Panasonic AWRP120GJ operating instructions Displaying the Setting tab

Page 48

Setup Software (continued)

Displaying the “Setting” tab

1

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

 

11

 

12

 

13

1Setting target selection list box

Select the unit for which to configure the connection settings.

Click to display the IP addresses of the units that can be set from this software. Select the IP address of the unit you want to set from this list.

Any of the units registered in the “IP Address” tab can be selected. “Registering the unit in Setup Software” (page 46)

2CAMERA/SW

Displays the types of devices to be connected.

CAMERA : Remote camera

SW : Switcher

3CAMERA GROUP

Displays the camera group numbers.

4CAMERA NO..

Displays the camera numbers.

5CTRL TYPE

Select the connection types.

Click on the right and select a connection type from “Serial”, “Network”, or “NoAsign”.

Serial

: Serial connection

Network

: IP connection

NoAsign

: No setting (default setting)

“Serial” can only be selected with GROUP1.

After making a change, click the [SET] button to reflect the change.

6CAMERA NAME

Displays the names of the cameras set on the remote cameras. They are displayed for the remote cameras in the currently selected group.

For remote cameras with a serial connection, a name is only displayed when a

remote camera is selected on the unit.

7SW INPUT

Set the image inputs of the switcher that correspond to the camera numbers on the unit.

Click on the right and select an option from “NoAsign” and “INPUT1” to “INPUT100".

After making a change, click the [SET] button to reflect the change.

8MAC ADDRESS

Displays the MAC addresses of the remote cameras and switcher linked to the camera numbers on the unit.

9IP ADDRESS

Set the IP addresses of the remote cameras and switcher that are connection destinations.

After input, click the [SET] button to reflect the changes.

10CAMERA PORT NO

Set the port numbers of the remote cameras that are connection destinations.

After input, click the [SET] button to reflect the changes. Possible setting range: 1 to 65535

However, the following values cannot be set even though they are within this range.

20, 21, 23, 25, 42, 53, 67, 68, 69, 110, 123, 161, 162, 995, 10669, 10670

11SWAP CAMERA

Swap the remote cameras set as connection destinations between two camera numbers.

Click to display camera numbers “C001” to “C100”.

Select the camera number with which you want to make the swap from this list.

After making a change, click the [SET] button to reflect the change.

12RECEIVE PORT NO

Set the port numbers for the unit to receive camera information update notifications from remote cameras.

Possible setting range: 61000 to 65534

Only an even number can be set.

Even if an odd number is entered and then the [SET] button is clicked, the value is not reflected.

13ALARM

Displays the alarm information of the remote cameras.

It is displayed for the remote cameras belonging to the camera group selected on the unit.

For remote cameras with a serial connection, the information is only displayed when a remote camera is selected on the unit.

48

Image 48
Contents Operating Instructions About trademarks and registered trademarks CopyrightsAbbreviations Illustrations and screen images in this manualContents How to turn on and off the power of the remote cameras How to turn on the power of the remote camerasHow to turn off the power of the remote cameras Turning off the power one camera at a timeTurning off the power of multiple cameras „„Turning off the power of all the camerasMaking image adjustments for the selected remote camera Color adjustment sectionZzR and B pedestal Bars buttonSetting the gain Setting the pedestalSetting the white balance Automatically adjusting the white balanceSetting the black balance Manually adjusting the white balance R and B gain settingsAuto tracking white adjustment ATW Automatically adjusting the black balanceSetting the detail Adjusting the shutter speedSetting the shutter mode Setting the shutter speedSetting the shooting mode Scene 1 to Scene AW‑HE50Setting an ND filter ND FilterND1 Selecting an ND filter with the User buttons User 1 to UserHold down the Camera OSD button to turn on its indicator Hold down the Camera OSD button to turn off its indicatorOperating the osd menu of a remote camera Operate the OSD menuOperating preset memory Pmem ZzLighting of number button indicatorsZzChanging pages PmemRegistering preset memory Store Recalling preset memory RecallDeleting preset memory Delete Scope Mode a Scope settings and recalled items Recalled item SettingSpeed IrisOperating preset memory groups Pmem Group Setting the operation mode SEPARATE/ ALLCreating preset memory groups PM GRP1 Mode SeparateRecalling preset memory groups Registering the preset memory to recall when in ALL modePM GRP1 Mode ALL Pressing a button to recall a preset memory groupOperating tracing memory Tmem Registering tracing memory StoreCAM1 Tmem 3m50s RemainedRecalling tracing memory Recall Standby RecallRecalling Press Stop buttonRestoring tracing memory Restore Standby RestoreDeleting tracing memory Delete RestoringSetting the items to recall when recalling tracing memory Recalled item SettingConfiguring the remote camera operation settings Setting the PAN/TILT lever inclination and speed„„Operation of Speed dial T CurvSetting the pan, tilt, zoom, and focus operation directions Setting the panning directionSetting the tilting direction Setting the zooming directionSetting the minimum lens zoom start speed Setting the focusing directionMIN Speed Speed with Z OffSetting procedure „„When AW-HE50, AW-HE60, or AW-HE120„„When other remote camera Returning a remote cameras to its home position Controlling a defrosterControlling a wiper Controlling a heater or fanConfiguring the unit operation settings Enabling or disabling operation with the Enable buttonsPress the Enable button Button indicator on or blinkingEnabling or disabling menu operation Disabling Menu operationEnabling Menu operation Switching the focus operation and iris operation Setting the LCD panel backlightFOCUS/IRIS Standard LCD Backligh T OffAssigning functions to the User buttons USER1Setting linking with a switcher „„Settings for the connection between unit and switcher„„Settings on the switcher INPUT1Buscont function Enabling or disabling the Buscont functionBuscont BUS AUXSetting the Focus Assist function Focus Assist functionCamera Select view function Enabling or disabling the Camera Select functionTally IP function Enabling or disabling the Tally IP functionTallyip T/Z Control CAMCaminfformat CAM INF Alarm CAM INF functionEnabling or disabling the CAM INF function CAM INFMemory card operations ZzMemory cardsSave LoadInitializing a memory card Init Saving data to a memory card SaveLoading data from a memory card Load Deleting the files saved to a memory card DeleteTally settings „„Settings on remote camerasTally IN1 Tally OUTChecking alarm information Displaying alarm informationPower No Alarm Returning the unit to the factory default state Initialize Setting items stored on the unitSetup ALL SetupReturning the unit to the factory default state Setting items stored on the unitInitialize ALL AW‑RP120 Registering camera numbers to CAM OUT1 to CAM OUT10 CAM OUT1Setup Software Installing the softwareRegistering the unit in Setup Software Enter the IP addresses in the IP address boxesSettings for connecting with the remote cameras and switcher Displaying the Setting tab Executing auto IP setting Acquiring the connection settingsChanging the connection destination IP addresses Initializing the IP addressesSetting user authentication Enter the same password as above in the Retype password boxClicking Refresh clears the user name and password Campinp Mode Operations of AW-HE2Campinp CTL Campinp POSTable of setting items dedicated dials and buttons Dial/button Setting item Remote cameraTable of setting items menus VideoFilm Table of setting items menus SW Setup SW CTL When starting up and switching camera groups Preset memoryMessages Operation lockIP connection settings Memory cardMessages Index Xx MenuIndex プロフェッショナルAVビジネスユニット