Making image adjustments for the selected remote camera (continued)
Manually adjusting the white balance (R and B gain settings)
1.As with the automatic adjustment, fill the screen with a white subject..
2.Connect the video output of the currently selected remote camera to a waveform monitor..
Setting the black balance
The black balance needs to be adjusted when using a remote camera for the first time or when a remote camera has not been used for a prolonged period of time. It also needs to be adjusted when significant changes have occurred in the ambient temperature or at the change of the seasons.
When the camera will be used with the same settings and under the same conditions, the black balance does not need to be adjusted again. When the black balance is adjusted again, the previous memory data will be erased and replaced with the new black balance settings.
3.Press the WHITE BAL A button to turn on its indicator..
4.Turn the R GAIN dial to select the R channel (red) setting, and turn the B GAIN dial to select the B channel (blue) setting..
The adjustment results are registered to memory A. zzThe setting value is displayed during adjustment.
zzWhen the R GAIN dial and B GAIN dial are pressed, the setting values do not change and are only displayed.
R GAIN : +150
B GAIN : +150
5.Press the WHITE BAL B button to turn on its indicator..
Perform step 4 in the same way as with the WHITE BAL A button to set memory B.
Auto tracking white adjustment (ATW)
You can select the auto tracking white balance (ATW) mode for automatically tracking the white balance in accordance with the lighting conditions.
1.Press the ATW button to turn on its indicator..
ATW mode is enabled.
zzIf there is no white on the screen, it may not be possible to compensate the white balance properly.
Also, it may not be possible to compensate the white balance properly depending on the lighting conditions.
Automatically adjusting the black balance
1.Press the ABB button..
The ABB button indicator blinks and the black balance is adjusted by automatically closing the lens iris.
When adjustment ends successfully, the button indicator turns off and the adjustment results are registered.
When adjustment was not possible, the ABB button indicator blinks continuously.
zzWhen the black balance is adjusted automatically, the R and B PED setting values return to “±0”.
Manually adjusting the black balance (R and B pedestal adjustment)
1.Connect the video output of the currently selected remote camera to a waveform monitor..
2.Press the auto iris button to turn its indicator off..
3.Turn the IRIS dial to close the lens iris..
4.Turn the R PED dial to select the R channel (red) setting, and turn the B PED dial to select the B channel (blue) setting..
zzThe setting value is displayed during adjustment.
zzWhen the R PED dial and B PED dial are pressed, the setting values do not change and are only displayed.
R | PED | : | +150 |
B | PED | : | +150 |
8