Pelco cs73m-d Position, Display, Brightness, Enable Time, Date, Enable Video, Output

Page 20

NOTE: At least one output display must be turned on and you must use this out- put on a monitor to see its position.

The fields (or items to be set) are defined as follows:

POSITION

The first item to set is the display position, which is digitally selected

DISPLAY

and controlled by the keyboard. To move the output display, position

 

the cursor at item 1. The Ò1Ó flashes. Press the joystick right to choose

 

the item. Press the joystick up/down and left/right to position the

 

display on the monitor. See Figure 35 for the output display. At least

 

one output display must be on and you must use this output on a

 

monitor to see its position. To return to the Camera Display Menu after

 

setting the position display, press the OPEN or CLOSE key.

BRIGHTNESS

To set brightness, press the joystick down to position the cursor at the

 

brightness item on the menu. Use the OPEN key to increase

 

brightness and the CLOSE key to decrease it. Brightness numbers

 

range from 1 (darkest) to 8 (brightest). Brightness changes on the

 

menu as you change the number.

ENABLE TITLES You toggle this field on/off by placing the cursor on the selection and pressing the OPEN key. You can activate or deactivate the titles on a camera-by-camera basis. The selection immediately appears on the menu.

ENABLE TIME

You toggle this field on/off by placing the cursor on the selection and

DATE

pressing the OPEN key. You can activate or deactivate the time and

 

date on a camera-by-camera basis. The selection immediately appears

 

on the menu.

ENABLE VIDEO

Use this field to direct the alphanumeric data (text) to the desired

DISPLAY

output. In the example in Figure 12, outputs 1 and 3 will have alpha-

OUTPUT

numeric information while outputs 2 and 4 will not. To change the

 

settings, position the cursor at locations A, B, C, or D and press the

 

OPEN or CLOSE key to turn the settings ON or OFF.

As shipped from the factory, the four outputs for the title, time, and date display are ON. Brightness is set to level 5.

Position the cursor at RETURN and press the joystick right to return to the Main Menu. You can also press the NEAR key to exit this menu.

Pelco Manual C573M-D (11/03)

19

Image 20
Contents Important Notice System Contents List of Illustrations List of TablesMaster MDA Time and Date Generator for 63 MDA Slave Units CM9760-CC1 Connection to over 16 MDA UnitsOverview Important Safeguards and WarningsDescription System Configuration Rear Panel View Hardware Setup MountingModels CommunicationCommunication Ports Setup Switch Settings Port Setup SelectedCameras Address Setup for Daisy ChainingSwitch Settings Camera Range Selected Setting UP a Unit AS the Master Clock Resetting to Factory DefaultsCable Type Maximum Distance Clearing TITLE/TIME/DATE Text Display on ALL ChannelsVideo Connections Connecting the MDA to a System 9740/9760 Controller Data ConnectionsTransmit Transmit + No Connection Ground Receive Receive + Connecting the MDA to AN External PCPin Out RS-232 Function RS-422 Function RS-485 Function Connecting the MDA to a CM9760-KBD Keyboard Connecting the MDA to a KBD200A or KBD300A KeyboardKeyboard Wiring Power ConnectionsTime and Date Setup ProgrammingProgramming Methods Programming with a Keyboard Entering the Programming Mode with the CM9760-KBD Òhost Direct CAM CTRL.ÓMain Menu SET Camera TitleSET Cable Compensation SET Camera DisplayEnable Time Enable VideoPosition DisplaySET Time and Date DEC-31-02115952 PM Table E. CM9760-CC1/CM9760-MDA Format MatchupSET Port ProtocolBaud Rate Data BitsReset MDA System RequirementsStop Bits ParityInstalling the CM9760-MDA Setup Program Starting the CM9760-MDA Setup Program Login Dialog BoxCM9760-MDA Setup Dialog BOX SET PasswordEnter the Unit ID number 1-64, and then click OK SET Unit IDSET System System Communication Setup Dialog Box Set Time and Date Dialog Box SET Titles CM9760-CC1 CM9760-MDAPelco Manual C573M-D 11/03 Set Cable Compensation Dialog Box SET Display Position Text Dialog Box SET Message Text Message Text Editing Dialog BoxCommand Data Window Pelco Manual C573M-D 11/03 Sample Display Screen Example Sample Command Data Window Pelco Manual C573M-D 11/03 Send Data Video Alphanumeric OverlaysTroubleshooting Symptom Possible Problem Possible SolutionSpecifications General RatingsAppendix a Applications Simple System Configuration Shielded Twisted Pair RS-232 CM9760-MDA RS-422PV130 CM9760-CDU-TCM9760-CC1 Connection to up to 16 Daisy-Chained MDA Units COM1 COM2 MDA Connected to Multiplexers Non-Coaxitron System Setup = DataCoaxitron with System 9760 Setup Coaxitron with System 6800 Setup CM9760-MDA Message Text Sent from Third-Party Equipment Appendix B Supported Title and Message Text Characters AsteriskAppendix C Message Text Insertion Commands Command Function Command FormatPelco Manual C573M-D 11/03 Regulatory Notices Radio and Television InterferenceWarranty and Return Information Revision History