Panasonic AWRP120GJ operating instructions Setting an ND filter, ND Filter, ND1

Page 11

Making image adjustments for the selected remote camera (continued)

Setting an ND filter

The ND filter setting can be configured when the selected remote camera uses a lens with an ND filter function.

1. Press the MENU button to turn on its indicator..

2. Open ND FILTER menu [22]..

1.ND FILTER

ND1

3.Turn the F2 dial to select a setting, and then press the F2 dial to confirm the selection..

The settings displayed when you turn the F2 dial differ depending on the model of remote camera connected.

The following shows the menu display on the unit and the setting values of the remote cameras.

 

Remote camera setting values

Menu display

 

AK‑HC1500

AW-HE50

 

AW-HE60

on the unit

AW‑HE120

AK‑HC1800

AW-HE100

 

 

 

 

 

(*1)

ND1

Through

Clear

ND2

1/4

1/4

 

 

 

 

ND3

1/16

1/16

ND4

1/64

1/64

 

 

 

 

(*1) “ND2↓”, “ND3↓”, and “ND4↓” can be displayed by turning the F2 dial but a selection cannot be confirmed by pressing the dial.

Remote camera setting values

Menu display

AW‑HE870

AW‑E860

on the unit

AW‑E750

 

AW‑E650

 

AW‑E350

Off

Off

 

 

On

On

Selecting an ND filter with the USER buttons (USER 1 to USER 8)

The ND filter settings “ND1” to “ND4” can be assigned to the USER buttons (USER 1 to USER 8) to enable selection with the buttons. ⇒“Assigning functions to the USER buttons” (page 30)

1.Press one of the USER buttons (USER 1 to USER 8)..

The indicator of the selected button turns on and the corresponding ND filter is applied.

zzWhen AW‑HE870, AW‑E860, AW‑E750, AW‑E650, or AW‑E350 is connected:

The ND filter of the remote camera can be turned Off and On with the USER button on the unit that has ND1 assigned.

11

Image 11
Contents Operating Instructions Illustrations and screen images in this manual About trademarks and registered trademarksCopyrights AbbreviationsContents How to turn on the power of the remote cameras How to turn on and off the power of the remote cameras„„Turning off the power of all the cameras How to turn off the power of the remote camerasTurning off the power one camera at a time Turning off the power of multiple camerasBars button Making image adjustments for the selected remote cameraColor adjustment section ZzR and B pedestalAutomatically adjusting the white balance Setting the gainSetting the pedestal Setting the white balanceAutomatically adjusting the black balance Setting the black balanceManually adjusting the white balance R and B gain settings Auto tracking white adjustment ATWSetting the shutter speed Setting the detailAdjusting the shutter speed Setting the shutter modeAW‑HE50 Setting the shooting mode Scene 1 to SceneSelecting an ND filter with the User buttons User 1 to User Setting an ND filterND Filter ND1Operate the OSD menu Hold down the Camera OSD button to turn on its indicatorHold down the Camera OSD button to turn off its indicator Operating the osd menu of a remote cameraPmem Operating preset memory PmemZzLighting of number button indicators ZzChanging pagesDeleting preset memory Delete Registering preset memory StoreRecalling preset memory Recall Iris Scope Mode aScope settings and recalled items Recalled item Setting SpeedPM GRP1 Mode Separate Operating preset memory groups Pmem GroupSetting the operation mode SEPARATE/ ALL Creating preset memory groupsPressing a button to recall a preset memory group Recalling preset memory groupsRegistering the preset memory to recall when in ALL mode PM GRP1 Mode ALL3m50s Remained Operating tracing memory TmemRegistering tracing memory Store CAM1 TmemPress Stop button Recalling tracing memory RecallStandby Recall RecallingRestoring Restoring tracing memory RestoreStandby Restore Deleting tracing memory DeleteRecalled item Setting Setting the items to recall when recalling tracing memoryT Curv Configuring the remote camera operation settingsSetting the PAN/TILT lever inclination and speed „„Operation of Speed dialSetting the zooming direction Setting the pan, tilt, zoom, and focus operation directionsSetting the panning direction Setting the tilting directionSpeed with Z Off Setting the minimum lens zoom start speedSetting the focusing direction MIN Speed„„When other remote camera Setting procedure„„When AW-HE50, AW-HE60, or AW-HE120 Controlling a heater or fan Returning a remote cameras to its home positionControlling a defroster Controlling a wiperButton indicator on or blinking Configuring the unit operation settingsEnabling or disabling operation with the Enable buttons Press the Enable buttonEnabling Menu operation Enabling or disabling menu operationDisabling Menu operation LCD Backligh T Off Switching the focus operation and iris operationSetting the LCD panel backlight FOCUS/IRIS StandardUSER1 Assigning functions to the User buttonsINPUT1 Setting linking with a switcher„„Settings for the connection between unit and switcher „„Settings on the switcherBUS AUX Buscont functionEnabling or disabling the Buscont function BuscontEnabling or disabling the Camera Select function Setting the Focus Assist functionFocus Assist function Camera Select view functionT/Z Control CAM Tally IP functionEnabling or disabling the Tally IP function TallyipCAM INF Caminfformat CAM INF AlarmCAM INF function Enabling or disabling the CAM INF functionLoad Memory card operationsZzMemory cards SaveSaving data to a memory card Save Initializing a memory card InitDeleting the files saved to a memory card Delete Loading data from a memory card LoadTally OUT Tally settings„„Settings on remote cameras Tally IN1Power No Alarm Checking alarm informationDisplaying alarm information ALL Setup Returning the unit to the factory default state InitializeSetting items stored on the unit SetupInitialize ALL Returning the unit to the factory default stateSetting items stored on the unit AW‑RP120 CAM OUT1 Registering camera numbers to CAM OUT1 to CAM OUT10Installing the software Setup SoftwareEnter the IP addresses in the IP address boxes Registering the unit in Setup SoftwareSettings for connecting with the remote cameras and switcher Displaying the Setting tab Initializing the IP addresses Executing auto IP settingAcquiring the connection settings Changing the connection destination IP addressesClicking Refresh clears the user name and password Setting user authenticationEnter the same password as above in the Retype password box Campinp POS Campinp ModeOperations of AW-HE2 Campinp CTLDial/button Setting item Remote camera Table of setting items dedicated dials and buttonsFilm Table of setting items menusVideo Table of setting items menus SW Setup SW CTL Operation lock When starting up and switching camera groupsPreset memory MessagesMessages IP connection settingsMemory card Xx Menu IndexIndex プロフェッショナルAVビジネスユニット