Operating preset memory (PMEM) (continued)
Registering preset memory (STORE)
1.Press one of the camera selection buttons [CAMERA SELECT/GROUP SELECT] to select the remote camera to be operated..
2.Output the images to be shot to the monitor..
3.Press the PMEM button to turn on its indicator..
4.Press the MEM STORE button to turn on its indicator..
5.Operate the PAN/TILT lever and ZOOM button to determine the camera angle to register..
If necessary, adjust the focus and iris as well.
6.Hold down a number button to specify the preset number to register..
“STORE COMPLETE” appears on the second line of the LCD panel. The current camera positions and settings are registered to the preset memory of the remote camera.
zzTo continue registering different camera angles to a preset memory belonging to the same “page number”, repeat steps 5 to 6.
Notes
zzWhen registering preset data, hold down the number button. zzIf a number button that already has preset memory registered
is held down, the saved data will be deleted as it will be overwritten.
Recalling preset memory (RECALL)
1.Press one of the camera selection buttons [CAMERA SELECT/GROUP SELECT] to select the remote camera to be operated..
2.Press the PMEM button to turn on its indicator..
3.Hold down a number button to specify the preset number to recall..
The registered settings are recalled.
zzWhen the indicator of the MEM STORE button or MEM DELETE button is on, preset memory is not recalled when a number button is pressed.
Press the PMEM button or press the MEM STORE button or MEM DELETE button with the indicator turned on to turn off its indicator, and then perform the operation.
Deleting preset memory (DELETE)
1.Press one of the camera selection buttons [CAMERA SELECT/GROUP SELECT] to select the remote camera to be operated..
2.Press the PMEM button to turn on its indicator..
3.Press the MEM DELETE button to turn on its indicator..
4.Hold down a number button to specify the preset number to delete..
“DELETE COMPLETE” appears on the second line of the LCD panel and the registered settings are deleted.
Notes
zzWhen deleting preset data, hold down the number button. zzWhen the preset number used with tracing memory is held down, the tracing data is also deleted at the same time.
⇒For details on tracing memory, refer to “Operating tracing memory (TMEM)” (page 18).
14