Pelco cs73m-d operation manual Keyboard Wiring, Power Connections

Page 15

Keyboard Wiring

Refer to Figure 8.

1.Use the supplied keyboard data cable to connect the keyboard to the RJ-45 jack on the wall block.

2.Remove the RJ-45 plug from one end of a second keyboard data cable and strip the cable jacket back 2 inches (5 cm).

3.Hold up the end of the cable that has the RJ-45 plug still attached and examine the wire colors going to each pin. (Refer to the Òcheck wire colorsÓ detail in Figure 8.) Make note of the colors going to pins 7 and 8.

4.Connect the stripped wires to the wall block as follows:

Wire from RJ-45 pin 8 to wall block terminal 1;

Wire from RJ-45 pin 7 to wall block terminal 2;

Cut the unused wires back to the cable jacket.

5.Plug the RJ-45 end of the second (modified) keyboard data cable into the COM1 port on the master distribution amplifier.

6.Plug the KBDKIT or KBDKIT-X into a suitable outlet.

POWER CONNECTIONS

NOTE: Always replace blown fuses with fuses of the same rating. Failure to do so could result in serious damage to the unit.

The MDAÕs rear panel contains a three-pronged 120 VAC receptacle. Use the supplied power cord to connect the MDA to a power source.

 

CHECK WIRE COLORS DETAIL

 

RJ-45 PLUG

 

PIN 7

COM1

PIN 8

 

 

 

HOLD WITH

 

 

LOCKING CLIP

 

 

ON BOTTOM

FROM PIN 7

FROM PIN 8

TO WALL BLOCK

 

 

 

TERMINALS

4

5

PIN 1

KBD200A

36

TXÐ

2

7

TX+

1

8

12 VAC

KBDKIT OR

25-FOOT KEYBOARD

KBDKIT-X

DATA CABLE

 

Figure 8. CM9760-MDA Keyboard Wiring

14

Pelco Manual C573M-D (11/03)

Image 15
Contents Important Notice System Contents CM9760-CC1 Connection to over 16 MDA Units List of IllustrationsList of Tables Master MDA Time and Date Generator for 63 MDA Slave UnitsImportant Safeguards and Warnings DescriptionOverview System Configuration Rear Panel View Communication Hardware SetupMounting ModelsSwitch Settings Port Setup Selected Communication Ports SetupAddress Setup for Daisy Chaining Switch Settings Camera Range SelectedCameras Resetting to Factory Defaults Setting UP a Unit AS the Master ClockClearing TITLE/TIME/DATE Text Display on ALL Channels Video ConnectionsCable Type Maximum Distance Data Connections Connecting the MDA to a System 9740/9760 ControllerConnecting the MDA to AN External PC Pin Out RS-232 Function RS-422 Function RS-485 FunctionTransmit Transmit + No Connection Ground Receive Receive + Connecting the MDA to a KBD200A or KBD300A Keyboard Connecting the MDA to a CM9760-KBD KeyboardPower Connections Keyboard WiringProgramming with a Keyboard Time and Date SetupProgramming Programming MethodsÒhost Direct CAM CTRL.Ó Entering the Programming Mode with the CM9760-KBDSET Camera Title Main MenuSET Camera Display SET Cable CompensationDisplay Enable TimeEnable Video PositionTable E. CM9760-CC1/CM9760-MDA Format Matchup SET Time and DateDEC-31-02 115952 PMData Bits SET PortProtocol Baud RateParity Reset MDASystem Requirements Stop BitsInstalling the CM9760-MDA Setup Program Login Dialog Box Starting the CM9760-MDA Setup ProgramSET Password CM9760-MDA Setup Dialog BOXSET Unit ID SET SystemEnter the Unit ID number 1-64, and then click OK System Communication Setup Dialog Box Set Time and Date Dialog Box CM9760-CC1 CM9760-MDA SET TitlesPelco Manual C573M-D 11/03 Set Cable Compensation Dialog Box SET Display Position Text Dialog Box Message Text Editing Dialog Box SET Message TextCommand Data Window Pelco Manual C573M-D 11/03 Sample Display Screen Example Sample Command Data Window Pelco Manual C573M-D 11/03 Video Alphanumeric Overlays Send DataSymptom Possible Problem Possible Solution TroubleshootingSpecifications Ratings GeneralAppendix a Applications Simple System Configuration Shielded Twisted Pair RS-422 RS-232 CM9760-MDACM9760-CDU-T PV130CM9760-CC1 Connection to up to 16 Daisy-Chained MDA Units COM1 COM2 MDA Connected to Multiplexers = Data Non-Coaxitron System SetupCoaxitron with System 9760 Setup Coaxitron with System 6800 Setup CM9760-MDA Message Text Sent from Third-Party Equipment Asterisk Appendix B Supported Title and Message Text CharactersCommand Function Command Format Appendix C Message Text Insertion CommandsPelco Manual C573M-D 11/03 Radio and Television Interference Regulatory NoticesRevision History Warranty and Return Information