9.Enter and send message text to the selected unit and channel for the desired number of rows (as determined by the Rows to Display value set in step 7 above). For each row, the message text can contain a maximum number of 24 alphanumeric characters.

¥If the desired number of rows is 1, enter the message text into the Row 1 message text entry box and then click the Send Row 1 button.

¥If the desired number of rows is more than one, you can enter and send the message text for each row individually or you can enter the message text for all rows and then send the message text for all rows at one time:

ÐTo send the message text individually for each row, click the Send Row x button (x = 1, 2, 3, 4, or 5) as appropriate.

ÐTo send the message text for all rows at one time, click the Send Messages button.

The desired message text is displayed on the number of rows selected to display message text on the current MDA channel.

Pelco Manual C573M-D (11/03)

37

Image 38
Contents Important Notice System Contents Master MDA Time and Date Generator for 63 MDA Slave Units List of IllustrationsList of Tables CM9760-CC1 Connection to over 16 MDA UnitsOverview Important Safeguards and WarningsDescription System Configuration Rear Panel View Models Hardware SetupMounting CommunicationCommunication Ports Setup Switch Settings Port Setup SelectedCameras Address Setup for Daisy ChainingSwitch Settings Camera Range Selected Setting UP a Unit AS the Master Clock Resetting to Factory DefaultsCable Type Maximum Distance Clearing TITLE/TIME/DATE Text Display on ALL ChannelsVideo Connections Connecting the MDA to a System 9740/9760 Controller Data ConnectionsTransmit Transmit + No Connection Ground Receive Receive + Connecting the MDA to AN External PCPin Out RS-232 Function RS-422 Function RS-485 Function Connecting the MDA to a CM9760-KBD Keyboard Connecting the MDA to a KBD200A or KBD300A KeyboardKeyboard Wiring Power ConnectionsProgramming Methods Time and Date SetupProgramming Programming with a KeyboardEntering the Programming Mode with the CM9760-KBD Òhost Direct CAM CTRL.ÓMain Menu SET Camera TitleSET Cable Compensation SET Camera DisplayPosition Enable TimeEnable Video Display115952 PM SET Time and DateDEC-31-02 Table E. CM9760-CC1/CM9760-MDA Format MatchupBaud Rate SET PortProtocol Data BitsStop Bits Reset MDASystem Requirements ParityInstalling the CM9760-MDA Setup Program Starting the CM9760-MDA Setup Program Login Dialog BoxCM9760-MDA Setup Dialog BOX SET PasswordEnter the Unit ID number 1-64, and then click OK SET Unit IDSET System System Communication Setup Dialog Box Set Time and Date Dialog Box SET Titles CM9760-CC1 CM9760-MDAPelco Manual C573M-D 11/03 Set Cable Compensation Dialog Box SET Display Position Text Dialog Box SET Message Text Message Text Editing Dialog BoxCommand Data Window Pelco Manual C573M-D 11/03 Sample Display Screen Example Sample Command Data Window Pelco Manual C573M-D 11/03 Send Data Video Alphanumeric OverlaysTroubleshooting Symptom Possible Problem Possible SolutionSpecifications General RatingsAppendix a Applications Simple System Configuration Shielded Twisted Pair RS-232 CM9760-MDA RS-422PV130 CM9760-CDU-TCM9760-CC1 Connection to up to 16 Daisy-Chained MDA Units COM1 COM2 MDA Connected to Multiplexers Non-Coaxitron System Setup = DataCoaxitron with System 9760 Setup Coaxitron with System 6800 Setup CM9760-MDA Message Text Sent from Third-Party Equipment Appendix B Supported Title and Message Text Characters AsteriskAppendix C Message Text Insertion Commands Command Function Command FormatPelco Manual C573M-D 11/03 Regulatory Notices Radio and Television InterferenceWarranty and Return Information Revision History