CONNECTIONS
About the Alarm output terminal
Connect this unit to a VCR or a multiplexer. Alarm output
A: Alarm signal output
C: Common
Alarm active
5 V
About 500 msec.
CR
1.1kΩ
SW 1 : Electric PTZ
*
0.68kΩ
CAUTION:
•The digital processing of the settings may disturb the image for a few seconds after the camera is turned on.
•While the menus are being set, noise sent on the lines by peripheral devices may cause the settings to change. In such a case, turn the power off then on again.
Remote controller circuit connections
Use the layout above to make a remote controller and make the connections to the remote input pins (C, R) of the REMOTE terminal as indicated. This will permit remote controlled operation of this unit. (make contact LOW input)
Note:
• | The maximum length of cable for remote controlled operation is |
| 6 m (AWG 24). |
• | If the ZOOM item in the OPTION MENU is set to ON, remote |
| controlled zoom is possible even while the menu screens are |
SW: switch
SW 2 : Electric PTZ
0.91kΩ
SW 3 : Zoom (wide)
1.2kΩ
SW 4 : Zoom (tele)
1.8kΩ
SW 5 : Panning (left)
2.7kΩ
SW 6 : Panning (right)
3.9kΩ
SW 7 : Tilting (upward)
9.1kΩ
SW 8 : Tilting (down)
displayed. |
*Preset: will return to the zoom (pan, tilt) center position.
12 English