Pelco cs73m-d operation manual System Configuration Rear Panel View

Page 6

CAMERA

CAMERA INPUT

1

2

3

4

5

6

7

INPUT

10

11

12

13

14

15

16

 

8

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PGM

120VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MON

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM1 COM2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT ID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

PELCO CM9760-MDA

PELCO SYSTEM CM9760 OR

PC CONNECTED TO COM1 PORT

MONITORVCR

Figure 1. System Configuration (Rear Panel View)

NOTE: Up to 16 MDA units can be daisy-chained. If more than 16 MDAs are required, a CM9760-CDU-T must be used.

The MDA can be programmed using a PC or a CM9760-KBD, KBD200A, or KBD300A keyboard. Each of the 16 video inputs can be individually programmed to insert time/date and title information on each video output, and each video output is selectable to include or exclude time/date and title generation. Character positions are adjustable horizontally and vertically on-screen with digital brightness control. Programming also includes cable compensation for up to 1,500 feet (457 m) of RG59/U coaxial cable.

The MDA can act as a stand-alone time/date and title generator or can be synchronized to a System 9740ª/System 9760¨ as a matrix time/date and title generator:

¥As a stand-alone unit, an MDA can be addressed to provide the master time and date for up to 63 MDA slave units.

¥When connected to a System 9740/System 9760 CC1 port, up to 64 MDAs can accept the master time and date from the 9740/9760.

In addition, note the following about the MDA:

¥Using the RS-232 or RS-422 communication standard, the MDA can accept text messages from third-party equipment. A message can contain up to 24 characters. Up to five lines of messages can be displayed simultaneously. The messages can be inserted onto any video channel independently. For additional information, refer to the Set Message Text section of this manual.

¥All video inputs are individually ground isolated to prevent ground loops, eliminating the need for ground loop isolation transformers.

¥Battery backup protects programming information for a minimum of one year.

¥The MDA does not pass Coaxitron¨ signals; however, the MDA can be used with Coaxitron products such as the CM6700, CM6800, and the CM9760-CXTA.

Pelco Manual C573M-D (11/03)

5

Image 6
Contents Important Notice System Contents Master MDA Time and Date Generator for 63 MDA Slave Units List of IllustrationsList of Tables CM9760-CC1 Connection to over 16 MDA UnitsImportant Safeguards and Warnings DescriptionOverview System Configuration Rear Panel View Models Hardware SetupMounting CommunicationCommunication Ports Setup Switch Settings Port Setup SelectedAddress Setup for Daisy Chaining Switch Settings Camera Range SelectedCameras Setting UP a Unit AS the Master Clock Resetting to Factory DefaultsClearing TITLE/TIME/DATE Text Display on ALL Channels Video ConnectionsCable Type Maximum Distance Connecting the MDA to a System 9740/9760 Controller Data ConnectionsConnecting the MDA to AN External PC Pin Out RS-232 Function RS-422 Function RS-485 FunctionTransmit Transmit + No Connection Ground Receive Receive + Connecting the MDA to a CM9760-KBD Keyboard Connecting the MDA to a KBD200A or KBD300A KeyboardKeyboard Wiring Power ConnectionsProgramming Methods Time and Date SetupProgramming Programming with a KeyboardEntering the Programming Mode with the CM9760-KBD Òhost Direct CAM CTRL.ÓMain Menu SET Camera TitleSET Cable Compensation SET Camera DisplayPosition Enable TimeEnable Video Display115952 PM SET Time and DateDEC-31-02 Table E. CM9760-CC1/CM9760-MDA Format MatchupBaud Rate SET PortProtocol Data BitsStop Bits Reset MDASystem Requirements ParityInstalling the CM9760-MDA Setup Program Starting the CM9760-MDA Setup Program Login Dialog BoxCM9760-MDA Setup Dialog BOX SET PasswordSET Unit ID SET SystemEnter the Unit ID number 1-64, and then click OK System Communication Setup Dialog Box Set Time and Date Dialog Box SET Titles CM9760-CC1 CM9760-MDAPelco Manual C573M-D 11/03 Set Cable Compensation Dialog Box SET Display Position Text Dialog Box SET Message Text Message Text Editing Dialog BoxCommand Data Window Pelco Manual C573M-D 11/03 Sample Display Screen Example Sample Command Data Window Pelco Manual C573M-D 11/03 Send Data Video Alphanumeric OverlaysTroubleshooting Symptom Possible Problem Possible SolutionSpecifications General RatingsAppendix a Applications Simple System Configuration Shielded Twisted Pair RS-232 CM9760-MDA RS-422PV130 CM9760-CDU-TCM9760-CC1 Connection to up to 16 Daisy-Chained MDA Units COM1 COM2 MDA Connected to Multiplexers Non-Coaxitron System Setup = DataCoaxitron with System 9760 Setup Coaxitron with System 6800 Setup CM9760-MDA Message Text Sent from Third-Party Equipment Appendix B Supported Title and Message Text Characters AsteriskAppendix C Message Text Insertion Commands Command Function Command FormatPelco Manual C573M-D 11/03 Regulatory Notices Radio and Television InterferenceWarranty and Return Information Revision History