Sanyo VCC-6974 About the Alarm output terminal, Remote controller circuit connections

Page 13

CONNECTIONS

About the Alarm output terminal

Connect this unit to a VCR or a multiplexer. Alarm output

A: Alarm signal output

C: Common

Alarm active

5 V

About 500 msec.

CR

1.1k

SW 1 : Electric PTZ

*

(pan-tilt-zoom) preset

0.68k

CAUTION:

The digital processing of the settings may disturb the image for a few seconds after the camera is turned on.

While the menus are being set, noise sent on the lines by peripheral devices may cause the settings to change. In such a case, turn the power off then on again.

Remote controller circuit connections

Use the layout above to make a remote controller and make the connections to the remote input pins (C, R) of the REMOTE terminal as indicated. This will permit remote controlled operation of this unit. (make contact LOW input)

Note:

The maximum length of cable for remote controlled operation is

 

6 m (AWG 24).

If the ZOOM item in the OPTION MENU is set to ON, remote

 

controlled zoom is possible even while the menu screens are

SW: switch

SW 2 : Electric PTZ (pan-tilt-zoom) OFF

0.91k

SW 3 : Zoom (wide)

1.2k

SW 4 : Zoom (tele)

1.8k

SW 5 : Panning (left)

2.7k

SW 6 : Panning (right)

3.9k

SW 7 : Tilting (upward)

9.1k

SW 8 : Tilting (down)

displayed.

*Preset: will return to the zoom (pan, tilt) center position.

12 English

Image 13
Contents Propos de ce manuel About this manualFeatures ContentsFor the customers in Canada Information to UserPour la clientèle canadienne Precautions Video output connector Video OUT BNC type Power indicator PowerAlarm output terminal ALARM, C, a Parts NamesLens iris output connector Lens Camera setup section under the coverMenu setting button SET Cursor button CursorLens mount cap Concerning AUTO-IRIS Lenses If using a Video type auto-iris lensDC type auto-iris lens Video type auto-iris lensRemove the lens mount cap from the camera Mounting the LensMount type lens Flange-back adjustment Rewiring the lens cable in the lens iris plugBasic connection for monitoring or recording ConnectionsCoaxial cable type and maximum length Connection to a VCR RS-485 terminal connectionsConnection to a multiplexer Remote controller circuit connections About the Alarm output terminalPreset will return to the zoom pan, tilt center position Using the Cursor button Using the Menu ScreenSwitching to sub-menu screens Switching to the Main Menu screenUsing the Menu Screen Then press the SET button Language settingExample To set the camera ID to BN1 Camera ID settingDetermining the start position for character input Changing the camera ID to a new IDDisplay will return to the Camera ID Setting screen Internal synchronization INT Sync settingsExternal sync VBS Power supply synchronization setting L L External sync setting VBS Menu Back END AI Auto Iris mode setting Iris settingLens Type setting BLC setting Adjust the Iris Level setting DC type lens onlyAI/BLCMULTI BLC Window Weighting screen will be displayed BLC/EVAL 5-section photometry mode settingReturning the values to the default settings WeightingEI Electronic Iris mode setting Sense UP settingPress the Cursor l, then d or c button until EI Automatic color temperature tracking setting ATW White Balance settingManual white balance MWB White BALANCE/ATWMASKING Masking settingMenu Back END Press and hold the SET button Push-lock white balance adjustment AWCManual white balance setting MWB Short mode Short Electronic Shutter settingLong exposure mode Long For Short mode When Motion is set to ON, Long mode cannot be selected For Long modeIris Sense UP mode has been set. Refer to Motion settingExample Mask area setting function Masking Size setting function SizeSensitivity setting function Sensitivity Alarm interval setting function IntervalÜü, íí, óó, ññ Direction settingV vertical value is flashing, then press the Cursor c button Size settingMotion Size display table Returning to the default setting MOTION/MASKING Menu Back END This sets the movement amplitude of subjects on the screen Sensitivity settingMaximum MOTION/ZOOM, Interval Zoom settingAlarm Sign setting Interval settingCamera ID flashes on-screen when a movement is detected Image is zoomed in when a movement is detectedChecking the detected movements set by the Motion item Active Move Differ Option settings Aperture setting Gamma setting AGC settingPanning For FIX modeOPTION/FIXI Tilt Returning to the default settingsZooming For VAR modeOPTION/VAR ZOOM, Tilt RS-485 setting Mirror settingTerminate setting Address settingAbout SW No SET button Initial settingOperations using the camera Menu screens Operations Using the System ControllerElectronic zoom Operations using the camera command Camera buttonIris level operations Backlight correction settings Setting the Sense UP and electronic shutterWhite balance and AWC-LOCK settings 4321 Menu DisplayMenu Display No picture on the monitor screen TroubleshootingPicture is not clear Camera SpecificationsDimensions mm AccessoriesExclusions