Operating tracing memory (TMEM) (continued)
Deleting tracing memory (DELETE)
1.Press one of the camera selection buttons [CAMERA SELECT/GROUP SELECT] to select the remote camera to be operated..
2.Press the TMEM button to turn on its indicator..
The tracing memory status appears.
The indicators of number buttons with registered tracing memory turn on.
Selected camera number
CAM1 TMEM
3m50s Remained.
Remaining possible recording time (max.. 5 m 00 s)
Note
zzA button with no tracing memory registered does not turn on even when it is a button with preset memory registered.
3.Press the MEM DELETE button to turn on its indicator..
4.Hold down one of the number buttons [1] to [10] that has its indicator turned on to specify the tracing memory number..
The registered preset memory and tracing memory are deleted.
Restoring tracing memory (RESTORE)
1.Press one of the camera selection buttons [CAMERA SELECT/GROUP SELECT] to select the remote camera to be controlled from the unit..
2.Output the images to be shot to the monitor..
3.Press the TMEM button to turn on its indicator..
The tracing memory status appears.
The indicators of number buttons with registered tracing memory turn on.
Selected camera number
CAM1 TMEM
3m50s Remained.
Remaining possible recording time (max.. 5 m 00 s)
Note
zzA button with no tracing memory registered does not turn on even when it is a button with preset memory registered.
4.Press the RESTORE button to turn on its indicator..
5.Press one of the number buttons [1] to [10] that has its indicator turned on..
The remote camera moves to the start position.
The indicators of the number button that was pressed and START button [11] blink. (Restore standby state)
zzAt this time, you can operate the PAN/TILT lever to change the start position.
TM03:0m00s/ 0 m 5 0 s
Standby Restore.
6.Press START button [11]..
The tracing memory is recalled and the remote camera starts moving.
Total time of tracing memory
Current recall position during recalling
TM03:0m20s/ 0 m 5 0 s
Restoring.
20