantes Instrucciones DE SeguridadEL Purificador DE Aire Eliminación DE LOS OloresFuncionamiento DEL Purificador DE Aire Conexión a la corriente Fig InstalaciónInstalación DE LOS Filtros Hepa FuncionamientoFuncionamiento del temporizador Funcionamiento ContinuaciónPara regular la intensidad de purificación Funciones de ionización, de luz UV y de oscilaciónPulse el botón UV para encender o apagar las lámparas Fig Solo segmentoFunción DE Oscilación Funcionamiento DE LAS DOS Lámparas UVLimpieza DE LOS Filtros Hepa Para limpiar los filtros HepaNota los filtros Hepa no son lavables Para Cambiar LAS Lámparas Ultravioleta UV Mantenimiento DEL Prefiltro DE Partículas LavableOpcional cambio del filtro elimina-olores Nota el filtro CZ no es lavableMi aparato no se prende ¿Cuándo deben cambiarse las lámparas UV?¿Puedo lavar los filtros HEPA? ¿Cómo funciona el indicador de las lámparas UV? ¿Cómo funciona el indicador electrónico del filtro?Garantía Limitada DE 5 Años En Estados UnidosEn Canadá