Panasonic AWRP120GJ operating instructions Enabling or disabling the Buscont function, Bus Aux

Page 32

Setting the functions for when the unit is linked with the switcher

Set the functions that can be used when there is a link between the unit and switcher.

Each of the functions needs to be set in advance in SW FUNCTION menu [42] and SW INPUT menu [43].

“Registering the camera numbers that will correspond to the image inputs of the switcher” (page 31)

“Enabling or disabling the function for linking with the switcher” (page 31)

BUSCONT function

Select the bus material of the switcher from the unit.

When the BUSCONT function is enabled, the bus material of the switcher can be selected in conjunction with camera selection on the unit.

Note

zzWhen the link setting of a camera number is changed with AUTO IP menu [37], SWAP IP menu [38], or MANUAL IP menu

[39]or a camera number corresponding to an image input of the switcher is changed with SW INPUT menu [43], the bus material of the switcher will not be changed immediately even if the BUSCONT function is enabled. Press one of the camera selection buttons [CAMERA SELECT/GROUP SELECT] to make a selection again.

Enabling or disabling the BUSCONT function

1.Press the MENU button..

2.Open SW FUNCTION menu [42]..

3.Turn the F1 dial to display the “2.  BUSCONT” item..

2.BUSCONT

Off

4.Turn the F2 dial to select “On” or “Off”, and then press the F2 dial to confirm the selection..

On

: Enables the BUSCONT function.

Off

: Disables the BUSCONT function.

zzEnabling and disabling the BUSCONT function can be assigned to a USER button.

Open USER BUTTON menu [35], display one of the “1.  USER1” to “8.  USER8” items, and set “BUSCONT”..

zzWhen the USER button with “BUSCONT” assigned is pressed, the operation is as follows.

Button indicator on : Enables the BUSCONT function.

Button indicator off : Disables the BUSCONT function.

Setting the switcher bus to control with the BUSCONT function

When the BUSCONT function is enabled, you can set the switcher bus to control with a camera selection button [CAMERA SELECT/ GROUP SELECT] on the unit.

1.Press the MENU button..

2.Open SW FUNCTION menu [42]..

3.Turn the F1 dial to display the “3.  BUS” item..

3.BUS

AUX

4.Turn the F2 dial to select a setting, and then press the F2 dial to confirm the setting..

AUX

: The AUX bus of the switcher is the control target.

PVW

: The PVW bus of the switcher is the control target.

PinP

: The PinP bus of the switcher is the control target.

KEY

: The KEY bus of the switcher is the control target.

32

Image 32
Contents Operating Instructions About trademarks and registered trademarks CopyrightsAbbreviations Illustrations and screen images in this manualContents How to turn on and off the power of the remote cameras How to turn on the power of the remote camerasHow to turn off the power of the remote cameras Turning off the power one camera at a timeTurning off the power of multiple cameras „„Turning off the power of all the camerasMaking image adjustments for the selected remote camera Color adjustment sectionZzR and B pedestal Bars buttonSetting the gain Setting the pedestalSetting the white balance Automatically adjusting the white balanceSetting the black balance Manually adjusting the white balance R and B gain settingsAuto tracking white adjustment ATW Automatically adjusting the black balanceSetting the detail Adjusting the shutter speedSetting the shutter mode Setting the shutter speedSetting the shooting mode Scene 1 to Scene AW‑HE50Setting an ND filter ND FilterND1 Selecting an ND filter with the User buttons User 1 to UserHold down the Camera OSD button to turn on its indicator Hold down the Camera OSD button to turn off its indicatorOperating the osd menu of a remote camera Operate the OSD menuOperating preset memory Pmem ZzLighting of number button indicatorsZzChanging pages PmemDeleting preset memory Delete Registering preset memory StoreRecalling preset memory Recall Scope Mode a Scope settings and recalled items Recalled item SettingSpeed IrisOperating preset memory groups Pmem Group Setting the operation mode SEPARATE/ ALLCreating preset memory groups PM GRP1 Mode SeparateRecalling preset memory groups Registering the preset memory to recall when in ALL modePM GRP1 Mode ALL Pressing a button to recall a preset memory groupOperating tracing memory Tmem Registering tracing memory StoreCAM1 Tmem 3m50s RemainedRecalling tracing memory Recall Standby RecallRecalling Press Stop buttonRestoring tracing memory Restore Standby RestoreDeleting tracing memory Delete RestoringSetting the items to recall when recalling tracing memory Recalled item SettingConfiguring the remote camera operation settings Setting the PAN/TILT lever inclination and speed„„Operation of Speed dial T CurvSetting the pan, tilt, zoom, and focus operation directions Setting the panning directionSetting the tilting direction Setting the zooming directionSetting the minimum lens zoom start speed Setting the focusing directionMIN Speed Speed with Z Off„„When other remote camera Setting procedure„„When AW-HE50, AW-HE60, or AW-HE120 Returning a remote cameras to its home position Controlling a defrosterControlling a wiper Controlling a heater or fanConfiguring the unit operation settings Enabling or disabling operation with the Enable buttonsPress the Enable button Button indicator on or blinkingEnabling Menu operation Enabling or disabling menu operationDisabling Menu operation Switching the focus operation and iris operation Setting the LCD panel backlightFOCUS/IRIS Standard LCD Backligh T OffAssigning functions to the User buttons USER1Setting linking with a switcher „„Settings for the connection between unit and switcher„„Settings on the switcher INPUT1Buscont function Enabling or disabling the Buscont functionBuscont BUS AUXSetting the Focus Assist function Focus Assist functionCamera Select view function Enabling or disabling the Camera Select functionTally IP function Enabling or disabling the Tally IP functionTallyip T/Z Control CAMCaminfformat CAM INF Alarm CAM INF functionEnabling or disabling the CAM INF function CAM INFMemory card operations ZzMemory cardsSave LoadInitializing a memory card Init Saving data to a memory card SaveLoading data from a memory card Load Deleting the files saved to a memory card DeleteTally settings „„Settings on remote camerasTally IN1 Tally OUTPower No Alarm Checking alarm informationDisplaying alarm information Returning the unit to the factory default state Initialize Setting items stored on the unitSetup ALL SetupInitialize ALL Returning the unit to the factory default stateSetting items stored on the unit AW‑RP120 Registering camera numbers to CAM OUT1 to CAM OUT10 CAM OUT1Setup Software Installing the softwareRegistering the unit in Setup Software Enter the IP addresses in the IP address boxesSettings for connecting with the remote cameras and switcher Displaying the Setting tab Executing auto IP setting Acquiring the connection settingsChanging the connection destination IP addresses Initializing the IP addressesClicking Refresh clears the user name and password Setting user authenticationEnter the same password as above in the Retype password box Campinp Mode Operations of AW-HE2Campinp CTL Campinp POSTable of setting items dedicated dials and buttons Dial/button Setting item Remote cameraFilm Table of setting items menusVideo Table of setting items menus SW Setup SW CTL When starting up and switching camera groups Preset memoryMessages Operation lockMessages IP connection settingsMemory card Index Xx MenuIndex プロフェッショナルAVビジネスユニット