USING THE MENU SCREEN

Notes concerning the menu settings

Modes that cannot be used together

A)The IRIS item SENSE UP setting (other than OFF) and the MOTION item ON setting.

B)The SHUTTER item LONG setting and the MOTION item ON setting.

(X)

(X)

ADJUSTMENT FOR AI

 

MAIN MENU

LENS TYPE

DC

 

LANGUAGE

BLC

OFF

 

CAMERA ID

SENSE UP

X2

 

SYNC

 

 

 

IRIS

 

 

 

WHITE BALANCE

 

 

 

SHUTTER

 

 

 

MOTION

 

 

MAIN MENU

SET

p

LANGUAGE

OFF

 

CAMERA ID

INT

 

SYNC

AI

p

IRIS

ATW

p

WHITE BALANCE

OFF

 

SHUTTER

ON

 

 

 

 

 

MAIN MENU

SET

p

 

LANGUAGE

OFF

 

 

CAMERA ID

INT

 

 

SYNC

AI

p

 

IRIS

ATW

p

 

WHITE BALANCE

LONG

 

 

SHUTTER

 

 

 

MOTION

SET p

OFF

INT AI p ATW p

OFF

ON

When the IRIS item SENSE UP is used (setting other than OFF), the SHUTTER SPEED cannot be set. (Set either one to OFF in order to use the other one.)

If the SHUTTER item is set to LONG or SHORT and the IRIS AI or EI mode SENSE UP setting is used (setting other than OFF), the SHUTTER item setting will be forced to OFF.

The SHUTTER SPEED cannot be set if the IRIS item is set to EI mode. Switch the IRIS item setting to AI mode.

When the OPTION MENU screen ZOOM or MIRROR items are being used, the following items setting screens will not be zoomed in or mirrored.

The BLC setting screen

The ADJUSTMENT FOR MOTION screen SIZE and MASKING setting screens

The WHITE BALANCE item ATW MASKING screen

If the OPTION MENU screen AGC item is set to OFF and the IRIS mode SENSE UP setting is used (setting other than OFF), the AGC item setting will be forced to ON.

14 English

Image 15
Contents Propos de ce manuel About this manualFeatures ContentsInformation to User For the customers in CanadaPour la clientèle canadienne Precautions Parts Names Power indicator PowerVideo output connector Video OUT BNC type Alarm output terminal ALARM, C, aCursor button Cursor Camera setup section under the coverLens iris output connector Lens Menu setting button SETLens mount cap Video type auto-iris lens If using a Video type auto-iris lensConcerning AUTO-IRIS Lenses DC type auto-iris lensMounting the Lens Remove the lens mount cap from the cameraMount type lens Flange-back adjustment Rewiring the lens cable in the lens iris plugConnections Basic connection for monitoring or recordingCoaxial cable type and maximum length RS-485 terminal connections Connection to a VCRConnection to a multiplexer About the Alarm output terminal Remote controller circuit connectionsPreset will return to the zoom pan, tilt center position Switching to the Main Menu screen Using the Menu ScreenUsing the Cursor button Switching to sub-menu screensUsing the Menu Screen Then press the SET button Language settingChanging the camera ID to a new ID Camera ID settingExample To set the camera ID to BN1 Determining the start position for character inputDisplay will return to the Camera ID Setting screen Sync settings Internal synchronization INTExternal sync VBS Power supply synchronization setting L L External sync setting VBS Menu Back END Iris setting AI Auto Iris mode settingLens Type setting BLC setting Adjust the Iris Level setting DC type lens onlyAI/BLCMULTI BLC Window Weighting screen will be displayed BLC/EVAL 5-section photometry mode settingReturning the values to the default settings WeightingSense UP setting EI Electronic Iris mode settingPress the Cursor l, then d or c button until EI White Balance setting Automatic color temperature tracking setting ATWManual white balance MWB White BALANCE/ATWMASKING Masking settingMenu Back END Press and hold the SET button Push-lock white balance adjustment AWCManual white balance setting MWB Electronic Shutter setting Short mode ShortLong exposure mode Long For Short mode When Motion is set to ON, Long mode cannot be selected For Long modeMotion setting Iris Sense UP mode has been set. Refer toExample Alarm interval setting function Interval Size setting function SizeMask area setting function Masking Sensitivity setting function SensitivityÜü, íí, óó, ññ Direction settingV vertical value is flashing, then press the Cursor c button Size settingMotion Size display table Returning to the default setting MOTION/MASKING Menu Back END Sensitivity setting This sets the movement amplitude of subjects on the screenMaximum MOTION/ZOOM, Interval Zoom settingAlarm Sign setting Interval settingImage is zoomed in when a movement is detected Camera ID flashes on-screen when a movement is detectedChecking the detected movements set by the Motion item Active Move Differ Option settings Aperture setting Gamma setting AGC settingPanning For FIX modeOPTION/FIXI Tilt Returning to the default settingsZooming For VAR modeOPTION/VAR ZOOM, Tilt RS-485 setting Mirror settingAddress setting Terminate settingAbout SW No SET button Initial settingOperations using the camera Menu screens Operations Using the System ControllerOperations using the camera command Camera button Electronic zoomIris level operations Setting the Sense UP and electronic shutter Backlight correction settingsWhite balance and AWC-LOCK settings 4321 Menu DisplayMenu Display Troubleshooting No picture on the monitor screenPicture is not clear Camera SpecificationsDimensions mm AccessoriesExclusions