Panasonic AWRP120GJ Tally settings, „„Settings on remote cameras, Tally IN1, Tally OUT

Page 39

Tally settings

The unit can receive the tally information of the switcher and other external devices from the TALLY/GPI connector (TALLY input) on the rear panel and two network lines.

To enable turning on the camera status indicators on the unit and the tally lamps on the remote cameras based on the received tally information, you need to configure the following settings.

„„Registering the camera numbers that will correspond to the tally inputs

Setting is required to use TALLY IN1 to TALLY IN10 signals from the TALLY/GPI connector (TALLY input) on the rear panel.

Refer to the relevant explanation in this section.

„„Registering the camera numbers that will correspond to the image inputs of the switcher

Setting is required to use tally information received via the network. Refer to “Setting linking with a switcher” (page 31).

„„Setting the sending of tally information from the unit to remote cameras

Refer to the relevant explanation in this section.

„„Settings on remote cameras

Setting is required on the remote camera to enable turning on the tally lamp.

Refer to the operating instructions for the remote camera.

Registering the camera numbers that will correspond to the tally inputs

1. Press the MENU button..

2. Open TALLY menu [44]..

3. Turn the F1 dial to select the TALLY input connector number..

1.TALLY IN1

CAM1

Input connector number : Select form TALLY IN1 to TALLY IN10

4.Turn the F2 dial to select the corresponding camera number, and then press the F2 dial to confirm the selection..

Camera number : Select from CAM1 to CAM100.

Setting the sending of tally information from the unit to remote cameras

1.Press the MENU button..

2.Open CAMERA SETUP menu [24]..

3.Turn the F1 dial to display the “3.  TALLY OUT” item..

3.TALLY OUT

Off

4.Turn the F2 dial to select “On” or “Off”, and then press the F2 dial to confirm the selection..

On

: Sends tally information to remote cameras.

Off

: Does not send tally information to remote cameras.

39

Image 39
Contents Operating Instructions Illustrations and screen images in this manual About trademarks and registered trademarksCopyrights AbbreviationsContents How to turn on the power of the remote cameras How to turn on and off the power of the remote cameras„„Turning off the power of all the cameras How to turn off the power of the remote camerasTurning off the power one camera at a time Turning off the power of multiple camerasBars button Making image adjustments for the selected remote cameraColor adjustment section ZzR and B pedestalAutomatically adjusting the white balance Setting the gainSetting the pedestal Setting the white balanceAutomatically adjusting the black balance Setting the black balanceManually adjusting the white balance R and B gain settings Auto tracking white adjustment ATWSetting the shutter speed Setting the detailAdjusting the shutter speed Setting the shutter modeAW‑HE50 Setting the shooting mode Scene 1 to SceneSelecting an ND filter with the User buttons User 1 to User Setting an ND filterND Filter ND1Operate the OSD menu Hold down the Camera OSD button to turn on its indicatorHold down the Camera OSD button to turn off its indicator Operating the osd menu of a remote cameraPmem Operating preset memory PmemZzLighting of number button indicators ZzChanging pagesRegistering preset memory Store Recalling preset memory RecallDeleting preset memory Delete Iris Scope Mode aScope settings and recalled items Recalled item Setting SpeedPM GRP1 Mode Separate Operating preset memory groups Pmem GroupSetting the operation mode SEPARATE/ ALL Creating preset memory groupsPressing a button to recall a preset memory group Recalling preset memory groupsRegistering the preset memory to recall when in ALL mode PM GRP1 Mode ALL3m50s Remained Operating tracing memory TmemRegistering tracing memory Store CAM1 TmemPress Stop button Recalling tracing memory RecallStandby Recall RecallingRestoring Restoring tracing memory RestoreStandby Restore Deleting tracing memory DeleteRecalled item Setting Setting the items to recall when recalling tracing memoryT Curv Configuring the remote camera operation settingsSetting the PAN/TILT lever inclination and speed „„Operation of Speed dialSetting the zooming direction Setting the pan, tilt, zoom, and focus operation directionsSetting the panning direction Setting the tilting directionSpeed with Z Off Setting the minimum lens zoom start speedSetting the focusing direction MIN SpeedSetting procedure „„When AW-HE50, AW-HE60, or AW-HE120„„When other remote camera Controlling a heater or fan Returning a remote cameras to its home positionControlling a defroster Controlling a wiperButton indicator on or blinking Configuring the unit operation settingsEnabling or disabling operation with the Enable buttons Press the Enable buttonEnabling or disabling menu operation Disabling Menu operationEnabling Menu operation LCD Backligh T Off Switching the focus operation and iris operationSetting the LCD panel backlight FOCUS/IRIS StandardUSER1 Assigning functions to the User buttonsINPUT1 Setting linking with a switcher„„Settings for the connection between unit and switcher „„Settings on the switcherBUS AUX Buscont functionEnabling or disabling the Buscont function BuscontEnabling or disabling the Camera Select function Setting the Focus Assist functionFocus Assist function Camera Select view functionT/Z Control CAM Tally IP functionEnabling or disabling the Tally IP function TallyipCAM INF Caminfformat CAM INF AlarmCAM INF function Enabling or disabling the CAM INF functionLoad Memory card operationsZzMemory cards SaveSaving data to a memory card Save Initializing a memory card InitDeleting the files saved to a memory card Delete Loading data from a memory card LoadTally OUT Tally settings„„Settings on remote cameras Tally IN1Checking alarm information Displaying alarm informationPower No Alarm ALL Setup Returning the unit to the factory default state InitializeSetting items stored on the unit SetupReturning the unit to the factory default state Setting items stored on the unitInitialize ALL AW‑RP120 CAM OUT1 Registering camera numbers to CAM OUT1 to CAM OUT10Installing the software Setup SoftwareEnter the IP addresses in the IP address boxes Registering the unit in Setup SoftwareSettings for connecting with the remote cameras and switcher Displaying the Setting tab Initializing the IP addresses Executing auto IP settingAcquiring the connection settings Changing the connection destination IP addressesSetting user authentication Enter the same password as above in the Retype password boxClicking Refresh clears the user name and password Campinp POS Campinp ModeOperations of AW-HE2 Campinp CTLDial/button Setting item Remote camera Table of setting items dedicated dials and buttonsTable of setting items menus VideoFilm Table of setting items menus SW Setup SW CTL Operation lock When starting up and switching camera groupsPreset memory MessagesIP connection settings Memory cardMessages Xx Menu IndexIndex プロフェッショナルAVビジネスユニット