Pelco cs73m-d operation manual SET Message Text, Message Text Editing Dialog Box

Page 35

NOTE: A list of characters supported by the MDA for display of message text is provided in Appendix B.

NOTE: Positioning the title/ time/date text in the top or middle of the screen in the Position Text dialog box ensures that you will be able to view the message text that is displayed on a moni- tor. (For information about the Position Text dialog box, refer to the Set Display section of this manual.)

SET MESSAGE TEXT

The CM9760-MDA accepts message text to meet the needs of applications that require real-time information overlaid on the video being viewed. Up to five lines of message text can be sent to the MDA simultaneously. Each line can contain up to 24 alphanumeric characters. The message text can be inserted onto any MDA channel independently.

The CM9760-MDA Setup program provides a tool that demonstrates support of the message text feature of the MDA. The program allows message text to be sent from the PC to an MDA or to an MDA daisy chain. The PC application is designed as an example of message text operation for third parties who wish to develop their own message text interface to the MDA. (Refer to the Applications section of this manual for an application diagram and to Appendix C for a listing of the message text insertion commands supported by the MDA.)

To set message text using the CM9760-MDA Setup program, proceed as follows:

1.Open the Position Text dialog box and do the following:

a.Position the title/time/date text in the top or middle of the screen (the text should not be positioned at the bottom of the screen).

b.Close the Position Text dialog box.

2.Open the Message Text Editing dialog box by clicking Edit on the CM9760-MDA SETUP dialog box and then clicking Message Text. The Message Text Editing dialog box, Figure 31, appears.

Figure 31. Message Text Editing Dialog Box

3.Enter the Unit ID number (1-64) of the MDA unit for which you want to set message text, and then press Return. Note that all subsequent changes using the CM9760-MDA Setup program will be applied to the unit ID number that was entered.

4.Enter the channel (camera) number (1-16) for which you want to set message text, and then press Return. Note that all subsequent changes using the CM9760-MDA Setup program will be applied to the channel number that was entered.

34

 

Pelco Manual C573M-D (11/03)

 

 

 

Image 35
Contents Important Notice System Contents CM9760-CC1 Connection to over 16 MDA Units List of IllustrationsList of Tables Master MDA Time and Date Generator for 63 MDA Slave UnitsOverview Important Safeguards and WarningsDescription System Configuration Rear Panel View Communication Hardware SetupMounting ModelsSwitch Settings Port Setup Selected Communication Ports SetupCameras Address Setup for Daisy ChainingSwitch Settings Camera Range Selected Resetting to Factory Defaults Setting UP a Unit AS the Master ClockCable Type Maximum Distance Clearing TITLE/TIME/DATE Text Display on ALL ChannelsVideo Connections Data Connections Connecting the MDA to a System 9740/9760 ControllerTransmit Transmit + No Connection Ground Receive Receive + Connecting the MDA to AN External PCPin Out RS-232 Function RS-422 Function RS-485 Function Connecting the MDA to a KBD200A or KBD300A Keyboard Connecting the MDA to a CM9760-KBD KeyboardPower Connections Keyboard WiringProgramming with a Keyboard Time and Date SetupProgramming Programming MethodsÒhost Direct CAM CTRL.Ó Entering the Programming Mode with the CM9760-KBDSET Camera Title Main MenuSET Camera Display SET Cable CompensationDisplay Enable TimeEnable Video PositionTable E. CM9760-CC1/CM9760-MDA Format Matchup SET Time and DateDEC-31-02 115952 PMData Bits SET PortProtocol Baud RateParity Reset MDASystem Requirements Stop BitsInstalling the CM9760-MDA Setup Program Login Dialog Box Starting the CM9760-MDA Setup ProgramSET Password CM9760-MDA Setup Dialog BOXEnter the Unit ID number 1-64, and then click OK SET Unit IDSET System System Communication Setup Dialog Box Set Time and Date Dialog Box CM9760-CC1 CM9760-MDA SET TitlesPelco Manual C573M-D 11/03 Set Cable Compensation Dialog Box SET Display Position Text Dialog Box Message Text Editing Dialog Box SET Message TextCommand Data Window Pelco Manual C573M-D 11/03 Sample Display Screen Example Sample Command Data Window Pelco Manual C573M-D 11/03 Video Alphanumeric Overlays Send DataSymptom Possible Problem Possible Solution TroubleshootingSpecifications Ratings GeneralAppendix a Applications Simple System Configuration Shielded Twisted Pair RS-422 RS-232 CM9760-MDACM9760-CDU-T PV130CM9760-CC1 Connection to up to 16 Daisy-Chained MDA Units COM1 COM2 MDA Connected to Multiplexers = Data Non-Coaxitron System SetupCoaxitron with System 9760 Setup Coaxitron with System 6800 Setup CM9760-MDA Message Text Sent from Third-Party Equipment Asterisk Appendix B Supported Title and Message Text CharactersCommand Function Command Format Appendix C Message Text Insertion CommandsPelco Manual C573M-D 11/03 Radio and Television Interference Regulatory NoticesRevision History Warranty and Return Information