Pelco cs73m-d Entering the Programming Mode with the CM9760-KBD, Òhost Direct CAM CTRL.Ó

Page 17

NOTE: You need a pass- word to enter setup mode on the CM9760-KBD key- board. The default, as set from the factory, is 1234.

ENTERING THE PROGRAMMING MODE WITH THE CM9760-KBD

Use the CM9760-KBD keyboard to program the titles, time, date, and setup of the ports.

1.To enter programming mode from the keyboard, you must first enter the setup mode for the keyboard. Attach a straight power cable from COM 1 on the rear of keyboard to the power supply. (The LCD displays the keyboard offline message.)

2.Set DIP switch 2 (on the underside of the CM9760-KBD) to ON.

3.You are prompted to enter the setup PIN. (The factory default is 1234.) Do so, and the main setup mode menu appears.

4.Press the blue button beneath the ADV icon. The Advance Setup 1 screen appears.

5.You have to set the KBD in direct mode. To do so, cycle the host type by pressing the blue buttons below the left and right arrow icons (<= and =>) until the LCD shows

ÒHOST DIRECT CAM CTRL.Ó

6.Press the blue button beneath the Step Forward icon (hand that points down) to go to the next line. Change the baud rate from 4800 to 9600 by pressing the blue button beneath the right arrow icon.

7.Press the blue button beneath the SAVE icon.

8.Press the blue button beneath the exit icon (an open door).

9.Press the blue button beneath the camera icon.

10.Press the blue button beneath the Step Forward icon (hand pointing down) four times.

11.You need to define a camera. You are currently on physical 0, logical 0. You need to change the logical to 1.

a.Press the blue button beneath the DEF NUM icon (this reverses videos).

b.Press 1.

c.Press the blue button beneath the DEF NUM icon. Physical 0 should now have a logical 1.

d.Press the blue button beneath the SAVE icon.

12.Press the blue button beneath the exit icon (an open door) twice.

13.You are prompted to turn off DIP switch 2. Do so.

14.Connect a reversed cable from the power supply to COM 1 on the rear of the MDA.

15.Access the main programming menu by moving the joystick in any direction (see Figure 9, Main Menu). You can now begin programming.

16.When you finish programming, select EXIT from the Main Menu. Then disconnect the keyboard to exit programming mode.

ENTERING THE PROGRAMMING MODE WITH THE KBD200A OR KBD300A KEYBOARD

1.Access the main programming menu by moving the joystick in any direction (KBD300A) or by pressing any pan/tilt key (KBD200A) (see Figure 9, Main Menu). You can now begin programming.

2.When you finish programming, select EXIT from the Main Menu. Then disconnect the keyboard to fully exit the programming mode.

16

Pelco Manual C573M-D (11/03)

Image 17
Contents Important Notice System Contents List of Tables List of IllustrationsMaster MDA Time and Date Generator for 63 MDA Slave Units CM9760-CC1 Connection to over 16 MDA UnitsOverview Important Safeguards and WarningsDescription System Configuration Rear Panel View Mounting Hardware SetupModels CommunicationSwitch Settings Port Setup Selected Communication Ports SetupCameras Address Setup for Daisy ChainingSwitch Settings Camera Range Selected Resetting to Factory Defaults Setting UP a Unit AS the Master ClockCable Type Maximum Distance Clearing TITLE/TIME/DATE Text Display on ALL ChannelsVideo Connections Data Connections Connecting the MDA to a System 9740/9760 ControllerTransmit Transmit + No Connection Ground Receive Receive + Connecting the MDA to AN External PCPin Out RS-232 Function RS-422 Function RS-485 Function Connecting the MDA to a KBD200A or KBD300A Keyboard Connecting the MDA to a CM9760-KBD KeyboardPower Connections Keyboard WiringProgramming Time and Date SetupProgramming Methods Programming with a KeyboardÒhost Direct CAM CTRL.Ó Entering the Programming Mode with the CM9760-KBDSET Camera Title Main MenuSET Camera Display SET Cable CompensationEnable Video Enable TimePosition DisplayDEC-31-02 SET Time and Date115952 PM Table E. CM9760-CC1/CM9760-MDA Format MatchupProtocol SET PortBaud Rate Data BitsSystem Requirements Reset MDAStop Bits ParityInstalling the CM9760-MDA Setup Program Login Dialog Box Starting the CM9760-MDA Setup ProgramSET Password CM9760-MDA Setup Dialog BOXEnter the Unit ID number 1-64, and then click OK SET Unit IDSET System System Communication Setup Dialog Box Set Time and Date Dialog Box CM9760-CC1 CM9760-MDA SET TitlesPelco Manual C573M-D 11/03 Set Cable Compensation Dialog Box SET Display Position Text Dialog Box Message Text Editing Dialog Box SET Message TextCommand Data Window Pelco Manual C573M-D 11/03 Sample Display Screen Example Sample Command Data Window Pelco Manual C573M-D 11/03 Video Alphanumeric Overlays Send DataSymptom Possible Problem Possible Solution TroubleshootingSpecifications Ratings GeneralAppendix a Applications Simple System Configuration Shielded Twisted Pair RS-422 RS-232 CM9760-MDACM9760-CDU-T PV130CM9760-CC1 Connection to up to 16 Daisy-Chained MDA Units COM1 COM2 MDA Connected to Multiplexers = Data Non-Coaxitron System SetupCoaxitron with System 9760 Setup Coaxitron with System 6800 Setup CM9760-MDA Message Text Sent from Third-Party Equipment Asterisk Appendix B Supported Title and Message Text CharactersCommand Function Command Format Appendix C Message Text Insertion CommandsPelco Manual C573M-D 11/03 Radio and Television Interference Regulatory NoticesRevision History Warranty and Return Information