Panasonic AWRP120GJ operating instructions Setting procedure, „„When AW-HE50, AW-HE60, or AW-HE120

Page 25

Configuring the remote camera operation settings (continued)

Setting the movement ranges (limiter function) of a remote camera

Depending on the installation location, there may be an obstruction in a movement range of a remote camera, and the remote camera may come into contact with that obstruction when the pan or tilt operation is performed.

A malfunction or accident may occur if the remote camera comes into contact with the obstruction so you need to set a limiter in front of the obstruction to prevent contact.

Also set a limiter if there is a subject you do not wish to shoot in a movement range.

From the unit, you can configure the remote camera limiter setting for the direction of each of the up, down, left, and right limits.

Setting procedure

1.Press the MENU button..

2.Open PTZ ADJUST menu [30]..

3.Turn the F1 dial to display the “3.  LIMIT UP” item..

„„When AW-HE50, AW-HE60, or AW-HE120:

4.Turn the F2 dial to select “On”, and then press the F2 dial to confirm the selection..

The position in the up direction of the currently selected remote camera is set as the up limit and the limiter is enabled.

(The setting is stored in the remote camera.)

3.LIMIT UP

Off

Turn the F2 dial..

3.LIMIT UP

On

Press the F2 dial..

3.LIMIT UP

On

zzTurning the F2 dial to display “Off↓” and then pressing the F2 dial to confirm the selection cancels the limiter.

„„When other remote camera

4.Press the F2 dial to confirm the setting..

The position in the up direction of the currently selected remote camera is set as the up limit and the limiter is enabled.

(The setting is stored in the remote camera.)

3.LIMIT UP

EXEC

Press the F2 dial..

3.LIMIT UP

LIMIT ON

zzIf the F2 dial is turned or the F1 dial is turned to display another item and then the “3. LIMIT UP” item is redisplayed, “EXEC↓” reappears on the second line of the LCD panel.

If the F2 dial is pressed at this time, “LIMIT OFF” is displayed and the limiter is cancelled.

5.Turn the F1 dial to display the “4.  LIMIT DOWN”, “5.  LIMIT LEFT”, or “6.  LIMIT RIGHT” item..

Perform the same operation as step 4 to set the down limit, left limit, and right limit.

Menu item

Setting target

LIMIT UP

Up limit

LIMIT DOWN

Down limit

LIMIT LEFT

Left limit

LIMIT RIGHT

Right limit

25

Image 25
Contents Operating Instructions Copyrights About trademarks and registered trademarksAbbreviations Illustrations and screen images in this manualContents How to turn on the power of the remote cameras How to turn on and off the power of the remote camerasTurning off the power one camera at a time How to turn off the power of the remote camerasTurning off the power of multiple cameras „„Turning off the power of all the camerasColor adjustment section Making image adjustments for the selected remote cameraZzR and B pedestal Bars buttonSetting the pedestal Setting the gainSetting the white balance Automatically adjusting the white balanceManually adjusting the white balance R and B gain settings Setting the black balanceAuto tracking white adjustment ATW Automatically adjusting the black balanceAdjusting the shutter speed Setting the detailSetting the shutter mode Setting the shutter speedAW‑HE50 Setting the shooting mode Scene 1 to SceneND Filter Setting an ND filterND1 Selecting an ND filter with the User buttons User 1 to UserHold down the Camera OSD button to turn off its indicator Hold down the Camera OSD button to turn on its indicatorOperating the osd menu of a remote camera Operate the OSD menuZzLighting of number button indicators Operating preset memory PmemZzChanging pages PmemRecalling preset memory Recall Registering preset memory StoreDeleting preset memory Delete Scope settings and recalled items Recalled item Setting Scope Mode aSpeed IrisSetting the operation mode SEPARATE/ ALL Operating preset memory groups Pmem GroupCreating preset memory groups PM GRP1 Mode SeparateRegistering the preset memory to recall when in ALL mode Recalling preset memory groupsPM GRP1 Mode ALL Pressing a button to recall a preset memory groupRegistering tracing memory Store Operating tracing memory TmemCAM1 Tmem 3m50s RemainedStandby Recall Recalling tracing memory RecallRecalling Press Stop buttonStandby Restore Restoring tracing memory RestoreDeleting tracing memory Delete RestoringRecalled item Setting Setting the items to recall when recalling tracing memorySetting the PAN/TILT lever inclination and speed Configuring the remote camera operation settings„„Operation of Speed dial T CurvSetting the panning direction Setting the pan, tilt, zoom, and focus operation directionsSetting the tilting direction Setting the zooming directionSetting the focusing direction Setting the minimum lens zoom start speedMIN Speed Speed with Z Off„„When AW-HE50, AW-HE60, or AW-HE120 Setting procedure„„When other remote camera Controlling a defroster Returning a remote cameras to its home positionControlling a wiper Controlling a heater or fanEnabling or disabling operation with the Enable buttons Configuring the unit operation settingsPress the Enable button Button indicator on or blinkingDisabling Menu operation Enabling or disabling menu operationEnabling Menu operation Setting the LCD panel backlight Switching the focus operation and iris operationFOCUS/IRIS Standard LCD Backligh T OffUSER1 Assigning functions to the User buttons„„Settings for the connection between unit and switcher Setting linking with a switcher„„Settings on the switcher INPUT1Enabling or disabling the Buscont function Buscont functionBuscont BUS AUXFocus Assist function Setting the Focus Assist functionCamera Select view function Enabling or disabling the Camera Select functionEnabling or disabling the Tally IP function Tally IP functionTallyip T/Z Control CAMCAM INF function Caminfformat CAM INF AlarmEnabling or disabling the CAM INF function CAM INFZzMemory cards Memory card operationsSave LoadSaving data to a memory card Save Initializing a memory card InitDeleting the files saved to a memory card Delete Loading data from a memory card Load„„Settings on remote cameras Tally settingsTally IN1 Tally OUTDisplaying alarm information Checking alarm informationPower No Alarm Setting items stored on the unit Returning the unit to the factory default state InitializeSetup ALL SetupSetting items stored on the unit Returning the unit to the factory default stateInitialize ALL AW‑RP120 CAM OUT1 Registering camera numbers to CAM OUT1 to CAM OUT10Installing the software Setup SoftwareEnter the IP addresses in the IP address boxes Registering the unit in Setup SoftwareSettings for connecting with the remote cameras and switcher Displaying the Setting tab Acquiring the connection settings Executing auto IP settingChanging the connection destination IP addresses Initializing the IP addressesEnter the same password as above in the Retype password box Setting user authenticationClicking Refresh clears the user name and password Operations of AW-HE2 Campinp ModeCampinp CTL Campinp POSDial/button Setting item Remote camera Table of setting items dedicated dials and buttonsVideo Table of setting items menusFilm Table of setting items menus SW Setup SW CTL Preset memory When starting up and switching camera groupsMessages Operation lockMemory card IP connection settingsMessages Xx Menu IndexIndex プロフェッショナルAVビジネスユニット