Sanyo VCC-6974 RS-485 terminal connections, Connection to a VCR, Connection to a multiplexer

Page 12

CONNECTIONS

CAMERA IN terminal

 

 

 

 

ALARM input

 

 

 

 

 

 

 

G

RS485

 

 

 

 

 

 

 

 

 

 

 

A

control

 

 

 

 

 

 

terminal

 

 

 

 

 

 

 

B

terminal

 

 

 

 

 

 

 

 

ALARM IN

 

 

 

 

 

 

 

 

 

9

10

11

12

13

14

15

16

C 1

2

3

4

5

6

7

8

9 10 11 12 13 1415 16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSOR ALARM

 

 

C A B C AL C R1 R2 C SW C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VCR

 

MONITOR

RS485

 

 

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL

 

 

 

 

 

 

 

 

1

2

 

 

 

 

 

 

 

 

 

IN

OUT

A

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multiplexer

 

 

 

 

 

 

 

 

 

Monitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER

 

 

 

 

 

RS485

GND

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

B

 

 

 

 

 

 

 

 

12V DC IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

System controller

Timelapse VCR

Before making any connection, make sure all the peripheral devices are turned off.

Multiple units are connected in series using twisted-pair cables (bridge connection). To set the addresses and make other fine adjustments, please refer to page 57.

RS-485 terminal connections

Connect a shielded twisted-pair cable (AWG22) from signal A to signal A, and from signal B to signal B of the RS485 control terminal of each of the devices.

Connection to a VCR

Make the connection between the RS485 (A, B, G) terminal on this unit and the VCR RS485 A and B terminals and the C terminal.

Connection to a multiplexer

Make the connection between the RS485 (A, B, G) terminal on this unit and the multiplexer control terminals (A, B, C).

G B A

 

Shielded twisted-pair cable

Push in to insert cable

To A signal

 

To B signal

 

Ground

English 11

Image 12
Contents About this manual Propos de ce manuelContents FeaturesInformation to User For the customers in CanadaPour la clientèle canadienne Precautions Power indicator Power Video output connector Video OUT BNC typeAlarm output terminal ALARM, C, a Parts NamesCamera setup section under the cover Lens iris output connector LensMenu setting button SET Cursor button CursorLens mount cap If using a Video type auto-iris lens Concerning AUTO-IRIS LensesDC type auto-iris lens Video type auto-iris lensMounting the Lens Remove the lens mount cap from the cameraMount type lens Rewiring the lens cable in the lens iris plug Flange-back adjustmentConnections Basic connection for monitoring or recordingCoaxial cable type and maximum length RS-485 terminal connections Connection to a VCRConnection to a multiplexer About the Alarm output terminal Remote controller circuit connectionsPreset will return to the zoom pan, tilt center position Using the Menu Screen Using the Cursor buttonSwitching to sub-menu screens Switching to the Main Menu screenUsing the Menu Screen Language setting Then press the SET buttonCamera ID setting Example To set the camera ID to BN1Determining the start position for character input Changing the camera ID to a new IDDisplay will return to the Camera ID Setting screen Sync settings Internal synchronization INTExternal sync VBS Power supply synchronization setting L L External sync setting VBS Menu Back END Iris setting AI Auto Iris mode settingLens Type setting Adjust the Iris Level setting DC type lens only BLC settingAI/BLCMULTI BLC/EVAL 5-section photometry mode setting BLC Window Weighting screen will be displayedWeighting Returning the values to the default settingsSense UP setting EI Electronic Iris mode settingPress the Cursor l, then d or c button until EI White Balance setting Automatic color temperature tracking setting ATWManual white balance MWB Masking setting White BALANCE/ATWMASKINGMenu Back END Push-lock white balance adjustment AWC Press and hold the SET buttonManual white balance setting MWB Electronic Shutter setting Short mode ShortLong exposure mode Long For Short mode For Long mode When Motion is set to ON, Long mode cannot be selectedMotion setting Iris Sense UP mode has been set. Refer toExample Size setting function Size Mask area setting function MaskingSensitivity setting function Sensitivity Alarm interval setting function IntervalDirection setting Üü, íí, óó, ññSize setting V vertical value is flashing, then press the Cursor c buttonMotion Size display table Returning to the default setting MOTION/MASKING Menu Back END Sensitivity setting This sets the movement amplitude of subjects on the screenMaximum Zoom setting MOTION/ZOOM, IntervalInterval setting Alarm Sign settingImage is zoomed in when a movement is detected Camera ID flashes on-screen when a movement is detectedChecking the detected movements set by the Motion item Active Move Differ Option settings Aperture setting AGC setting Gamma settingFor FIX mode PanningReturning to the default settings OPTION/FIXI TiltFor VAR mode ZoomingOPTION/VAR ZOOM, Tilt Mirror setting RS-485 settingAddress setting Terminate settingAbout SW No Initial setting SET buttonOperations Using the System Controller Operations using the camera Menu screensOperations using the camera command Camera button Electronic zoomIris level operations Setting the Sense UP and electronic shutter Backlight correction settingsWhite balance and AWC-LOCK settings Menu Display 4321Menu Display Troubleshooting No picture on the monitor screenPicture is not clear Specifications CameraAccessories Dimensions mmExclusions