Sanyo VCC-6974 Motion setting, Iris Sense UP mode has been set. Refer to, Example

Page 37

USING THE MENU SCREEN

MOTION

MOTION setting

For the MOTION setting, the screen area is split up into 64 (8 X 8) detection areas where movements (or changes) are detected.

Then, using the SENSITIVITY and other menu settings, these movements can be set to trigger alarms. With these menu settings, you can set the MOTION setting to detect only the motions you require for your situation.

Though, the initial settings will provide adequate detection of movement, alarms may be triggered by motions that are normal and should be ignored. To customize the MOTION setting for your

 

MAIN MENU

 

 

CURSOR SET

LANGUAGE

SET

p

 

CAMERA ID

OFF

 

 

SYNC

INT

 

 

IRIS

AI

p

 

WHITE BALANCE

ATW

p

 

SHUTTER

OFF

 

 

MOTION

OFF

 

 

 

ON

p

situation, use the MASKING, SENSITIVITY, and other menu settings.

For more details regarding the MOTION operation, refer to the examples given on page 46.

Note: MOTION settings are not possible if either of the following settings have been made:

The IRIS (SENSE UP) mode has been set. (Refer to page 27.)

The SHUTTER (LONG) mode has been set. (Refer to page 35.)

Note:

(Example)

The detection is done according to the movement and changes sensed in these areas.

When the MOTION default setting is OFF, movements will not be detected and alarms triggers will not be output.

When doing the MOTION settings, the dotted lines and the mask shown on the illustrations are for clarity only, they do not actually appear on-screen.

An alarm is output when all the parameters set for ADJUSTMENT FOR MOTION items are met.

No movement sensed on-

A moving subject is

screen.

detected.

36 English

Image 37
Contents Propos de ce manuel About this manualFeatures ContentsFor the customers in Canada Information to UserPour la clientèle canadienne Precautions Video output connector Video OUT BNC type Power indicator PowerAlarm output terminal ALARM, C, a Parts NamesLens iris output connector Lens Camera setup section under the coverMenu setting button SET Cursor button CursorLens mount cap Concerning AUTO-IRIS Lenses If using a Video type auto-iris lensDC type auto-iris lens Video type auto-iris lensRemove the lens mount cap from the camera Mounting the LensMount type lens Flange-back adjustment Rewiring the lens cable in the lens iris plugBasic connection for monitoring or recording ConnectionsCoaxial cable type and maximum length Connection to a VCR RS-485 terminal connectionsConnection to a multiplexer Remote controller circuit connections About the Alarm output terminalPreset will return to the zoom pan, tilt center position Using the Cursor button Using the Menu ScreenSwitching to sub-menu screens Switching to the Main Menu screenUsing the Menu Screen Then press the SET button Language settingExample To set the camera ID to BN1 Camera ID settingDetermining the start position for character input Changing the camera ID to a new IDDisplay will return to the Camera ID Setting screen Internal synchronization INT Sync settingsExternal sync VBS Power supply synchronization setting L L External sync setting VBS Menu Back END AI Auto Iris mode setting Iris settingLens Type setting BLC setting Adjust the Iris Level setting DC type lens onlyAI/BLCMULTI BLC Window Weighting screen will be displayed BLC/EVAL 5-section photometry mode settingReturning the values to the default settings WeightingEI Electronic Iris mode setting Sense UP settingPress the Cursor l, then d or c button until EI Automatic color temperature tracking setting ATW White Balance settingManual white balance MWB White BALANCE/ATWMASKING Masking settingMenu Back END Press and hold the SET button Push-lock white balance adjustment AWCManual white balance setting MWB Short mode Short Electronic Shutter setting Long exposure mode Long For Short mode When Motion is set to ON, Long mode cannot be selected For Long modeIris Sense UP mode has been set. Refer to Motion settingExample Mask area setting function Masking Size setting function SizeSensitivity setting function Sensitivity Alarm interval setting function IntervalÜü, íí, óó, ññ Direction settingV vertical value is flashing, then press the Cursor c button Size settingMotion Size display table Returning to the default setting MOTION/MASKING Menu Back END This sets the movement amplitude of subjects on the screen Sensitivity settingMaximum MOTION/ZOOM, Interval Zoom settingAlarm Sign setting Interval settingCamera ID flashes on-screen when a movement is detected Image is zoomed in when a movement is detectedChecking the detected movements set by the Motion item Active Move Differ Option settings Aperture setting Gamma setting AGC settingPanning For FIX modeOPTION/FIXI Tilt Returning to the default settingsZooming For VAR modeOPTION/VAR ZOOM, Tilt RS-485 setting Mirror settingTerminate setting Address settingAbout SW No SET button Initial settingOperations using the camera Menu screens Operations Using the System ControllerElectronic zoom Operations using the camera command Camera buttonIris level operations Backlight correction settings Setting the Sense UP and electronic shutterWhite balance and AWC-LOCK settings 4321 Menu DisplayMenu Display No picture on the monitor screen TroubleshootingPicture is not clear Camera SpecificationsDimensions mm AccessoriesExclusions