MOTION/ZOOM, INTERVAL

DURATION

This sets how long the moving subject should be on the screen before it is detected. A lower setting will set a longer on screen duration before the subject is detected.

Press the CURSOR (l, then d or c) button so that the DURATION value is flashing. (Maximum: 60)

Set the value to a large if objects which are moving fast are not to be detected.

Each setting step represents 1/12 of a second. The maximum on-screen duration that can be set is 5 seconds (1/12 x 60).

Returning to the default setting

Press the CURSOR (l, then d or c) button to change the PRESET setting to ON, then press the SET button.

Note: If all the settings values are too large, alarm triggering may not operate as desired.

When finished:

Press the CURSOR (l) button to select BACK (it will flash) at the bottom of the screen. Then press the CURSOR (d or c) button to change BACK to END, and press the SET button.

To return to the previous screen, select BACK then press the SET button.

EZOOM setting

Press the CURSOR (j, then d or c) button to select the ZOOM setting OFF (the setting will flash), then press the CURSOR button repeatedly.

The length of time for zoom display will be displayed. When a doubtful movement is detected, the moving object is followed at a zoom ratio of X2.

Note: The higher the SENSITIVITY screen DURATION item setting is, the longer it will take for the movement to be tracked. To track all movements set the DURATION to 1.

CURSOR

SET

 

 

 

 

 

MENU

BACK

 

 

 

ADJUSTMENT FOR MOTION

 

 

 

DIRECTION

OFF

 

 

 

SIZE

SET

p

 

 

MASKING

OFF

 

CURSOR

SENSITIVITY

SET

p

ZOOM

OFF

 

OFF5S10S20S30S60S

44 English

Image 45
Contents Propos de ce manuel About this manualFeatures ContentsInformation to User For the customers in CanadaPour la clientèle canadienne Precautions Video output connector Video OUT BNC type Power indicator PowerAlarm output terminal ALARM, C, a Parts NamesLens iris output connector Lens Camera setup section under the coverMenu setting button SET Cursor button CursorLens mount cap Concerning AUTO-IRIS Lenses If using a Video type auto-iris lensDC type auto-iris lens Video type auto-iris lensMounting the Lens Remove the lens mount cap from the cameraMount type lens Flange-back adjustment Rewiring the lens cable in the lens iris plugConnections Basic connection for monitoring or recordingCoaxial cable type and maximum length RS-485 terminal connections Connection to a VCRConnection to a multiplexer About the Alarm output terminal Remote controller circuit connectionsPreset will return to the zoom pan, tilt center position Using the Cursor button Using the Menu ScreenSwitching to sub-menu screens Switching to the Main Menu screenUsing the Menu Screen Then press the SET button Language settingExample To set the camera ID to BN1 Camera ID settingDetermining the start position for character input Changing the camera ID to a new IDDisplay will return to the Camera ID Setting screen Sync settings Internal synchronization INTExternal sync VBS Power supply synchronization setting L L External sync setting VBS Menu Back END Iris setting AI Auto Iris mode settingLens Type setting BLC setting Adjust the Iris Level setting DC type lens onlyAI/BLCMULTI BLC Window Weighting screen will be displayed BLC/EVAL 5-section photometry mode settingReturning the values to the default settings WeightingSense UP setting EI Electronic Iris mode settingPress the Cursor l, then d or c button until EI White Balance setting Automatic color temperature tracking setting ATWManual white balance MWB White BALANCE/ATWMASKING Masking settingMenu Back END Press and hold the SET button Push-lock white balance adjustment AWCManual white balance setting MWB Electronic Shutter setting Short mode ShortLong exposure mode Long For Short mode When Motion is set to ON, Long mode cannot be selected For Long modeMotion setting Iris Sense UP mode has been set. Refer toExample Mask area setting function Masking Size setting function SizeSensitivity setting function Sensitivity Alarm interval setting function IntervalÜü, íí, óó, ññ Direction settingV vertical value is flashing, then press the Cursor c button Size settingMotion Size display table Returning to the default setting MOTION/MASKING Menu Back END Sensitivity setting This sets the movement amplitude of subjects on the screenMaximum MOTION/ZOOM, Interval Zoom settingAlarm Sign setting Interval settingImage is zoomed in when a movement is detected Camera ID flashes on-screen when a movement is detectedChecking the detected movements set by the Motion item Active Move Differ Option settings Aperture setting Gamma setting AGC settingPanning For FIX modeOPTION/FIXI Tilt Returning to the default settingsZooming For VAR modeOPTION/VAR ZOOM, Tilt RS-485 setting Mirror settingAddress setting Terminate settingAbout SW No SET button Initial settingOperations using the camera Menu screens Operations Using the System ControllerOperations using the camera command Camera button Electronic zoomIris level operations Setting the Sense UP and electronic shutter Backlight correction settingsWhite balance and AWC-LOCK settings 4321 Menu DisplayMenu Display Troubleshooting No picture on the monitor screenPicture is not clear Camera SpecificationsDimensions mm AccessoriesExclusions