Panasonic AWRP120GJ Deleting tracing memory Delete, Restoring tracing memory Restore

Page 20

Operating tracing memory (TMEM) (continued)

Deleting tracing memory (DELETE)

1.Press one of the camera selection buttons [CAMERA SELECT/GROUP SELECT] to select the remote camera to be operated..

2.Press the TMEM button to turn on its indicator..

The tracing memory status appears.

The indicators of number buttons with registered tracing memory turn on.

Selected camera number

CAM1 TMEM

3m50s Remained.

Remaining possible recording time (max.. 5 m 00 s)

Note

zzA button with no tracing memory registered does not turn on even when it is a button with preset memory registered.

3.Press the MEM DELETE button to turn on its indicator..

4.Hold down one of the number buttons [1] to [10] that has its indicator turned on to specify the tracing memory number..

The registered preset memory and tracing memory are deleted.

Restoring tracing memory (RESTORE)

1.Press one of the camera selection buttons [CAMERA SELECT/GROUP SELECT] to select the remote camera to be controlled from the unit..

2.Output the images to be shot to the monitor..

3.Press the TMEM button to turn on its indicator..

The tracing memory status appears.

The indicators of number buttons with registered tracing memory turn on.

Selected camera number

CAM1 TMEM

3m50s Remained.

Remaining possible recording time (max.. 5 m 00 s)

Note

zzA button with no tracing memory registered does not turn on even when it is a button with preset memory registered.

4.Press the RESTORE button to turn on its indicator..

5.Press one of the number buttons [1] to [10] that has its indicator turned on..

The remote camera moves to the start position.

The indicators of the number button that was pressed and START button [11] blink. (Restore standby state)

zzAt this time, you can operate the PAN/TILT lever to change the start position.

TM03:0m00s/ 0 m 5 0 s

Standby Restore.

6.Press START button [11]..

The tracing memory is recalled and the remote camera starts moving.

Total time of tracing memory

Current recall position during recalling

TM03:0m20s/ 0 m 5 0 s

Restoring.

20

Image 20
Contents Operating Instructions About trademarks and registered trademarks CopyrightsAbbreviations Illustrations and screen images in this manualContents How to turn on and off the power of the remote cameras How to turn on the power of the remote camerasHow to turn off the power of the remote cameras Turning off the power one camera at a timeTurning off the power of multiple cameras „„Turning off the power of all the camerasMaking image adjustments for the selected remote camera Color adjustment sectionZzR and B pedestal Bars buttonSetting the gain Setting the pedestalSetting the white balance Automatically adjusting the white balanceSetting the black balance Manually adjusting the white balance R and B gain settingsAuto tracking white adjustment ATW Automatically adjusting the black balanceSetting the detail Adjusting the shutter speedSetting the shutter mode Setting the shutter speedSetting the shooting mode Scene 1 to Scene AW‑HE50Setting an ND filter ND FilterND1 Selecting an ND filter with the User buttons User 1 to UserHold down the Camera OSD button to turn on its indicator Hold down the Camera OSD button to turn off its indicatorOperating the osd menu of a remote camera Operate the OSD menuOperating preset memory Pmem ZzLighting of number button indicatorsZzChanging pages PmemDeleting preset memory Delete Registering preset memory StoreRecalling preset memory Recall Scope Mode a Scope settings and recalled items Recalled item SettingSpeed IrisOperating preset memory groups Pmem Group Setting the operation mode SEPARATE/ ALLCreating preset memory groups PM GRP1 Mode SeparateRecalling preset memory groups Registering the preset memory to recall when in ALL modePM GRP1 Mode ALL Pressing a button to recall a preset memory groupOperating tracing memory Tmem Registering tracing memory StoreCAM1 Tmem 3m50s RemainedRecalling tracing memory Recall Standby RecallRecalling Press Stop buttonRestoring tracing memory Restore Standby RestoreDeleting tracing memory Delete RestoringSetting the items to recall when recalling tracing memory Recalled item SettingConfiguring the remote camera operation settings Setting the PAN/TILT lever inclination and speed„„Operation of Speed dial T CurvSetting the pan, tilt, zoom, and focus operation directions Setting the panning directionSetting the tilting direction Setting the zooming directionSetting the minimum lens zoom start speed Setting the focusing directionMIN Speed Speed with Z Off„„When other remote camera Setting procedure„„When AW-HE50, AW-HE60, or AW-HE120 Returning a remote cameras to its home position Controlling a defrosterControlling a wiper Controlling a heater or fanConfiguring the unit operation settings Enabling or disabling operation with the Enable buttonsPress the Enable button Button indicator on or blinkingEnabling Menu operation Enabling or disabling menu operationDisabling Menu operation Switching the focus operation and iris operation Setting the LCD panel backlightFOCUS/IRIS Standard LCD Backligh T OffAssigning functions to the User buttons USER1Setting linking with a switcher „„Settings for the connection between unit and switcher„„Settings on the switcher INPUT1Buscont function Enabling or disabling the Buscont functionBuscont BUS AUXSetting the Focus Assist function Focus Assist functionCamera Select view function Enabling or disabling the Camera Select functionTally IP function Enabling or disabling the Tally IP functionTallyip T/Z Control CAMCaminfformat CAM INF Alarm CAM INF functionEnabling or disabling the CAM INF function CAM INFMemory card operations ZzMemory cardsSave LoadInitializing a memory card Init Saving data to a memory card SaveLoading data from a memory card Load Deleting the files saved to a memory card DeleteTally settings „„Settings on remote camerasTally IN1 Tally OUTPower No Alarm Checking alarm informationDisplaying alarm information Returning the unit to the factory default state Initialize Setting items stored on the unitSetup ALL SetupInitialize ALL Returning the unit to the factory default stateSetting items stored on the unit AW‑RP120 Registering camera numbers to CAM OUT1 to CAM OUT10 CAM OUT1Setup Software Installing the softwareRegistering the unit in Setup Software Enter the IP addresses in the IP address boxesSettings for connecting with the remote cameras and switcher Displaying the Setting tab Executing auto IP setting Acquiring the connection settingsChanging the connection destination IP addresses Initializing the IP addressesClicking Refresh clears the user name and password Setting user authenticationEnter the same password as above in the Retype password box Campinp Mode Operations of AW-HE2Campinp CTL Campinp POSTable of setting items dedicated dials and buttons Dial/button Setting item Remote cameraFilm Table of setting items menusVideo Table of setting items menus SW Setup SW CTL When starting up and switching camera groups Preset memoryMessages Operation lockMessages IP connection settingsMemory card Index Xx MenuIndex プロフェッショナルAVビジネスユニット