MAINTAINING YOUR STAGE 1 WASHABLE PARTICLE PRE-FILTER
The stage 1 particle
Fig. 9 |
Fig.10
OPTIONAL: Changing the Odor Control Filter
If you have chosen to use the CZ odor control filter that came with your air purifier, it will lose its effectiveness over time and will need to be replaced. Call
If using the CZ odor control filter, it is recommended that you store the original washable
To insert it into the unit, simply place securely into the rear grille in lieu of standard
Note: The CZ filter is not washable.
REPLACING THE ULTRAVIOLET (UV) BULBS
•After about six months of continuous use, the UV bulbs must be replaced.
•When it is time to replace the bulbs, the UV Bulb indicator light (Fig. 11) will change from green to red and the display will show this message.
•To replace the bulb cartridge take the following steps:
Fig. 11 |
Fig. 12
°Be sure to turn off and unplug your air purifier.
°Remove the rear grille and the upper HEPA Type filter (Fig. 12).
°Remove the UV bulb by pulling it from the unit (Fig. 13). Dispose old UV Bulb cartridge only at household hazardous waste collection sites.
°Insert a new UV bulb
Fig. 13
°Replace the HEPA Type filter and rear grille.
°Plug the air purifier back into an electrical socket and turn the air purifier on.
°Press and hold the UV Bulb button for 5 seconds or until the light turns from red to green and the UV bulb related message in the display is cleared (Fig. 14) .
Fig. 14 |
•Notes: Bulb cartridge is not intended for use with any other product or
purpose. This unit is equipped with a safety interlock switch. The unit will not operate while the rear grille is removed.