Sanyo VCC-6974 Concerning AUTO-IRIS Lenses, DC type auto-iris lens, Video type auto-iris lens

Page 8

CONCERNING AUTO-IRIS LENSES

A.I.

LENS

DC VIDEO

DC type auto-iris lens

A lens without amplifier circuit that operates only on a DC power source. In general, this type of lens is referred to as DC type coil lens or DC type non-amplifier lens.

(Set the A.I. LENS switch to the DC position.)

VIDEO type auto-iris lens

A lens with amplifier circuit that operates on video signal and DC power source. In general, this type of lens is referred to as EE amplifier type lens.

ALC and LEVEL volume level controls are available on the lens for iris adjustments.

(Set the A.I. LENS switch to the VIDEO position.)

Compatible auto-iris lenses

1/3 inch Sanyo DC type lens

VIDEO type lens

VCL-CS8LY: Standard angle, f= 8 mm

Standard angle, f= 9 mm

VCL-CS4LY: Wide angle, f= 4 mm

Telephoto angle, f= 12 mm

 

 

VCL-CS2LY: Ultra-wide angle, f= 2.8 mm

Greater telephoto angle, f= 16 mm

 

 

If using a VIDEO type auto-iris lens

Set the ALC and LEVEL controls on the lens to adjust the iris. Normally the ALC volume should be turned all the way to Av (Average).

Depending on the type of lens used, the lens may not perform properly. In such a case, adjust the LEVEL volume on the lens casing to correct.

English 7

Image 8
Contents About this manual Propos de ce manuelContents FeaturesPour la clientèle canadienne Information to UserFor the customers in Canada Precautions Power indicator Power Video output connector Video OUT BNC type Alarm output terminal ALARM, C, a Parts NamesCamera setup section under the cover Lens iris output connector LensMenu setting button SET Cursor button CursorLens mount cap If using a Video type auto-iris lens Concerning AUTO-IRIS LensesDC type auto-iris lens Video type auto-iris lensMount type lens Mounting the LensRemove the lens mount cap from the camera Rewiring the lens cable in the lens iris plug Flange-back adjustmentCoaxial cable type and maximum length ConnectionsBasic connection for monitoring or recording Connection to a multiplexer RS-485 terminal connectionsConnection to a VCR Preset will return to the zoom pan, tilt center position About the Alarm output terminalRemote controller circuit connections Using the Menu Screen Using the Cursor buttonSwitching to sub-menu screens Switching to the Main Menu screenUsing the Menu Screen Language setting Then press the SET buttonCamera ID setting Example To set the camera ID to BN1Determining the start position for character input Changing the camera ID to a new IDDisplay will return to the Camera ID Setting screen External sync VBS Sync settingsInternal synchronization INT Power supply synchronization setting L L External sync setting VBS Menu Back END Lens Type setting Iris settingAI Auto Iris mode setting Adjust the Iris Level setting DC type lens only BLC settingAI/BLCMULTI BLC/EVAL 5-section photometry mode setting BLC Window Weighting screen will be displayedWeighting Returning the values to the default settingsPress the Cursor l, then d or c button until EI Sense UP settingEI Electronic Iris mode setting Manual white balance MWB White Balance settingAutomatic color temperature tracking setting ATW Masking setting White BALANCE/ATWMASKINGMenu Back END Push-lock white balance adjustment AWC Press and hold the SET buttonManual white balance setting MWB Long exposure mode Long Electronic Shutter settingShort mode Short For Short mode For Long mode When Motion is set to ON, Long mode cannot be selectedExample Motion settingIris Sense UP mode has been set. Refer to Size setting function Size Mask area setting function MaskingSensitivity setting function Sensitivity Alarm interval setting function IntervalDirection setting Üü, íí, óó, ññSize setting V vertical value is flashing, then press the Cursor c buttonMotion Size display table Returning to the default setting MOTION/MASKING Menu Back END Maximum Sensitivity settingThis sets the movement amplitude of subjects on the screen Zoom setting MOTION/ZOOM, IntervalInterval setting Alarm Sign settingChecking the detected movements set by the Motion item Image is zoomed in when a movement is detectedCamera ID flashes on-screen when a movement is detected Active Move Differ Option settings Aperture setting AGC setting Gamma settingFor FIX mode PanningReturning to the default settings OPTION/FIXI TiltFor VAR mode ZoomingOPTION/VAR ZOOM, Tilt Mirror setting RS-485 settingAbout SW No Address settingTerminate setting Initial setting SET buttonOperations Using the System Controller Operations using the camera Menu screensIris level operations Operations using the camera command Camera buttonElectronic zoom White balance and AWC-LOCK settings Setting the Sense UP and electronic shutterBacklight correction settings Menu Display 4321Menu Display Picture is not clear TroubleshootingNo picture on the monitor screen Specifications CameraAccessories Dimensions mmExclusions