Panasonic AWRP120GJ Enabling or disabling menu operation, Disabling Menu operation

Page 28

Configuring the unit operation settings (continued)

Enabling or disabling operation of the ENABLE buttons by menu operation

Operation of the ENABLE buttons can be enabled or disabled by menu operation.

Disabling operation prevents erroneous operation because the enable/ disable states become unable to be changed even by pressing the ENABLE buttons.

1.Press the MENU button..

2.Open RP SETUP menu [25]..

3.Turn the F1 dial to display the “4.  ENABLE BUTTON” item..

4.ENABLE BUTTON ACTIVE

4.Turn the F2 dial to select “ACTIVE” or “LOCK”, and then press the F2 dial to confirm the selection..

ACTIVE

: Enables operation of the ENABLE buttons.

LOCK

: Disables operation of the ENABLE buttons.

 

zzSetting this to “LOCK” stores the ENABLE

 

button states (operation is enabled or disabled in

 

accordance with the lighting states), but ENABLE

 

button operation has no effect.

zzConnecting an external device to the TALLY/GPI connector (GPI input: GPI IN 5) on the rear panel enables the “4. ENABLE BUTTON” item to be controlled from the external device.

Each time GPI IN 5 is set to On (30 ms or longer), the setting of the “4. ENABLE BUTTON” item switches between “ACTIVE” and “LOCK”.

Enabling or disabling menu operation

Menu operation can be enabled or disabled.

Disabling MENU operation

1.Press the MENU button..

2.Open RP SETUP menu [25]..

3.Turn the F1 dial to display the “5.  MENU CONTROL” item..

4.Turn the F2 dial to select “LOCK”, and then press the F2 dial to confirm the selection..

5.MENU CONTROL LOCK

Menu is Locked.

“Menu is Locked” appears and menu operation is disabled.

zzMemory (preset memory and tracing memory) operation is still possible even when menu operation is disabled.

Enabling MENU operation

1.Press the MENU button..

2.Open RP SETUP menu [25]..

5.MENU CONTROL LOCK

3.Turn the F2 dial to select “ACTIVE”, and then press the F2 dial to confirm the selection..

Menu operation is enabled.

5.MENU CONTROL ACTIVE

zzConnecting an external device to the TALLY/GPI connector (GPI input: GPI IN 6) on the rear panel enables the “5. MENU CONTROL” item to be controlled from the external device.

Each time GPI IN 6 is set to On (30 ms or longer), the setting of the “5. MENU CONTROL” item switches between “ACTIVE” and “LOCK”.

28

Image 28
Contents Operating Instructions About trademarks and registered trademarks CopyrightsAbbreviations Illustrations and screen images in this manualContents How to turn on and off the power of the remote cameras How to turn on the power of the remote camerasHow to turn off the power of the remote cameras Turning off the power one camera at a timeTurning off the power of multiple cameras „„Turning off the power of all the camerasMaking image adjustments for the selected remote camera Color adjustment sectionZzR and B pedestal Bars buttonSetting the gain Setting the pedestalSetting the white balance Automatically adjusting the white balanceSetting the black balance Manually adjusting the white balance R and B gain settingsAuto tracking white adjustment ATW Automatically adjusting the black balanceSetting the detail Adjusting the shutter speedSetting the shutter mode Setting the shutter speedSetting the shooting mode Scene 1 to Scene AW‑HE50Setting an ND filter ND FilterND1 Selecting an ND filter with the User buttons User 1 to UserHold down the Camera OSD button to turn on its indicator Hold down the Camera OSD button to turn off its indicatorOperating the osd menu of a remote camera Operate the OSD menuOperating preset memory Pmem ZzLighting of number button indicatorsZzChanging pages PmemRecalling preset memory Recall Registering preset memory StoreDeleting preset memory Delete Scope Mode a Scope settings and recalled items Recalled item SettingSpeed IrisOperating preset memory groups Pmem Group Setting the operation mode SEPARATE/ ALLCreating preset memory groups PM GRP1 Mode SeparateRecalling preset memory groups Registering the preset memory to recall when in ALL modePM GRP1 Mode ALL Pressing a button to recall a preset memory groupOperating tracing memory Tmem Registering tracing memory StoreCAM1 Tmem 3m50s RemainedRecalling tracing memory Recall Standby RecallRecalling Press Stop buttonRestoring tracing memory Restore Standby RestoreDeleting tracing memory Delete RestoringSetting the items to recall when recalling tracing memory Recalled item SettingConfiguring the remote camera operation settings Setting the PAN/TILT lever inclination and speed„„Operation of Speed dial T CurvSetting the pan, tilt, zoom, and focus operation directions Setting the panning directionSetting the tilting direction Setting the zooming directionSetting the minimum lens zoom start speed Setting the focusing directionMIN Speed Speed with Z Off„„When AW-HE50, AW-HE60, or AW-HE120 Setting procedure„„When other remote camera Returning a remote cameras to its home position Controlling a defrosterControlling a wiper Controlling a heater or fanConfiguring the unit operation settings Enabling or disabling operation with the Enable buttonsPress the Enable button Button indicator on or blinkingDisabling Menu operation Enabling or disabling menu operationEnabling Menu operation Switching the focus operation and iris operation Setting the LCD panel backlightFOCUS/IRIS Standard LCD Backligh T OffAssigning functions to the User buttons USER1Setting linking with a switcher „„Settings for the connection between unit and switcher„„Settings on the switcher INPUT1Buscont function Enabling or disabling the Buscont functionBuscont BUS AUXSetting the Focus Assist function Focus Assist functionCamera Select view function Enabling or disabling the Camera Select functionTally IP function Enabling or disabling the Tally IP functionTallyip T/Z Control CAMCaminfformat CAM INF Alarm CAM INF functionEnabling or disabling the CAM INF function CAM INFMemory card operations ZzMemory cardsSave LoadInitializing a memory card Init Saving data to a memory card SaveLoading data from a memory card Load Deleting the files saved to a memory card DeleteTally settings „„Settings on remote camerasTally IN1 Tally OUTDisplaying alarm information Checking alarm informationPower No Alarm Returning the unit to the factory default state Initialize Setting items stored on the unitSetup ALL SetupSetting items stored on the unit Returning the unit to the factory default stateInitialize ALL AW‑RP120 Registering camera numbers to CAM OUT1 to CAM OUT10 CAM OUT1Setup Software Installing the softwareRegistering the unit in Setup Software Enter the IP addresses in the IP address boxesSettings for connecting with the remote cameras and switcher Displaying the Setting tab Executing auto IP setting Acquiring the connection settingsChanging the connection destination IP addresses Initializing the IP addressesEnter the same password as above in the Retype password box Setting user authenticationClicking Refresh clears the user name and password Campinp Mode Operations of AW-HE2Campinp CTL Campinp POSTable of setting items dedicated dials and buttons Dial/button Setting item Remote cameraVideo Table of setting items menusFilm Table of setting items menus SW Setup SW CTL When starting up and switching camera groups Preset memoryMessages Operation lockMemory card IP connection settingsMessages Index Xx MenuIndex プロフェッショナルAVビジネスユニット