Sanyo VCC-6974 instruction manual Adjust the Iris Level setting DC type lens only, BLC setting

Page 24

USING THE MENU SCREEN

AI/BLC•IRIS LEVEL

Adjust the IRIS LEVEL setting (DC type lens only)

Press the CURSOR (l) button so that the IRIS LEVEL value is flashing, then press the CURSOR (d or c) button to adjust the IRIS LEVEL setting.

The larger the value, the greater the iris level.

Returning the value to the default setting

Press the CURSOR (l, then d or c) button to change the PRESET setting to ON, then press the SET button.

When finished:

Press the CURSOR (l) button to select BACK (it will flash) at the bottom of the screen. Then press the CURSOR (d or c) button to change BACK to END, and press the SET button.

To return to the previous screen, select BACK then press the SET button.

BLC setting

The following two types of BLC adjustment can be carried out

MULTI (multi-spot photometry):

Brighter sections of the background are masked so that they do not affect photometry detection. Brighter sections of the background are determined on-screen, and they are masked so that they are in a position which do not affect the main subject (such as a person).

Note: If using a VIDEO type lens, the MULTI mode setting cannot be used.

EVAL (5-section photometry):

Photometry and backlight correction are carried out so that the optimum image can be obtained, even if the subject’s background is too bright.

CURSOR

CURSOR SET

ADJUSTMENT FOR AI

LENS TYPE

DC

 

BLC

OFF

SENSE UP

OFF

[IRIS LEVEL]

 

 

í--ú---z------ü

30

MENU

BACK

MENU

END

ADJUSTMENT FOR AI

LENS TYPE

VIDEO

BLC

EVAL p

OFF

English 23

Image 24
Contents About this manual Propos de ce manuelContents FeaturesInformation to User For the customers in CanadaPour la clientèle canadienne Precautions Power indicator Power Video output connector Video OUT BNC typeAlarm output terminal ALARM, C, a Parts NamesCamera setup section under the cover Lens iris output connector LensMenu setting button SET Cursor button CursorLens mount cap If using a Video type auto-iris lens Concerning AUTO-IRIS LensesDC type auto-iris lens Video type auto-iris lensMounting the Lens Remove the lens mount cap from the cameraMount type lens Rewiring the lens cable in the lens iris plug Flange-back adjustmentConnections Basic connection for monitoring or recordingCoaxial cable type and maximum length RS-485 terminal connections Connection to a VCRConnection to a multiplexer About the Alarm output terminal Remote controller circuit connectionsPreset will return to the zoom pan, tilt center position Using the Menu Screen Using the Cursor buttonSwitching to sub-menu screens Switching to the Main Menu screenUsing the Menu Screen Language setting Then press the SET buttonCamera ID setting Example To set the camera ID to BN1Determining the start position for character input Changing the camera ID to a new IDDisplay will return to the Camera ID Setting screen Sync settings Internal synchronization INTExternal sync VBS Power supply synchronization setting L L External sync setting VBS Menu Back END Iris setting AI Auto Iris mode settingLens Type setting Adjust the Iris Level setting DC type lens only BLC settingAI/BLCMULTI BLC/EVAL 5-section photometry mode setting BLC Window Weighting screen will be displayedWeighting Returning the values to the default settingsSense UP setting EI Electronic Iris mode settingPress the Cursor l, then d or c button until EI White Balance setting Automatic color temperature tracking setting ATWManual white balance MWB Masking setting White BALANCE/ATWMASKINGMenu Back END Push-lock white balance adjustment AWC Press and hold the SET buttonManual white balance setting MWB Electronic Shutter setting Short mode ShortLong exposure mode Long For Short mode For Long mode When Motion is set to ON, Long mode cannot be selectedMotion setting Iris Sense UP mode has been set. Refer toExample Size setting function Size Mask area setting function MaskingSensitivity setting function Sensitivity Alarm interval setting function IntervalDirection setting Üü, íí, óó, ññSize setting V vertical value is flashing, then press the Cursor c buttonMotion Size display table Returning to the default setting MOTION/MASKING Menu Back END Sensitivity setting This sets the movement amplitude of subjects on the screenMaximum Zoom setting MOTION/ZOOM, IntervalInterval setting Alarm Sign settingImage is zoomed in when a movement is detected Camera ID flashes on-screen when a movement is detectedChecking the detected movements set by the Motion item Active Move Differ Option settings Aperture setting AGC setting Gamma settingFor FIX mode PanningReturning to the default settings OPTION/FIXI TiltFor VAR mode ZoomingOPTION/VAR ZOOM, Tilt Mirror setting RS-485 settingAddress setting Terminate settingAbout SW No Initial setting SET buttonOperations Using the System Controller Operations using the camera Menu screensOperations using the camera command Camera button Electronic zoomIris level operations Setting the Sense UP and electronic shutter Backlight correction settingsWhite balance and AWC-LOCK settings Menu Display 4321Menu Display Troubleshooting No picture on the monitor screenPicture is not clear Specifications CameraAccessories Dimensions mmExclusions