Pelco cs73m-d operation manual Simple System Configuration

Page 46

NOTE: As illustrated in Figures 45 and 46, the MDA can be used with Coaxitron products such as the CM9760-CXTA, CM6800, and CM6700. Note that the MDA must be placed after the Coaxitron equipment. If the MDA is placed incor- rectly, camera control may be adversely affected.

¥Figure 44 illustrates a non-Coaxitron setup that includes an MDA connected to a 9760 keyboard, CM9760-CC1 CPU, and CM9760-MXB matrix bay. The MDA accepts the master time and date from the CM9760-CC1; therefore, the MDA must be set to slave mode.

¥Figure 45 illustrates a Coaxitron setup that includes a System 9760 connected to an MDA. The MDA accepts the master time and date from the CM9760-CC1; therefore, the MDA must be set to slave mode.

¥Figure 46 illustrates a CM6800 connected to an MDA. The MDA accepts the master time and date from the CM6800; therefore, the MDA must be set to slave mode. (The MDA can also accept the master time and date from the CM6700.)

¥Figure 47 illustrates an MDA that accepts message text from third-party equipment. The third-party equipment connects to a COM port (COM 1 or COM 2) of the MDA using the RS-232 or RS-422 communication standard. For cabling requirements, refer to the Data Connections section of this manual. For information about COM port DIP switch settings required for RS-232 and RS-422 communication, refer to the Commu- nication Ports Setup section of this manual. For a wiring diagram of the MDA using RS-232 communication, refer to the Connecting the MDA to an External PC section of this manual. For information about MDA COM port pinouts using RS-422 communica- tion, refer to Table D in this manual. Note that when connecting the MDA to third-party equipment using RS-422 communication, TX+ must connect to RX+ and TX- must connect to RX-. For information about support of message text insertion by the MDA, refer to the Set Message Text section of this manual and to Appendix C.

CAMERA

CAMERA INPUT

1

2

3

4

5

6

7

INPUT

10

11

12

13

14

15

16

 

8

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PGM

120VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MON

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM1 COM2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT ID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

PELCO CM9760-MDA

MONITORVCR

Figure 37. Simple System Configuration

Pelco Manual C573M-D (11/03)

45

Image 46
Contents Important Notice System Contents Master MDA Time and Date Generator for 63 MDA Slave Units List of IllustrationsList of Tables CM9760-CC1 Connection to over 16 MDA UnitsDescription Important Safeguards and WarningsOverview System Configuration Rear Panel View Models Hardware SetupMounting CommunicationCommunication Ports Setup Switch Settings Port Setup SelectedSwitch Settings Camera Range Selected Address Setup for Daisy ChainingCameras Setting UP a Unit AS the Master Clock Resetting to Factory DefaultsVideo Connections Clearing TITLE/TIME/DATE Text Display on ALL ChannelsCable Type Maximum Distance Connecting the MDA to a System 9740/9760 Controller Data ConnectionsPin Out RS-232 Function RS-422 Function RS-485 Function Connecting the MDA to AN External PCTransmit Transmit + No Connection Ground Receive Receive + Connecting the MDA to a CM9760-KBD Keyboard Connecting the MDA to a KBD200A or KBD300A KeyboardKeyboard Wiring Power ConnectionsProgramming Methods Time and Date SetupProgramming Programming with a KeyboardEntering the Programming Mode with the CM9760-KBD Òhost Direct CAM CTRL.ÓMain Menu SET Camera TitleSET Cable Compensation SET Camera DisplayPosition Enable TimeEnable Video Display115952 PM SET Time and DateDEC-31-02 Table E. CM9760-CC1/CM9760-MDA Format MatchupBaud Rate SET PortProtocol Data BitsStop Bits Reset MDASystem Requirements ParityInstalling the CM9760-MDA Setup Program Starting the CM9760-MDA Setup Program Login Dialog BoxCM9760-MDA Setup Dialog BOX SET PasswordSET System SET Unit IDEnter the Unit ID number 1-64, and then click OK System Communication Setup Dialog Box Set Time and Date Dialog Box SET Titles CM9760-CC1 CM9760-MDAPelco Manual C573M-D 11/03 Set Cable Compensation Dialog Box SET Display Position Text Dialog Box SET Message Text Message Text Editing Dialog BoxCommand Data Window Pelco Manual C573M-D 11/03 Sample Display Screen Example Sample Command Data Window Pelco Manual C573M-D 11/03 Send Data Video Alphanumeric OverlaysTroubleshooting Symptom Possible Problem Possible SolutionSpecifications General RatingsAppendix a Applications Simple System Configuration Shielded Twisted Pair RS-232 CM9760-MDA RS-422PV130 CM9760-CDU-TCM9760-CC1 Connection to up to 16 Daisy-Chained MDA Units COM1 COM2 MDA Connected to Multiplexers Non-Coaxitron System Setup = DataCoaxitron with System 9760 Setup Coaxitron with System 6800 Setup CM9760-MDA Message Text Sent from Third-Party Equipment Appendix B Supported Title and Message Text Characters AsteriskAppendix C Message Text Insertion Commands Command Function Command FormatPelco Manual C573M-D 11/03 Regulatory Notices Radio and Television InterferenceWarranty and Return Information Revision History