Panasonic AWRP120GJ Enabling or disabling the Tally IP function, Tallyip, T/Z Control CAM

Page 34

Setting the functions for when the unit is linked with the switcher (continued)

TALLY IP function

Enable TALLY IP to receive OA tally information from the switcher via the network.

The lighting statuses of the camera status indicators on the unit and the tally lamps on the remote cameras are changed based on the received OA tally information.

Enabling or disabling the TALLY IP function

1.Press the MENU button..

2.Open SW FUNCTION menu [42]..

3.Turn the F1 dial to display the “6.  TALLY_IP” item..

6.TALLY_IP

Off

4.Turn the F2 dial to select “On” or “Off”, and then press the F2 dial to confirm the selection..

On

: Enables the TALLY IP function.

Off

: Disables the TALLY IP function.

zzTo enable tally lamp on instructions to be sent to a remote camera based on the tally information received from the switcher, you need to display the “3. TALLY OUT” item in CAMERA SETUP menu [24] and then set it to “On”.

Note

zzThe unit also sends the tally lamp on instruction to the corresponding remote camera when the unit receives tally information for a camera number belonging to a camera group that is not selected.

Operating the switcher with the PAN/TILT lever and ZOOM button

You can use the unit's PAN/TILT lever and ZOOM button to change switcher settings (PinP position and size, etc.).

Setting the application of the PAN/TILT lever and ZOOM button

1.Press the MENU button..

2.Open SW FUNCTION menu [42]..

3.Turn the F1 dial to display the “7.  P/T/Z CONTROL” item..

7.P/T/Z CONTROL CAM

4.Turn the F2 dial to select a setting, and then press the F2 dial to confirm the selection..

CAM:

Allows you to operate the remote camera selected on the unit with the PAN/TILT lever and ZOOM button.

SW:

Allows you to change the switcher settings with the PAN/TILT lever and ZOOM button.

Button Select:

Allows you to select the operation target of the PAN/TILT lever and ZOOM button (remote cameras or switcher) by pressing the PAN/ TILT ENABLE button or FOCUS/ZOOM/IRIS ENABLE button.

For each of the setting values above, the lighting state of the button indicator changes as follows when the PAN/TILT ENABLE button or FOCUS/ZOOM/IRIS ENABLE button is pressed.

<Change of lighting state when each ENABLE button is pressed>

Setting value

 

 

 

 

Lighting state

 

 

CAM

 

 

On

 

 

 

 

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW

 

 

Blinking

 

 

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Button Select

On

 

 

 

 

Blinking

 

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The following shows the operation with respect to the lighting state of each ENABLE button.

<PAN/TILT ENABLE button>

Button indicator

Operation when the PAN/TILT lever is

state

operated

On

The remote camera is able to move horizontally

 

and vertically.

 

The switcher PinP, wiper, and chroma key marker

Blinking

positions (X, Y) are able to move left/right and

 

up/down.

Off

Operation is disabled.

<ZOOM/FOCUS/IRIS ENABLE button>

Button indicator

Operation when the PAN/TILT lever is

state

operated

On

The lens zoom of the remote camera can be

 

changed.

Blinking

The switcher PinP and chroma key marker sizes

can be changed.

 

Off

Operation is disabled.

34

Image 34
Contents Operating Instructions Abbreviations About trademarks and registered trademarksCopyrights Illustrations and screen images in this manualContents How to turn on and off the power of the remote cameras How to turn on the power of the remote camerasTurning off the power of multiple cameras How to turn off the power of the remote camerasTurning off the power one camera at a time „„Turning off the power of all the camerasZzR and B pedestal Making image adjustments for the selected remote cameraColor adjustment section Bars buttonSetting the white balance Setting the gainSetting the pedestal Automatically adjusting the white balanceAuto tracking white adjustment ATW Setting the black balanceManually adjusting the white balance R and B gain settings Automatically adjusting the black balanceSetting the shutter mode Setting the detailAdjusting the shutter speed Setting the shutter speedSetting the shooting mode Scene 1 to Scene AW‑HE50ND1 Setting an ND filterND Filter Selecting an ND filter with the User buttons User 1 to UserOperating the osd menu of a remote camera Hold down the Camera OSD button to turn on its indicatorHold down the Camera OSD button to turn off its indicator Operate the OSD menuZzChanging pages Operating preset memory PmemZzLighting of number button indicators PmemRecalling preset memory Recall Registering preset memory StoreDeleting preset memory Delete Speed Scope Mode aScope settings and recalled items Recalled item Setting IrisCreating preset memory groups Operating preset memory groups Pmem GroupSetting the operation mode SEPARATE/ ALL PM GRP1 Mode SeparatePM GRP1 Mode ALL Recalling preset memory groupsRegistering the preset memory to recall when in ALL mode Pressing a button to recall a preset memory groupCAM1 Tmem Operating tracing memory TmemRegistering tracing memory Store 3m50s RemainedRecalling Recalling tracing memory RecallStandby Recall Press Stop buttonDeleting tracing memory Delete Restoring tracing memory RestoreStandby Restore RestoringSetting the items to recall when recalling tracing memory Recalled item Setting„„Operation of Speed dial Configuring the remote camera operation settingsSetting the PAN/TILT lever inclination and speed T CurvSetting the tilting direction Setting the pan, tilt, zoom, and focus operation directionsSetting the panning direction Setting the zooming directionMIN Speed Setting the minimum lens zoom start speedSetting the focusing direction Speed with Z Off„„When AW-HE50, AW-HE60, or AW-HE120 Setting procedure„„When other remote camera Controlling a wiper Returning a remote cameras to its home positionControlling a defroster Controlling a heater or fanPress the Enable button Configuring the unit operation settingsEnabling or disabling operation with the Enable buttons Button indicator on or blinkingDisabling Menu operation Enabling or disabling menu operationEnabling Menu operation FOCUS/IRIS Standard Switching the focus operation and iris operationSetting the LCD panel backlight LCD Backligh T OffAssigning functions to the User buttons USER1„„Settings on the switcher Setting linking with a switcher„„Settings for the connection between unit and switcher INPUT1Buscont Buscont functionEnabling or disabling the Buscont function BUS AUXCamera Select view function Setting the Focus Assist functionFocus Assist function Enabling or disabling the Camera Select functionTallyip Tally IP functionEnabling or disabling the Tally IP function T/Z Control CAMEnabling or disabling the CAM INF function Caminfformat CAM INF AlarmCAM INF function CAM INFSave Memory card operationsZzMemory cards LoadInitializing a memory card Init Saving data to a memory card SaveLoading data from a memory card Load Deleting the files saved to a memory card DeleteTally IN1 Tally settings„„Settings on remote cameras Tally OUTDisplaying alarm information Checking alarm informationPower No Alarm Setup Returning the unit to the factory default state InitializeSetting items stored on the unit ALL SetupSetting items stored on the unit Returning the unit to the factory default stateInitialize ALL AW‑RP120 Registering camera numbers to CAM OUT1 to CAM OUT10 CAM OUT1Setup Software Installing the softwareRegistering the unit in Setup Software Enter the IP addresses in the IP address boxesSettings for connecting with the remote cameras and switcher Displaying the Setting tab Changing the connection destination IP addresses Executing auto IP settingAcquiring the connection settings Initializing the IP addressesEnter the same password as above in the Retype password box Setting user authenticationClicking Refresh clears the user name and password Campinp CTL Campinp ModeOperations of AW-HE2 Campinp POSTable of setting items dedicated dials and buttons Dial/button Setting item Remote cameraVideo Table of setting items menusFilm Table of setting items menus SW Setup SW CTL Messages When starting up and switching camera groupsPreset memory Operation lockMemory card IP connection settingsMessages Index Xx MenuIndex プロフェッショナルAVビジネスユニット