Panasonic AWRP120GJ Operations of AW-HE2, Campinp CTL, Campinp Mode, Campinp POS

Page 51

Operations of AW-HE2

AW-HE2 HD integrated cameras can be operated from the unit. This section describes the operations which are different from the corresponding operations of other remote cameras.

Note

zzThe method for connecting AW-HE2 and the unit is the same as that for connecting AW-HE2 and AW-RP50. Refer to the operating instructions supplied with AW-HE2.

<Invalid operations>

Color adjustment

R/B GAIN dial, R/B PED, dial, PED dial, GAIN

section

button, DETAIL button, AUTO GAIN button, ABB

 

button

Focus, zoom, and

FOCUS dial, Auto focus button,

iris section

One-touch auto focus button, FOCUS SPEED

 

dial

User button

SCENE 1 to SCENE 4 buttons (*1)

section

 

(*1) Even if you press these buttons while the SHIFT button indicator is on, the operations will have no effect.

(The shooting mode cannot be selected.)

<Operations which are different>

PAN/TILT lever

When the zoom position is the WIDE end

 

side, the output images do not change even if

 

the lever is operated.

Preset memory

zzThe preset numbers that can be registered

 

and recalled are PMEM 1 to PMEM 9

 

(page number: Page 1).

 

zzPRESET SCOPE and PRESET SPEED

 

cannot be set.

Tracing memory

Up to nine tracing memory can registered and

 

recalled for each camera.

SD card

SAVE and LOAD of the MEM and CAM items

 

cannot be executed.

USER buttons

If the following settings are assigned, PinP

 

display of AW-HE2 can be operated with the

 

USER buttons.

 

CAM_PINP CTL:

 

Displays or hides PinP.

 

Each press of the button switches in the

 

order of display PinP → hide PinP →

 

display PinP, and so on.

 

CAM_PINP MODE:

 

Switches the control target (control mode)

 

of the PAN/TILT lever and ZOOM button.

 

Each press of the button switches in the

 

order of PinP → main screen → PinP, and

 

so on.

 

CAM_PINP POS:

 

Changes the display position of PinP.

 

Each press of the button switches in the

 

order of top right → bottom right → bottom

 

left → top left → top right, and so on.

zzFor the PinP display function of AW-HE2, refer to the operating instructions supplied with AW-HE2.

.

<Invalid menu operations>

Menu

 

Setting item

SHUTTER [21]

1. SHUTTER

 

2. SPEED

ND FILTER [22]

1.

ND FILTER

PTZ ADJUST [30]

2. SPEED WITH Z

 

3.

LIMIT UP

 

4. LIMIT DOWN

 

5.

LIMIT LEFT

 

6.

LIMIT RIGHT

51

Image 51
Contents Operating Instructions Illustrations and screen images in this manual About trademarks and registered trademarksCopyrights AbbreviationsContents How to turn on the power of the remote cameras How to turn on and off the power of the remote cameras„„Turning off the power of all the cameras How to turn off the power of the remote camerasTurning off the power one camera at a time Turning off the power of multiple camerasBars button Making image adjustments for the selected remote cameraColor adjustment section ZzR and B pedestalAutomatically adjusting the white balance Setting the gainSetting the pedestal Setting the white balanceAutomatically adjusting the black balance Setting the black balanceManually adjusting the white balance R and B gain settings Auto tracking white adjustment ATWSetting the shutter speed Setting the detailAdjusting the shutter speed Setting the shutter modeAW‑HE50 Setting the shooting mode Scene 1 to SceneSelecting an ND filter with the User buttons User 1 to User Setting an ND filterND Filter ND1Operate the OSD menu Hold down the Camera OSD button to turn on its indicatorHold down the Camera OSD button to turn off its indicator Operating the osd menu of a remote cameraPmem Operating preset memory PmemZzLighting of number button indicators ZzChanging pagesRegistering preset memory Store Recalling preset memory RecallDeleting preset memory Delete Iris Scope Mode aScope settings and recalled items Recalled item Setting SpeedPM GRP1 Mode Separate Operating preset memory groups Pmem GroupSetting the operation mode SEPARATE/ ALL Creating preset memory groupsPressing a button to recall a preset memory group Recalling preset memory groupsRegistering the preset memory to recall when in ALL mode PM GRP1 Mode ALL3m50s Remained Operating tracing memory TmemRegistering tracing memory Store CAM1 TmemPress Stop button Recalling tracing memory RecallStandby Recall RecallingRestoring Restoring tracing memory RestoreStandby Restore Deleting tracing memory DeleteRecalled item Setting Setting the items to recall when recalling tracing memoryT Curv Configuring the remote camera operation settingsSetting the PAN/TILT lever inclination and speed „„Operation of Speed dialSetting the zooming direction Setting the pan, tilt, zoom, and focus operation directionsSetting the panning direction Setting the tilting directionSpeed with Z Off Setting the minimum lens zoom start speedSetting the focusing direction MIN SpeedSetting procedure „„When AW-HE50, AW-HE60, or AW-HE120„„When other remote camera Controlling a heater or fan Returning a remote cameras to its home positionControlling a defroster Controlling a wiperButton indicator on or blinking Configuring the unit operation settingsEnabling or disabling operation with the Enable buttons Press the Enable buttonEnabling or disabling menu operation Disabling Menu operationEnabling Menu operation LCD Backligh T Off Switching the focus operation and iris operationSetting the LCD panel backlight FOCUS/IRIS StandardUSER1 Assigning functions to the User buttonsINPUT1 Setting linking with a switcher„„Settings for the connection between unit and switcher „„Settings on the switcherBUS AUX Buscont functionEnabling or disabling the Buscont function BuscontEnabling or disabling the Camera Select function Setting the Focus Assist functionFocus Assist function Camera Select view functionT/Z Control CAM Tally IP functionEnabling or disabling the Tally IP function TallyipCAM INF Caminfformat CAM INF AlarmCAM INF function Enabling or disabling the CAM INF functionLoad Memory card operationsZzMemory cards SaveSaving data to a memory card Save Initializing a memory card InitDeleting the files saved to a memory card Delete Loading data from a memory card LoadTally OUT Tally settings„„Settings on remote cameras Tally IN1Checking alarm information Displaying alarm informationPower No Alarm ALL Setup Returning the unit to the factory default state InitializeSetting items stored on the unit SetupReturning the unit to the factory default state Setting items stored on the unitInitialize ALL AW‑RP120 CAM OUT1 Registering camera numbers to CAM OUT1 to CAM OUT10Installing the software Setup SoftwareEnter the IP addresses in the IP address boxes Registering the unit in Setup SoftwareSettings for connecting with the remote cameras and switcher Displaying the Setting tab Initializing the IP addresses Executing auto IP settingAcquiring the connection settings Changing the connection destination IP addressesSetting user authentication Enter the same password as above in the Retype password boxClicking Refresh clears the user name and password Campinp POS Campinp ModeOperations of AW-HE2 Campinp CTLDial/button Setting item Remote camera Table of setting items dedicated dials and buttonsTable of setting items menus VideoFilm Table of setting items menus SW Setup SW CTL Operation lock When starting up and switching camera groupsPreset memory MessagesIP connection settings Memory cardMessages Xx Menu IndexIndex プロフェッショナルAVビジネスユニット