Sanyo VCC-6974 instruction manual Interval setting, Alarm Sign setting

Page 46

USING THE MENU SCREEN

MOTION/INTERVAL, ALARM SIGN

FINTERVAL setting

Press the CURSOR (l) button so that the INTERVAL value is flashing, then press the CURSOR (d or c) button repeatedly.

After an alarm signal has been output once, this sets the length of time that no further alarm signal is output when movement is detected.

GALARM SIGN setting

Press the CURSOR (l, then d or c) button to change the ALARM SIGN setting to “ON” or “OFF”.

OFF: No alarm display appears

ON: The camera ID flashes when movement is detected.

Note: If the camera ID display is not turned on, the camera ID which has been set in the CAMERA ID SETTING screen will flash. The length of time that the camera ID flashes is the same as the length of time for the alarm ignore time (INTERVAL) setting.

When finished

Press the CURSOR (l) button to select BACK (it will flash) at the bottom of the screen. Then press the CURSOR (d or c) button to change BACK to END, and press the SET button.

To return to the previous screen, select BACK then press the SET button.

Returning to the default setting

Press the CURSOR (l, then d or c) button to change the PRESET setting to ON, then press the SET button.

 

 

 

 

 

 

ADJUSTMENT FOR MOTION

 

 

 

 

 

 

 

DIRECTION

 

 

OFF

 

 

 

 

 

 

 

SIZE

 

 

 

SET

p

 

 

 

 

 

 

MASKING

 

 

OFF

 

 

CURSOR

SENSITIVITY

 

SET

p

 

ZOOM

 

 

 

OFF

p

 

 

 

 

 

 

INTERVAL

 

 

5S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5S10S15S20S30S

 

 

 

 

 

 

 

5M

4M

3M

2M

 

1M

 

 

 

 

 

 

 

ADJUSTMENT FOR MOTION

 

 

 

 

 

 

DIRECTION

 

 

OFF

 

 

 

 

 

 

 

SIZE

 

 

 

SET p

 

 

 

 

 

 

MASKING

 

 

OFF

 

 

CURSOR

SENSITIVITY

 

SET p

 

ZOOM

 

 

 

OFF p

 

 

 

 

 

 

INTERVAL

 

 

5S

 

 

 

 

 

 

 

ALARM SIGN

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

????????

 

CURSOR

SET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENU

 

 

 

BACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENU

 

 

 

END

 

 

 

 

 

 

 

 

 

 

 

English 45

Image 46
Contents About this manual Propos de ce manuelContents FeaturesFor the customers in Canada Information to UserPour la clientèle canadienne Precautions Alarm output terminal ALARM, C, a Power indicator PowerVideo output connector Video OUT BNC type Parts NamesMenu setting button SET Camera setup section under the coverLens iris output connector Lens Cursor button CursorLens mount cap DC type auto-iris lens If using a Video type auto-iris lensConcerning AUTO-IRIS Lenses Video type auto-iris lensRemove the lens mount cap from the camera Mounting the LensMount type lens Rewiring the lens cable in the lens iris plug Flange-back adjustmentBasic connection for monitoring or recording ConnectionsCoaxial cable type and maximum length Connection to a VCR RS-485 terminal connectionsConnection to a multiplexer Remote controller circuit connections About the Alarm output terminalPreset will return to the zoom pan, tilt center position Switching to sub-menu screens Using the Menu ScreenUsing the Cursor button Switching to the Main Menu screenUsing the Menu Screen Language setting Then press the SET buttonDetermining the start position for character input Camera ID settingExample To set the camera ID to BN1 Changing the camera ID to a new IDDisplay will return to the Camera ID Setting screen Internal synchronization INT Sync settingsExternal sync VBS Power supply synchronization setting L L External sync setting VBS Menu Back END AI Auto Iris mode setting Iris settingLens Type setting Adjust the Iris Level setting DC type lens only BLC settingAI/BLCMULTI BLC/EVAL 5-section photometry mode setting BLC Window Weighting screen will be displayedWeighting Returning the values to the default settingsEI Electronic Iris mode setting Sense UP settingPress the Cursor l, then d or c button until EI Automatic color temperature tracking setting ATW White Balance settingManual white balance MWB Masking setting White BALANCE/ATWMASKINGMenu Back END Push-lock white balance adjustment AWC Press and hold the SET buttonManual white balance setting MWB Short mode Short Electronic Shutter settingLong exposure mode Long For Short mode For Long mode When Motion is set to ON, Long mode cannot be selectedIris Sense UP mode has been set. Refer to Motion settingExample Sensitivity setting function Sensitivity Size setting function SizeMask area setting function Masking Alarm interval setting function IntervalDirection setting Üü, íí, óó, ññSize setting V vertical value is flashing, then press the Cursor c buttonMotion Size display table Returning to the default setting MOTION/MASKING Menu Back END This sets the movement amplitude of subjects on the screen Sensitivity settingMaximum Zoom setting MOTION/ZOOM, IntervalInterval setting Alarm Sign settingCamera ID flashes on-screen when a movement is detected Image is zoomed in when a movement is detectedChecking the detected movements set by the Motion item Active Move Differ Option settings Aperture setting AGC setting Gamma settingFor FIX mode PanningReturning to the default settings OPTION/FIXI TiltFor VAR mode ZoomingOPTION/VAR ZOOM, Tilt Mirror setting RS-485 settingTerminate setting Address settingAbout SW No Initial setting SET buttonOperations Using the System Controller Operations using the camera Menu screensElectronic zoom Operations using the camera command Camera buttonIris level operations Backlight correction settings Setting the Sense UP and electronic shutterWhite balance and AWC-LOCK settings Menu Display 4321Menu Display No picture on the monitor screen TroubleshootingPicture is not clear Specifications CameraAccessories Dimensions mmExclusions