CLEARING TITLE/TIME/DATE TEXT DISPLAY ON ALL CHANNELS

You can clear title/time/date text on all CM9760-MDA channels using a DIP switch method.

To do so, proceed as follows:

1.Turn off the MDA.

2.Set the MDA to unit ID 33:

a.Set DIP switches 1, 2, 3, 4, and 5 to the OFF position.

b.Set DIP switch 6 to the ON position.

3.Turn on the MDA.

A 30-second timer starts.

4.Before the 30 seconds elapses, change the unit ID to a setting other than unit ID 33 using the appropriate DIP switch settings.

After 30 seconds have elapsed, the MDA checks whether the unit ID is different from the initial setting of 33. If the unit ID has changed, the MDA title/time/date text display is cleared.

Note the following:

¥The title/time/date text can be programmed again using the PC or a CM9760-KBD, KBD200A, or KBD300A keyboard.

¥If the MDA must be set back to unit ID 33, set the unit ID after the title/time/date text has cleared.

VIDEO CONNECTIONS

Table C. Video Coaxial Cable Wiring Distances

Cable Type*

Maximum Distance

 

 

RG59/U

750 ft (229 m)

RG6/U

1,000 ft (305 m)

RG11/U

1,500 ft (457 m)

 

 

*Minimum cable requirements: 75 ohms impedance All-copper center conductor

All-copper braided shield with 95% braid coverage

1.Connect the remote video sources to the input BNC connectors on the rear panel of the MDA (refer to Figure 33). Refer to Table C for video coaxial wiring distances. (Note that when wiring inputs it is good installation practice to label each video input in case troubleshooting is required.)

2.Connect cables from the output BNC connectors on the MDAÕs rear panel to the input connectors of monitors, VCRs, switchers, etc. (refer to Figure 33). Refer to Table C for video coaxial wiring distances.

Although the MDA does not pass Coaxitron signals, it can be used with Coaxitron products Ñsuch as the CM6700, CM6800, and CM9760-CXTAÑby installing the MDA after the Coaxitron equipment (refer to Figure 45 and to Figure 46).

10

Pelco Manual C573M-D (11/03)

Image 11
Contents Important Notice System Contents CM9760-CC1 Connection to over 16 MDA Units List of IllustrationsList of Tables Master MDA Time and Date Generator for 63 MDA Slave UnitsOverview Important Safeguards and WarningsDescription System Configuration Rear Panel View Communication Hardware SetupMounting ModelsSwitch Settings Port Setup Selected Communication Ports SetupCameras Address Setup for Daisy ChainingSwitch Settings Camera Range Selected Resetting to Factory Defaults Setting UP a Unit AS the Master ClockCable Type Maximum Distance Clearing TITLE/TIME/DATE Text Display on ALL ChannelsVideo Connections Data Connections Connecting the MDA to a System 9740/9760 ControllerTransmit Transmit + No Connection Ground Receive Receive + Connecting the MDA to AN External PCPin Out RS-232 Function RS-422 Function RS-485 Function Connecting the MDA to a KBD200A or KBD300A Keyboard Connecting the MDA to a CM9760-KBD KeyboardPower Connections Keyboard WiringProgramming with a Keyboard Time and Date SetupProgramming Programming MethodsÒhost Direct CAM CTRL.Ó Entering the Programming Mode with the CM9760-KBDSET Camera Title Main MenuSET Camera Display SET Cable CompensationDisplay Enable TimeEnable Video PositionTable E. CM9760-CC1/CM9760-MDA Format Matchup SET Time and DateDEC-31-02 115952 PMData Bits SET PortProtocol Baud RateParity Reset MDASystem Requirements Stop BitsInstalling the CM9760-MDA Setup Program Login Dialog Box Starting the CM9760-MDA Setup ProgramSET Password CM9760-MDA Setup Dialog BOXEnter the Unit ID number 1-64, and then click OK SET Unit IDSET System System Communication Setup Dialog Box Set Time and Date Dialog Box CM9760-CC1 CM9760-MDA SET TitlesPelco Manual C573M-D 11/03 Set Cable Compensation Dialog Box SET Display Position Text Dialog Box Message Text Editing Dialog Box SET Message TextCommand Data Window Pelco Manual C573M-D 11/03 Sample Display Screen Example Sample Command Data Window Pelco Manual C573M-D 11/03 Video Alphanumeric Overlays Send DataSymptom Possible Problem Possible Solution TroubleshootingSpecifications Ratings GeneralAppendix a Applications Simple System Configuration Shielded Twisted Pair RS-422 RS-232 CM9760-MDACM9760-CDU-T PV130CM9760-CC1 Connection to up to 16 Daisy-Chained MDA Units COM1 COM2 MDA Connected to Multiplexers = Data Non-Coaxitron System SetupCoaxitron with System 9760 Setup Coaxitron with System 6800 Setup CM9760-MDA Message Text Sent from Third-Party Equipment Asterisk Appendix B Supported Title and Message Text CharactersCommand Function Command Format Appendix C Message Text Insertion CommandsPelco Manual C573M-D 11/03 Radio and Television Interference Regulatory NoticesRevision History Warranty and Return Information